參考文獻 |
[1] Nachiket. "Global Surgical Robots for the Spine Industry Trend, Growth, Shares, Strategy and Forecasts 2016 to 2022." (accessed.
[2] L. Yu, X. Chen, A. Margalit, H. Peng, G. Qiu, and W. Qian, "Robot‐assisted vs freehand pedicle screw fixation in spine surgery–a systematic review and a meta‐analysis of comparative studies," The International Journal of Medical Robotics and Computer Assisted Surgery, vol. 14, no. 3, p. e1892, 2018.
[3] D. P. Devito et al., "Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study," Spine, vol. 35, no. 24, pp. 2109-2115, 2010.
[4] M. Shoham et al., "Robotic assisted spinal surgery–from concept to clinical practice," Computer Aided Surgery, vol. 12, no. 2, pp. 105-115, 2007.
[5] K. Cahill and M. Wang, "Evaluating the accuracy of robotic assistance in spine surgery," Neurosurgery, vol. 71, no. 2, pp. N20-N21, 2012.
[6] S. C. Overley, S. K. Cho, A. I. Mehta, and P. M. Arnold, "Navigation and robotics in spinal surgery: where are we now?," Neurosurgery, vol. 80, no. 3S, pp. S86-S99, 2017.
[7] V. Kosmopoulos and C. Schizas, "Pedicle screw placement accuracy: a meta-analysis," Spine, vol. 32, no. 3, pp. E111-E120, 2007.
[8] T. Tjardes et al., "Image-guided spine surgery: state of the art and future directions," European spine journal, vol. 19, no. 1, pp. 25-45, 2010.
[9] A. R. Lanfranco, A. E. Castellanos, J. P. Desai, and W. C. Meyers, "Robotic surgery: a current perspective," Annals of surgery, vol. 239, no. 1, p. 14, 2004.
[10] J. Singh, E. R. Podolsky, A. E. Castellanos, and D. E. Stein, "Optimizing single port surgery: a case report and review of technique in colon resection," The International Journal of Medical Robotics and Computer Assisted Surgery, vol. 7, no. 2, pp. 127-130, 2011.
[11] L. Lenfant, S. Kim, A. Aminsharifi, G. Sawczyn, and J. Kaouk, "Floating docking technique: a simple modification to improve the working space of the instruments during single-port robotic surgery," World Journal of Urology, vol. 39, no. 4, pp. 1299-1305, 2021.
[12] M. T. V. Gomes, A. M. N. Machado, S. Podgaec, and G. A. S. Barison, "Initial experience with single-port robotic hysterectomy," Einstein (Sao Paulo), vol. 15, no. 4, pp. 476-480, 2017.
[13] R. W. Dobbs, W. R. Halgrimson, S. Talamini, H. T. Vigneswaran, J. O. Wilson, and S. Crivellaro, "Single-port robotic surgery: the next generation of minimally invasive urology," World journal of urology, vol. 38, no. 4, pp. 897-905, 2020.
[14] L. F. Grochola, C. Soll, A. Zehnder, R. Wyss, P. Herzog, and S. Breitenstein, "Robot-assisted versus laparoscopic single-incision cholecystectomy: results of a randomized controlled trial," Surgical endoscopy, vol. 33, no. 5, pp. 1482-1490, 2019.
[15] F. Shweikeh et al., "Robotics and the spine: a review of current and ongoing applications," Neurosurgical focus, vol. 36, no. 3, p. E10, 2014.
[16] S. R. Kantelhardt, R. Martinez, S. Baerwinkel, R. Burger, A. Giese, and V. Rohde, "Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement," European Spine Journal, vol. 20, no. 6, pp. 860-868, 2011.
[17] S. R. Schroerlucke et al., "Complication rate in robotic-guided vs fluoro-guided minimally invasive spinal fusion surgery: report from MIS refresh prospective comparative study," The Spine Journal, vol. 17, no. 10, pp. S254-S255, 2017.
[18] M. D’Souza, J. Gendreau, A. Feng, L. H. Kim, A. L. Ho, and A. Veeravagu, "Robotic-assisted spine surgery: history, efficacy, cost, and future trends," Robotic Surgery: Research and Reviews, vol. 6, p. 9, 2019.
