參考文獻 |
[1] 李宏仁,“鋼筋混凝土耐震梁柱接頭剪力強度之研究”,博士論文,國立台灣科技大學營建工程研究所,台北,民國89年5月(2000)。
[2] ACI Committee 318, “Building Code Requirements for Structure Concrete (ACI 318-99) and Commentary (ACI 318R-99),” American Concrete Institute, Farmington Hills,1999.
[3] Vecchio, F. J., and Collins, M. P.,“Compression Response of Cracked Reinforced Concrete, ” Journal of Structural Engineering,ASCE,Vol.119,NO.12,December 1993,pp.3590-3610.
[4] Zhang, L. X., and Hsu, T. T. C.,“Behavior and Analysis of 100Mpa Concrete Membrane Elements, ” Journal of Structural Engineering , ASCE, Vol.124, NO.1,January 1998,pp.24-34.
[5] Schäfer, K.,“Strut-and-Tie Models for the Design of Structural Concrete, ” Notes of Workshop, Department of Civil Engineering ,National Cheng Kung University,Tainan ,
Taiwan,March 1998,140pp.
[6] Paulay, T., and Priestley, M. J N., Seismic Design of Reinforced Concrete and Masonry of Buildings, John Wiley&Sons,1992,744pp.
[7] 黃世建、王國州、李宏仁,“鋼筋混凝土梁柱接頭之耐震設計與補強策略”,研討會手稿,台北,民國90年10月(2001)。
[8] Hakuto, S., Park, R., and Tanaka, H., 1995, Retrofitting of Reinforced Concrete Moment Resisting Frame, Research Report 95-4, Department of Civil Engineering, University of Canterbury, Christchurch, 390pp.
[9] Park, R.,“Seismic Assessment and Retrofit of Concrete Structures-Unites States and New Zealand Development” ,Proceedings of Technical Conference of New Zealand Concrete Society,Wairakei,1992,pp18-25.
[10] Sergio M.Alcocer and James O. Jirsa, “Strength of Rinforced Concrete Frame Connections Rehabilitated by Jacketing “ ACI Structural Journal, V. 90, No. 3, May.-June. 1993, pp. 248-261.
[11] GHOBARAH,A., Aziz,Tarek S.and Biddah Ashraf“SEISMIC REHABILITATION ”,Journal of Earthquake Engineering, Vol. 5, No 1(2001).
[12] 林恭弘,“梁柱接頭FRP補強研究”,碩士論文,國立台灣大學土木工程學研究所,台北,民國89年六月(2000).
[13] Liu,A.and Park,R.,“Seismic Behaviour And Retrofit Of Pre-1970s As-Built Exterior Beam-Column Joints Reinforced By Plain Bars”,Bulletin of the New Zealand National Society for Earthquake Engineering.
[14] GHOBARAH,A.and SAID,1.,“SEISMIC REHABILITATION OF BEAM-COLUMN JIONTS USING FRP LAMINATES”,Journal of Earthquake Engineering, Vol. 5, No 1(2001).
[15] Park, R., and Milburn, J. R.,”Comparison of Recent New Zealand and United States Seismic Design Provisions for Reinforced Concrete Beam-Column Joints and Test Results for Four Units Designed According to the New Zealand Code,” Bulletin of the New Zealand National Society for Earthquake Engineering, Vol. 16, No 1, March 1983, pp. 21-42.
[16] Uniform Building Code, International Conference of Building Officials, Whittier, California,1997.
[17] 高啟洲,“非韌性混凝土梁柱內接頭補強之研究”,碩士論文初稿,國立中央大學土木工程學研究所,民國91年七月(2002).
[18] ACI-ASCE Committee 352, “Recommendations for Design of Beam-Column Joints in Monolithic Reinforced Concrete Structures,”ACI Journal, Proceeding, Vol. 82, No. 3, May-June 1985, pp. 266-283.
[19]Hwang, S. J., and Lee, H. J.,“Strength Prediction for Discontinuity Regions by Softened Strut-and-Tie Model, ” Journal of Structural Engineering , ASCE, 2002, in press |