參考文獻 |
[1] C. C. Burt and J. E. Arrowsmith, "Respiratory failure," Surgery (Oxford), vol. 27, no. 11, pp. 475-479 %@ 0263-9319, 2009.
[2] A. Tulaimat, A. Patel, M. Wisniewski, and R. Gueret, "The validity and reliability of the clinical assessment of increased work of breathing in acutely ill patients," Journal of critical care, vol. 34, pp. 111-115 %@ 0883-9441, 2016.
[3] N. M. Punjabi, "The epidemiology of adult obstructive sleep apnea," Proceedings of the American Thoracic Society, vol. 5, no. 2, pp. 136-143 %@ 1546-3222, 2008.
[4] J. A. Luis et al., "Design and implementation of a smart sensor for respiratory rate monitoring," Sensors, vol. 14, no. 2, pp. 3019-3032, 2014.
[5] R. D. Allison, E. L. Holmes, and J. Nyboer, "Volumetric dynamics of respiration as measured by electrical impedance plethysmography," Journal of applied physiology, vol. 19, no. 1, pp. 166-173 %@ 8750-7587, 1964.
[6] K. Ashutosh, R. Gilbert, J. H. Auchincloss, J. Erlebacher, and D. Peppi, "Impedance pneumograph and magnetometer methods for monitoring tidal volume," Journal of applied physiology, vol. 37, no. 6, pp. 964-966 %@ 8750-7587, 1974.
[7] F.-T. Wang, H.-L. Chan, C.-L. Wang, H.-M. Jian, and S.-H. Lin, "Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition," Sensors, vol. 15, no. 7, pp. 16372-16387, 2015.
[8] X. Li, D. Qiao, Y. Li, and H. Dai, "A novel through-wall respiration detection algorithm using uwb radar," in Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE, 2013, pp. 1013-1016: IEEE.
[9] B. A. Reyes, N. Reljin, Y. Kong, Y. Nam, and K. H. Chon, "Tidal volume and instantaneous respiration rate estimation using a volumetric surrogate signal acquired via a smartphone camera," IEEE journal of biomedical and health informatics, vol. 21, no. 3, pp. 764-777, 2017.
[10] Y. Xin, X. Qi, C. Qian, H. Tian, Z. Ling, and Z. Jiang, "A Wearable Respiration and Pulse Monitoring System Based on PVDF Piezoelectric Film," Integrated Ferroelectrics, vol. 158, no. 1, pp. 43-51, 2014.
[11] G. B. Moody et al., "Clinical validation of the ECG-derived respiration (EDR) technique," Group, vol. 1, no. 3, 1986.
[12] L. G. Lindberg, H. Ugnell, and P. Öberg, "Monitoring of respiratory and heart rates using a fibre-optic sensor," Medical and Biological Engineering and Computing, vol. 30, no. 5, pp. 533-537 %@ 0140-0118, 1992.
[13] K. Nakajima, T. Tamura, and H. Miike, "Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique," Medical engineering & physics, vol. 18, no. 5, pp. 365-372 %@ 1350-4533, 1996.
[14] H. Kim, J.-Y. Kim, and C.-H. Im, "Fast and Robust Real-Time Estimation of Respiratory Rate from Photoplethysmography," Sensors, vol. 16, no. 9, p. 1494, 2016.
[15] J. Lázaro, Y. Nam, E. Gil, P. Laguna, and K. H. Chon, "Respiratory rate derived from smartphone-camera-acquired pulse photoplethysmographic signals," Physiological measurement, vol. 36, no. 11, p. 2317, 2015.
[16] J. Lee and K. H. Chon, "Time-varying autoregressive model-based multiple modes particle filtering algorithm for respiratory rate extraction from pulse oximeter," IEEE Transactions on Biomedical Engineering, vol. 58, no. 3, pp. 790-794, 2011.
[17] J. P. Dieffenderfer et al., "Wearable wireless sensors for chronic respiratory disease monitoring," 2015, pp. 1-6 %@ 1467372013: IEEE.
[18] N. E. Almond and E. D. Cooke, "Observations on the photoplethysmograph pulse derived from a laser Doppler flowmeter," Clinical Physics and Physiological Measurement, vol. 10, no. 2, pp. 137 %@ 0143-0815, 1989.
[19] A. V. J. Challoner, "Photoelectric plethysmography for estimating cutaneous blood flow," Non-invasive physiological measurements, vol. 1, pp. 125-151, 1979.