[19] X. Hu, D. D. Ohnmeiss, and I. H. Lieberman, "Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients," European Spine Journal, vol. 22, no. 3, pp. 661-666, 2013.
[20] D. J. Podolsky, A. R. Martin, C. M. Whyne, E. M. Massicotte, M. R. Hardisty, and H. J. Ginsberg, "Exploring the role of 3-dimensional simulation in surgical training: feedback from a pilot study," Clinical Spine Surgery, vol. 23, no. 8, pp. e70-e74, 2010.
[21] N.-F. Tian et al., "Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies," European Spine Journal, vol. 20, no. 6, pp. 846-859, 2011.
[22] X. Le et al., "Robot-assisted versus fluoroscopy-assisted cortical bone trajectory screw instrumentation in lumbar spinal surgery: a matched-cohort comparison," World neurosurgery, vol. 120, pp. e745-e751, 2018.
[23] J.-Q. Wang et al., "Percutaneous sacroiliac screw placement: a prospective randomized comparison of robot-assisted navigation procedures with a conventional technique," Chinese medical journal, vol. 130, no. 21, p. 2527, 2017.
[24] N. Lonjon, E. Chan-Seng, V. Costalat, B. Bonnafoux, M. Vassal, and J. Boetto, "Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis," European Spine Journal, vol. 25, no. 3, pp. 947-955, 2016.
[25] N. Keric et al., "Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws," Neurosurgical focus, vol. 42, no. 5, p. E11, 2017.
[26] H.-J. Kim et al., "Biomechanical advantages of robot-assisted pedicle screw fixation in posterior lumbar interbody fusion compared with freehand technique in a prospective randomized controlled trial—perspective for patient-specific finite element analysis," The Spine Journal, vol. 17, no. 5, pp. 671-680, 2017.
[27] W. Sukovich, S. Brink‐Danan, and M. Hardenbrook, "Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist®," The International Journal of Medical Robotics and Computer Assisted Surgery, vol. 2, no. 2, pp. 114-122, 2006.
[28] J. M. Hicks, A. Singla, F. H. Shen, and V. Arlet, "Complications of pedicle screw fixation in scoliosis surgery: a systematic review," Spine, vol. 35, no. 11, pp. E465-E470, 2010.
[29] Y. Barzilay, M. Liebergall, A. Fridlander, and N. Knoller, "Miniature robotic guidance for spine surgery—introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres," The International Journal of Medical Robotics and Computer Assisted Surgery, vol. 2, no. 2, pp. 146-153, 2006.
[30] D.-Y. Kim, S.-H. Lee, S. K. Chung, and H.-Y. Lee, "Comparison of multifidus muscle atrophy and trunk extension muscle strength: percutaneous versus open pedicle screw fixation," Spine, vol. 30, no. 1, pp. 123-129, 2005.
[31] N. Bronsard et al., "Comparison between percutaneous and traditional fixation of lumbar spine fracture: intraoperative radiation exposure levels and outcomes," Orthopaedics & Traumatology: Surgery & Research, vol. 99, no. 2, pp. 162-168, 2013.
[32] N. Amoretti et al., "Percutaneous screw fixation of a vertebral pedicle fracture under CT-guidance: A new technique," European journal of radiology, vol. 81, no. 3, pp. 591-593, 2012.
[33] T. M. Heintel et al., "How safe is minimally invasive pedicle screw placement for treatment of thoracolumbar spine fractures?," European Spine Journal, vol. 26, no. 5, pp. 1515-1524, 2017.
[34] N. Moussazadeh, D. G. Rubin, L. McLaughlin, E. Lis, M. H. Bilsky, and I. Laufer, "Short-segment percutaneous pedicle screw fixation with cement augmentation for tumor-induced spinal instability," The Spine Journal, vol. 15, no. 7, pp. 1609-1617, 2015.
[35] T. M. Chapman, D. J. Blizzard, and C. R. Brown, "CT accuracy of percutaneous versus open pedicle screw techniques: a series of 1609 screws," European spine journal, vol. 25, no. 6, pp. 1781-1786, 2016.
[36] P. J. Belmont Jr, W. R. Klemme, A. Dhawan, and D. W. Polly Jr, "In vivo accuracy of thoracic pedicle screws," Spine, vol. 26, no. 21, pp. 2340-2346, 2001.
