參考文獻 |
[1] R. Pallas-Areny and J. G. Webster, Sensors and Signal Conditioning. New York Wiley, 1991.
[2] J. E. Molyneux and A. Witten, "Impedance tomography: imaging algorithms for geophysical applications," Inverse Problems, vol. 10, pp. 655-667, 1994.
[3] S. Friedel, "Resolution, stability and efficiency of resistivity tomography estimated from a generalized inverse approach," vol. 153, pp. 305-316, 2003.
[4] G. J. Gaskin and J. D. Miller, "Measurement of soil water content using a simplified impedance measuring technique," Journal of Agricultural Engineering Research, vol. 63, pp. 153-159, 1996.
[5] F. Djamdji, A. C. Gorvin, I. L. Freeston, R. C. Tozer, I. C. Mayes, and S. R. Blight, "Electrical impedance tomography applied to semiconductor wafer characterization," Measurement Science and Technology, vol. 7, pp. 391-395, 1996.
[6] H. Scharfetter, R. Casanas, and J. Rosell, "Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations," Biomedical Engineering, IEEE Transactions on, vol. 50, pp. 870-880, 2003.
[7] J. Netz, E. Forner, and S. Haagemann, "Contactless impedance measurement by magnetic induction - a possible method for investigation of brain impedance," Physiological Measurement, vol. 14, pp. 463-471, 1993.
[8] B. Ulker Karbeyaz and N. G. Gencer, "Electrical conductivity imaging via contactless measurements: an experimental study," Medical Imaging, IEEE Transactions on, vol. 22, pp. 627-635, 2003.
[9] S. W. Summers RL, Peacock WF, Ander DS, Coleman TG., "Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography," Academic emergency medicine, vol. 10, pp. 668-80, 2003.
[10] I. Frerichs, "Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities," Physiological Measurement, vol. 21, pp. R1-R21, 2000.
[11] K. R. Segal, B. Gutin, E. Presta, J. Wang, and T. B. Van Itallie, "Estimation of human body composition by electrical impedance methods: a comparative study," Journal of Applied Physiology, vol. 58, pp. 1565-1571, 1985.
[12] R. P. Henderson and J. G. Webster, "An impedance camera for spatially specific measurements of the thorax," Biomedical Engineering, IEEE Transactions on, vol. 25, p. 5, 1978.
[13] C. C. Barber, B. H. Brown, and I. L. Freeston, "Imaging spatial distributions of resistivity using applied potential tomography," Electronics Letters, vol. 19, pp. 933-935, 1983.
[14] B. H. Brown and A. D. Seagar, "The Sheffield data collection system," Clinical Physics and Physiological Measurement, vol. 8, p. 91, 1987.
[15] D. Murphy, P. Burton, R. Coombs, L. Tarassenko, and P. Rolfe, "Impedance imaging in the newborn," Clinical Physics and Physiological Measurement, vol. 8, p. 131, 1987.
[16] A. R. Hampshire, R. H. Smallwood, B. H. Brown, and R. A. Primhak, "Multifrequency and parametric EIT images of neonatal lungs," Physiological Measurement, vol. 16, pp. A175-A189, 1995.
[17] S. C. Murphy and T. A. York, "Electrical impedance tomography with non-stationary electrodes," Measurement Science and Technology, vol. 17, pp. 3042-3052, 2006.
[18] F. Dickin and M. Wang, "Electrical resistance tomography for process applications," Measurement Science and Technology, vol. 7, pp. 247-260, 1996.
[19] N. Reinecke and D. Mewes, "Recent developments and industrial/research applications of capacitance tomography," Measurement Science and Technology, vol. 7, pp. 233-246, 1996.
[20] T. York, "Status of electrical tomography in industrial applications," Journal of Electronic Imaging, vol. 10, pp. 608-619, 2001.
[21] H. Zhiyao, W. Baoliang, and L. Haiqing, "Application of electrical capacitance tomography to the void fraction measurement of two-phase flow," Instrumentation and Measurement, IEEE Transactions on, vol. 52, pp. 7-12, 2003.
[22] B. H. Brown, "Medical impedance tomography and process impedance tomography: a brief review," Measurement Science & Technology, vol. 12, pp. 991-996, Aug 2001.
[23] W. D. Hou and Y. L. Mo, "Increasing image resolution in electrical impedance tomography," Electronics Letters, vol. 38, pp. 701-702, 2002.
[24] P. A. T. Pinheiro, W. W. Loh, and F. J. Dickin, "Optimal sized electrodes for electrical resistance tomography," Electronics Letters, vol. 34, pp. 69-70, 1998.
[25] P. Hua, E. J. Woo, J. G. Webster, and W. J. Tompkins, "Using compound electrodes in electrical impedance tomography," Biomedical Engineering, IEEE Transactions on, vol. 40, pp. 29-34, 1993.
[26] M. X. Tang, W. Wang, J. Wheeler, M. McCormick, and X. Z. Dong, "The number of electrodes and basis functions in EIT image reconstruction," Physiological Measurement, vol. 23, pp. 129-140, Feb 2002.