[20] J. C. Dorlas and J. A. Nijboer, "PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIA Application and Interpretation," British journal of anaesthesia, vol. 57, no. 5, pp. 524-530 %@ 0007-0912, 1985.
[21] A. A. R. Kamal, J. B. Harness, G. Irving, and A. J. Mearns, "Skin photoplethysmography—a review," Computer methods and programs in biomedicine, vol. 28, no. 4, pp. 257-269 %@ 0169-2607, 1989.
[22] J. Penaz, "Mayer waves: history and methodology," Automedica, vol. 2, no. 3, pp. 135-142, 1978.
[23] A. Colantuoni, S. Bertuglia, and M. Intaglietta, "Quantitation of rhythmic diameter changes in arterial microcirculation," American Journal of Physiology-Heart and Circulatory Physiology, vol. 246, no. 4, pp. H508-H517 %@ 0363-6135, 1984.
[24] N. E. Huang, M.-T. Lo, W. U. Zhao-Hua, and C. Xian-Yao, "Method for quantifying and modeling degree of nonlinearity, combined nonlinearity, and nonstationarity," ed: Google Patents, 2014.
[25] N. E. Huang et al., "The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis," 1998, vol. 454, pp. 903-995 %@ 1364-5021: The Royal Society.
[26] M. Blanco-Velasco, B. Weng, and K. E. Barner, "ECG signal denoising and baseline wander correction based on the empirical mode decomposition," Computers in biology and medicine, vol. 38, no. 1, pp. 1-13 %@ 0010-4825, 2008.
[27] Z.-F. Liu, Z.-P. Liao, and E.-F. Sang, "Speech enhancement based on Hilbert-Huang transform," 2005, vol. 8, pp. 4908-4912 %@ 0780390911: IEEE.
[28] P. A. Hwang, N. E. Huang, and D. W. Wang, "A note on analyzing nonlinear and nonstationary ocean wave data," Applied Ocean Research, vol. 25, no. 4, pp. 187-193 %@ 0141-1187, 2003.
[29] K. T. Coughlin and K.-K. Tung, "11-year solar cycle in the stratosphere extracted by the empirical mode decomposition method," Advances in space research, vol. 34, no. 2, pp. 323-329 %@ 0273-1177, 2004.
[30] B. Prathyusha, T. S. Rao, and D. Asha, "Extraction of respiratory rate from PPG signals using PCA and EMD," International Journal of Research in Engineering and Technology, vol. 1, no. 2, pp. 164-184, 2012.
[31] N. E. Huang et al., "On Holo-Hilbert spectral analysis: a full informational spectral representation for nonlinear and non-stationary data," Phil. Trans. R. Soc. A, vol. 374, no. 2065, pp. 20150206 %@ 1364-503X, 2016.
[32] P. S. Addison, J. N. Watson, M. L. Mestek, and R. S. Mecca, "Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study," Journal of clinical monitoring and computing, vol. 26, no. 1, pp. 45-51 %@ 1387-1307, 2012.
[33] E. Marey, "Physiologie Experimentale, ii, 74," 1876.
[34] T. Pereira, C. Correia, and J. Cardoso, "Novel methods for pulse wave velocity measurement," Journal of medical and biological engineering, vol. 35, no. 5, pp. 555-565, 2015.
[35] A. F. Pacela, "Impedance pneumography—A survey of instrumentation techniques," Medical and biological engineering, vol. 4, no. 1, pp. 1-15, 1966.
[36] K. Pilt, K. Meigas, R. Ferenets, K. Temitski, and M. Viigimaa, "Photoplethysmographic signal waveform index for detection of increased arterial stiffness," Physiological measurement, vol. 35, no. 10, p. 2027, 2014.
[37] J. M. Bland and D. Altman, "Statistical methods for assessing agreement between two methods of clinical measurement," The lancet, vol. 327, no. 8476, pp. 307-310 %@ 0140-6736, 1986.
[38] A. I. Krupatkin, "Blood flow oscillations at a frequency of about 0.1 Hz in skin microvessels do not reflect the sympathetic regulation of their tone," Human physiology, vol. 35, no. 2, pp. 183-191 %@ 0362-1197, 2009.
[39] A. Sobron, I. Romero, and T. Lopetegi, "Evaluation of methods for estimation of respiratory frequency from the ECG," in Computing in Cardiology, 2010, 2010, pp. 513-516: IEEE.
[40] A. E. Awodeyi, S. R. Alty, and M. Ghavami, "Median Based Method for Baseline Wander Removal in Photoplethysmogram Signals," in Bioinformatics and Bioengineering (BIBE), 2014 IEEE International Conference on, 2014, pp. 311-314: IEEE.