[37] R. J. Mobbs and D. A. Raley, "Complications with K-wire insertion for percutaneous pedicle screws," Clinical Spine Surgery, vol. 27, no. 7, pp. 390-394, 2014.
[38] K. Ishii et al., "A novel percutaneous guide wire (S-Wire) for percutaneous pedicle screw insertion: its development, efficacy, and safety," Surgical innovation, vol. 22, no. 5, pp. 469-473, 2015.
[39] D. A. Raley and R. J. Mobbs, "Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates," Spine, vol. 37, no. 12, pp. 1092-1100, 2012.
[40] H. M. Macdonald, K. K. Nishiyama, J. Kang, D. A. Hanley, and S. K. Boyd, "Age‐related patterns of trabecular and cortical bone loss differ between sexes and skeletal sites: a population‐based HR‐pQCT study," Journal of Bone and Mineral Research, vol. 26, no. 1, pp. 50-62, 2011.
[41] Y. R. Rampersaud, D. A. Simon, and K. T. Foley, "Accuracy requirements for image-guided spinal pedicle screw placement," Spine, vol. 26, no. 4, pp. 352-359, 2001.
[42] T. Hamasaki, N. Tanaka, J. Kim, M. Okada, M. Ochi, and W. C. Hutton, "Pedicle screw augmentation with polyethylene tape: a biomechanical study in the osteoporotic thoracolumbar spine," Clinical Spine Surgery, vol. 23, no. 2, pp. 127-132, 2010.
[43] H. Paik, D. G. Kang, R. A. Lehman Jr, R. E. Gaume, D. V. Ambati, and A. E. Dmitriev, "The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?," The Spine Journal, vol. 13, no. 11, pp. 1617-1626, 2013.
[44] X. L. Chong, A. Kumar, E. W. R. Yang, A.-K. Kaliya-Perumal, and J. Y.-L. Oh, "Incidence of pedicle breach following open and minimally invasive spinal instrumentation: A postoperative CT analysis of 513 pedicle screws applied under fluoroscopic guidance," BioMedicine, vol. 10, no. 2, p. 30, 2020.
[45] N. Acar, A. Karakasli, A. A. Karaarslan, M. H. Ozcanhan, F. Ertem, and M. Erduran, "The mechanical effect of rod contouring on rod-screw system strength in spine fixation," Journal of Korean Neurosurgical Society, vol. 59, no. 5, p. 425, 2016.
[46] E. B. Harris, P. Massey, J. Lawrence, J. Rihn, A. Vaccaro, and D. G. Anderson, "Percutaneous techniques for minimally invasive posterior lumbar fusion," Neurosurgical focus, vol. 25, no. 2, p. E12, 2008.
[47] X. Li et al., "Marked Guidewire Technique Prevents Complications of Percutaneous Pedicle Screws and Precisely Controls Depth," World neurosurgery, vol. 118, pp. 81-85, 2018.
[48] X. Li, F. Zhang, W. Zhang, X. Shang, J. Han, and P. Liu, "A new method to precisely control the depth of percutaneous screws into the pedicle by counting the rotation number of the screw with low radiation exposure," European Spine Journal, vol. 26, no. 3, pp. 750-753, 2017.
[49] J. L. Stambough, F. El Khatib, A. M. Genaidy, and R. L. Huston, "Strength and fatigue resistance of thoracolumbar spine implants: an experimental study of selected clinical devices," Journal of spinal disorders, vol. 12, no. 5, pp. 410-414, 1999.
[50] D.-Y. Cho, W.-Y. Lee, and P.-C. Sheu, "Treatment of thoracolumbar burst fractures with polymethyl methacrylate vertebroplasty and short-segment pedicle screw fixation," Neurosurgery, vol. 53, no. 6, pp. 1354-1361, 2003.
[51] K. E. Ponnusamy, S. Iyer, G. Gupta, and A. J. Khanna, "Instrumentation of the osteoporotic spine: biomechanical and clinical considerations," The Spine Journal, vol. 11, no. 1, pp. 54-63, 2011.
[52] J. S. Vanichkachorn, A. R. Vaccaro, M. J. Cohen, and J. M. Cotler, "Potential large vessel injury during thoracolumbar pedicle screw removal: a case report," Spine, vol. 22, no. 1, pp. 110-113, 1997.
[53] R. M. Randall, M. Silverstein, and R. Goodwin, "Review of pediatric spondylolysis and spondylolisthesis," Sports medicine and arthroscopy review, vol. 24, no. 4, pp. 184-187, 2016.
[54] D. K. Resnick et al., "Guidelines for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 9: fusion in patients with stenosis and spondylolisthesis," Journal of Neurosurgery: Spine, vol. 2, no. 6, pp. 679-685, 2005.
[55] G. M. Malham, B. Goss, and C. Blecher, "Percutaneous pedicle screw accuracy with dynamic electromyography: the early experience of a traditionally open spine surgeon," Journal of Neurological Surgery Part A: Central European Neurosurgery, vol. 76, no. 04, pp. 303-308, 2015.
[56] J. A. Soriano-Sánchez et al., "Fluoroscopy-guided pedicle screw accuracy with a mini-open approach: a tomographic evaluation of 470 screws in 125 patients," International journal of spine surgery, vol. 9, 2015.
[57] N. I. o. Health, "NIH consensus development panel on osteoporosis prevention, diagnosis, and therapy, March 7-29, 2000: highlights of the conference," South Med J, vol. 94, no. 6, pp. 569-573, 2001.
[58] T. Gangwar, J. Calder, T. Takahashi, J. E. Bechtold, and D. Schillinger, "Robust variational segmentation of 3D bone CT data with thin cartilage interfaces," Medical image analysis, vol. 47, pp. 95-110, 2018.
[59] T. J. Janik, D. D. Harrison, R. Cailliet, S. J. Troyanovich, and D. E. Harrison, "Can the sagittal lumbar curvature be closely approximated by an ellipse?," Journal of orthopaedic research, vol. 16, no. 6, pp. 766-770, 1998.
[60] T. F. Chan and L. A. Vese, "Active contours without edges," IEEE Transactions on image processing, vol. 10, no. 2, pp. 266-277, 2001.
[61] T.-H. Kuo, J. Fang, and R. Lin, "Development of guiding templates for pedicle screw insertion in spine surgery," in The 8th Combined Congress of the Spine and Pediatric Sections, Asia Pacific Orthopaedic Association. Gifu, Japan, 2011.
[62] S.-S. Wu, W. T. Edwards, and H. A. Yuan, "Stiffness between different directions of transpedicular screws and vertebra," Clinical Biomechanics, vol. 13, no. 1, pp. S1-S8, 1998.
[63] K. Matsukawa and Y. Yato, "Lumbar pedicle screw fixation with cortical bone trajectory: A review from anatomical and biomechanical standpoints," Spine surgery and related research, vol. 1, no. 4, pp. 164-173, 2017.
[64] S. J. Troyanovich, R. Cailliet, T. J. Janik, D. D. Harrison, and D. E. Harrison, "Radiographic mensuration characteristics of the sagittal lumbar spine from a normal population with a method to synthesize prior studies of lordosis," Journal of spinal disorders, vol. 10, no. 5, pp. 380-386, 1997.
[65] C. Barrey and A. Darnis, "Current strategies for the restoration of adequate lordosis during lumbar fusion," World journal of orthopedics, vol. 6, no. 1, p. 117, 2015.
[66] D. E. Harrison, D. D. Harrison, R. Cailliet, T. J. Janik, and B. Holland, "Radiographic analysis of lumbar lordosis: centroid, Cobb, TRALL, and Harrison posterior tangent methods," Spine, vol. 26, no. 11, pp. e235-e242, 2001.
[67] J. Lazennec et al., "Sagittal alignment in lumbosacral fusion: relations between radiological parameters and pain," European Spine Journal, vol. 9, no. 1, pp. 47-55, 2000.
[68] Y. Liang et al., "Clinical outcomes and sagittal alignment of single-level unilateral instrumented transforaminal lumbar interbody fusion with a 4 to 5-year follow-up," European Spine Journal, vol. 24, no. 11, pp. 2560-2566, 2015.