[41] K. Duan, Y. Hu, Z. Qian, and G. Wang, "An FPGA-based morphological filter for baseline wandering correction in photoplethysmography," in Biomedical Circuits and Systems Conference (BioCAS), 2016 IEEE, 2016, pp. 216-219: IEEE.
[42] A. K. Bhoi, K. S. Sherpa, J. S. Tamang, D. Phurailatpam, and A. K. Gupta, "Real time acquisition and analysis of PCG and PPG signals," in Communications and Signal Processing (ICCSP), 2015 International Conference on, 2015, pp. 0062-0065: IEEE.
[43] K. E. Barrett, S. M. Barman, S. Boitano, and H. Brooks, "Ganong’s review of medical physiology. 23," NY: McGraw-Hill Medical, 2009.
[44] L. Nilsson, T. Goscinski, S. Kalman, L. G. Lindberg, and A. Johansson, "Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjects," Acta Anaesthesiologica Scandinavica, vol. 51, no. 9, pp. 1250-1257 %@ 1399-6576, 2007.
[45] P. D. Larsen, M. Harty, M. Thiruchelvam, and D. C. Galletly, "Spectral analysis of AC and DC components of the pulse photoplethysmograph at rest and during induction of anaesthesia," International journal of clinical monitoring and computing, vol. 14, no. 2, pp. 89-95 %@ 0167-9945, 1997.
[46] L. Bernardi et al., "Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves," Clinical science, vol. 90, no. 5, pp. 345-355 %@ 0143-5221, 1996.
[47] Y. Mendelson and B. D. Ochs, "Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography," IEEE Transactions on Biomedical Engineering, vol. 35, no. 10, pp. 798-805 %@ 0018-9294, 1988.
[48] V. Lesauskaite and M. J. Ebejer, "Age-related changes in the respiratory system," 1999.
[49] E. K. Verbeken, M. Cauberghs, I. Mertens, J. Clement, J. M. Lauweryns, and K. P. Van de Woestijne, "The senile lung: comparison with normal and emphysematous lungs 1. Structural aspects," Chest, vol. 101, no. 3, pp. 793-799 %@ 0012-3692, 1992.
[50] E. Puchelle, J. M. Zahm, and A. Bertrand, "Influence of age on bronchial mucociliary transport," Scandinavian journal of respiratory diseases, vol. 60, no. 6, pp. 307-313 %@ 0036-5572, 1979.
[51] P. J. Gallagher and A. C. van der Wal, "Histology for pathologists," in Blood vessels, ed: Raven New York, 1997, pp. 763-83.
[52] M. Ermini, "Ageing changes in mammalian skeletal muscle," Gerontology, vol. 22, no. 4, pp. 301-316 %@ 0304-324X, 1976.
[53] D. D. Peterson and A. P. Fishman, "The lungs in later life," Pulmonary disease and disorders: update, vol. 1, pp. 123-36, 1982.
[54] N. B. Pride, "Pulmonary distensibility in age and disease," Bulletin de physio-pathologie respiratoire, vol. 10, no. 1, pp. 103-108 %@ 0007-439X, 1973.
[55] D. L. Sherrill, M. D. Lebowitz, R. J. Knudson, and B. Burrows, "Smoking and Symptom Effects on the Curves of Lung Function Growth and Decline1-3," 1991.
[56] J. P. McFadden, R. C. Price, H. D. Eastwood, and R. S. Briggs, "Raised respiratory rate in elderly patients: a valuable physical sign," Br Med J (Clin Res Ed), vol. 284, no. 6316, pp. 626-627 %@ 0267-0623, 1982.
[57] M. P. Tulppo, T. H. Mäkikallio, T. Seppänen, R. T. Laukkanen, and H. V. Huikuri, "Vagal modulation of heart rate during exercise: effects of age and physical fitness," American Journal of Physiology-Heart and Circulatory Physiology, vol. 274, no. 2, pp. H424-H429, 1998.
[58] C. D. B. Luft and J. Bhattacharya, "Aroused with heart: modulation of heartbeat evoked potential by arousal induction and its oscillatory correlates," Scientific reports, vol. 5, p. 15717, 2015.
[59] B. T. Paul, I. C. Bruce, D. J. Bosnyak, D. C. Thompson, and L. E. Roberts, "Modulation of electrocortical brain activity by attention in individuals with and without tinnitus," Neural plasticity, vol. 2014, 2014. |