[69] F. J. Schwab, V. A. Smith, M. Biserni, L. Gamez, J.-P. C. Farcy, and M. Pagala, "Adult scoliosis: a quantitative radiographic and clinical analysis," Spine, vol. 27, no. 4, pp. 387-392, 2002.
[70] M. Alimi et al., "Expandable polyaryl-ether-ether-ketone spacers for interbody distraction in the lumbar spine," Global spine journal, vol. 5, no. 3, pp. 169-178, 2015.
[71] A. H. Hawasli, J. M. Khalifeh, A. Chatrath, C. K. Yarbrough, and W. Z. Ray, "Minimally invasive transforaminal lumbar interbody fusion with expandable versus static interbody devices: radiographic assessment of sagittal segmental and pelvic parameters," Neurosurgical focus, vol. 43, no. 2, p. E10, 2017.
[72] C. Struwe et al., "A novel PLIF PEEK interbody cage with an impactionless insertion technology: A case series with a mid-term follow up of three years," Technology and Health Care, vol. 25, no. 5, pp. 949-957, 2017.
[73] E. Chong, M. H. Pelletier, R. J. Mobbs, and W. R. Walsh, "The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review," BMC musculoskeletal disorders, vol. 16, no. 1, pp. 1-11, 2015.
[74] S. Najeeb, Z. Khurshid, J. P. Matinlinna, F. Siddiqui, M. Z. Nassani, and K. Baroudi, "Nanomodified peek dental implants: Bioactive composites and surface modification—A review," International journal of dentistry, vol. 2015, 2015.
[75] P. J. Rao, M. H. Pelletier, W. R. Walsh, and R. J. Mobbs, "Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration," Orthopaedic surgery, vol. 6, no. 2, pp. 81-89, 2014.
[76] Y. Chen et al., "Comparison of titanium and polyetheretherketone (PEEK) cages in the surgical treatment of multilevel cervical spondylotic myelopathy: a prospective, randomized, control study with over 7-year follow-up," European Spine Journal, vol. 22, no. 7, pp. 1539-1546, 2013.
[77] Y.-C. Chou et al., "Efficacy of anterior cervical fusion: comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts," Journal of Clinical Neuroscience, vol. 15, no. 11, pp. 1240-1245, 2008.
[78] C.-C. Niu, J.-C. Liao, W.-J. Chen, and L.-H. Chen, "Outcomes of interbody fusion cages used in 1 and 2-levels anterior cervical discectomy and fusion: titanium cages versus polyetheretherketone (PEEK) cages," Clinical Spine Surgery, vol. 23, no. 5, pp. 310-316, 2010.
[79] I. O. Karikari et al., "Impact of subsidence on clinical outcomes and radiographic fusion rates in anterior cervical discectomy and fusion: a systematic review," Clinical Spine Surgery, vol. 27, no. 1, pp. 1-10, 2014.
[80] I. Noordhoek, M. T. Koning, W. C. Jacobs, and C. L. Vleggeert-Lankamp, "Incidence and clinical relevance of cage subsidence in anterior cervical discectomy and fusion: a systematic review," Acta neurochirurgica, vol. 160, no. 4, pp. 873-880, 2018.
[81] M. Kashii, K. Kitaguchi, T. Makino, and T. Kaito, "Comparison in the same intervertebral space between titanium-coated and uncoated PEEK cages in lumbar interbody fusion surgery," Journal of Orthopaedic Science, vol. 25, no. 4, pp. 565-570, 2020.
[82] S. M. Kurtz and J. N. Devine, "PEEK biomaterials in trauma, orthopedic, and spinal implants," Biomaterials, vol. 28, no. 32, pp. 4845-4869, 2007.
[83] J. J. Schimmel, M. S. Poeschmann, P. P. Horsting, D. H. Schönfeld, J. van Limbeek, and P. W. Pavlov, "PEEK cages in lumbar fusion: mid-term clinical outcome and radiologic fusion," Clinical spine surgery, vol. 29, no. 5, pp. E252-E258, 2016.
[84] E. Behrbalk, O. Uri, R. M. Parks, R. Musson, R. C. C. Soh, and B. M. Boszczyk, "Fusion and subsidence rate of stand alone anterior lumbar interbody fusion using PEEK cage with recombinant human bone morphogenetic protein-2," European Spine Journal, vol. 22, no. 12, pp. 2869-2875, 2013.
[85] M.-C. Kim, H.-T. Chung, J.-L. Cho, D.-J. Kim, and N.-S. Chung, "Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion," Clinical Spine Surgery, vol. 26, no. 2, pp. 87-92, 2013.
[86] T. V. Le et al., "Subsidence of polyetheretherketone intervertebral cages in minimally invasive lateral retroperitoneal transpsoas lumbar interbody fusion," Spine, vol. 37, no. 14, pp. 1268-1273, 2012.
[87] J. Gallo, M. Holinka, and C. S. Moucha, "Antibacterial surface treatment for orthopaedic implants," International journal of molecular sciences, vol. 15, no. 8, pp. 13849-13880, 2014.
[88] H. Kakinuma et al., "Antibacterial polyetheretherketone implants immobilized with silver ions based on chelate‐bonding ability of inositol phosphate: processing, material characterization, cytotoxicity, and antibacterial properties," Journal of Biomedical Materials Research Part A, vol. 103, no. 1, pp. 57-64, 2015.
[89] L. De Bartolo, S. Morelli, A. Bader, and E. Drioli, "The influence of polymeric membrane surface free energy on cell metabolic functions," Journal of Materials Science: Materials in Medicine, vol. 12, no. 10, pp. 959-963, 2001.
[90] O. Noiset, Y.-J. Schneider, and J. Marchand-Brynaert, "Fibronectin adsorption or/and covalent grafting on chemically modified PEEK film surfaces," Journal of Biomaterials Science, Polymer Edition, vol. 10, no. 6, pp. 657-677, 1999.
[91] O. Nemoto, T. Asazuma, Y. Yato, H. Imabayashi, H. Yasuoka, and A. Fujikawa, "Comparison of fusion rates following transforaminal lumbar interbody fusion using polyetheretherketone cages or titanium cages with transpedicular instrumentation," European Spine Journal, vol. 23, no. 10, pp. 2150-2155, 2014.
[92] S. Seaman, P. Kerezoudis, M. Bydon, J. C. Torner, and P. W. Hitchon, "Titanium vs. polyetheretherketone (PEEK) interbody fusion: meta-analysis and review of the literature," Journal of Clinical Neuroscience, vol. 44, pp. 23-29, 2017.
[93] F. Cuzzocrea et al., "PEEK versus metal cages in posterior lumbar interbody fusion: a clinical and radiological comparative study," Musculoskeletal surgery, vol. 103, no. 3, pp. 237-241, 2019.
[94] R. J. Mobbs, K. Phan, Y. Assem, M. Pelletier, and W. R. Walsh, "Combination Ti/PEEK ALIF cage for anterior lumbar interbody fusion: early clinical and radiological results," Journal of Clinical Neuroscience, vol. 34, pp. 94-99, 2016.
[95] M. Rickert et al., "Transforaminal lumbar interbody fusion using polyetheretherketone oblique cages with and without a titanium coating: a randomised clinical pilot study," The bone & joint journal, vol. 99, no. 10, pp. 1366-1372, 2017.
[96] W. R. Walsh, M. H. Pelletier, C. Christou, J. He, F. Vizesi, and S. D. Boden, "The in vivo response to a novel Ti coating compared with polyether ether ketone: evaluation of the periphery and inner surfaces of an implant," The Spine Journal, vol. 18, no. 7, pp. 1231-1240, 2018.
[97] B. C. Cheng, S. Koduri, C. A. Wing, N. Woolery, D. J. Cook, and R. C. Spiro, "Porous titanium-coated polyetheretherketone implants exhibit an improved bone–implant interface: an in vitro and in vivo biochemical, biomechanical, and histological study," Medical Devices (Auckland, NZ), vol. 11, p. 391, 2018.
[98] P. C. Celestre, J. R. Dimar 2nd, and S. D. Glassman, "Spinopelvic parameters: lumbar lordosis, pelvic incidence, pelvic tilt, and sacral slope: what does a spine surgeon need to know to plan a lumbar deformity correction?," Neurosurgery Clinics of North America, vol. 29, no. 3, pp. 323-329, 2018. |