[27] N. Polydorides and H. McCann, "Electrode configurations for improved spatial resolution in electrical impedance tomography," Measurement Science and Technology, vol. 13, pp. 1862-1870, 2002.
[28] J. Frounchi and A. Bazzazi, "High resolution rotary capacitance tomography system," in Proc. 3rd World Congress on IPT, Banff, Canada, 2003, pp. 858–863.
[29] J. G. Webster, "Encyclopedia of Medical Devices and Instrumentation," 2nd ed: Wiley, 2006.
[30] D. S. Holder, "Electrical Impedance Tomography : Methods, History, and Applications," Bristol ; Philadelphia: Institute of Physics, 2005.
[31] P. C. Hansen, "Rank-deficient and Discrete Ill-posed Problems /Numerical Aspects of Linear Inversion," Philadelphia: Society for Industrial and Applied Mathematics, 1998.
[32] P. Metherall, "Three dimensional electrical impedance tomography of the human thorax," in Medical Physics and Clinical Engineering: University of Sheffield, 1998.z
[33] E. Somersalo, M. Cheney, and D. Isaacson, "Existence and uniqueness for electrode models for electric current computed tomography," SIAM Journal on Applied Mathematics, vol. 52, pp. 1023-1040, 1992.
[34] A. Adler and R. Guardo, "Electrical impedance tomography: regularized imaging and contrast detection," Medical Imaging, IEEE Transactions on, vol. 15, pp. 170-179, 1996.
[35] B. M. Eyuboglu, T. C. Pilkington, and P. D. Wolf, "Estimation of tissue resistivities from multiple-electrode impedance measurements," Phys. Med. Biol., vol. 39, p. 1, 1994.
[36] D. B. Geselowitz, "An application of electrocardiographic lead theory to impedance plethysmography," Biomedical Engineering, IEEE Transactions on, vol. BME-18, pp. 38-41, 1971.
[37] J. C. De Munck, T. J. C. Faes, A. J. Hermans, and R. M. Heethaar, "A Parametric Method to Resolve the Ill-Posed Nature of the EIT Reconstruction Problem: A Simulation Study," Annals of the New York Academy of Sciences, vol. 873, pp. 440-453, 1999.
[38] T. J. Yorkey, J. G. Webster, and W. J. Tompkins, "Comparing reconstruction algorithms for electrical impedance tomography," Biomedical Engineering, IEEE Transactions on, vol. BME-34, pp. 843-852, 1987.
[39] M. Cheney, D. Isaacson, and J. C. Newell, "Electrical impedance tomography." vol. 41: Society for Industrial and Applied Mathematics, 1999, pp. 85-101.
[40] J. Agnieszka and W. Jerzy, "An EIT reconstruction algorithm: comparison of one-step and iterative versions," vol. 5505, pp. 144-150, 2004.
[41] W. R. B. Lionheart, "EIT reconstruction algorithms: pitfalls, challenges and recent developments," Physiological Measurement, vol. 25, pp. 125-142, 2004.
[42] M. Cheney, D. Isaacson, J. C. Newell, S. Simske, and J. Goble, "NOSER: An Algorithm for Solving the Inverse Conductivity Problem," International Journal of Imaging Systems & Technology, vol. 2, pp. 66-75, Summer 1990.
[43] B. Lionheart and A. Adler., "Electrical impedance and diffuse optical tomography reconstruction software " http://eidors3d.sourceforge.net/.
[44] P. M. Edic, D. Isaacson, G. J. Saulnier, H. Jain, and J. C. Newell, "An iterative Newton-Raphson method to solve the inverse admittivity problem," Biomedical Engineering, IEEE Transactions on, vol. 45, pp. 899-908, 1998.
[45] A. L. Hyaric and M. K. Pidcock, "An image reconstruction algorithm for three-dimensional electrical impedance tomography," Biomedical Engineering, IEEE Transactions on, vol. 48, pp. 230-235, 2001.
[46] A. L. Hyaric and M. K. Pidcock, "A one step image reconstruction algorithm for electrical impedance tomography in three dimensions," Physiol. Meas., vol. 21, p. 95, 2000.
[47] M. Mayer, P. Brunner, R. Merwa, F. M. Smolle-Juttner, A. Maier, and H. Scharfetter, "Direct reconstruction of tissue parameters from differential multifrequency EIT in vivo," Physiological Measurement, vol. 27, pp. S93-S101, May 2006.
[48] M. Soleimani, C. Gomez-Laberge, and A. Adler, "Imaging of conductivity changes and electrode movement in EIT," Physiological Measurement, vol. 27, pp. S103-S113, May 2006.
[49] W. Huaxiang, W. Chao, and Y. Wuliang, "A pre-iteration method for the inverse problem in electrical impedance tomography," Instrumentation and Measurement, IEEE Transactions on, vol. 53, pp. 1093-1096, 2004.
[50] C. J. Grootveld, A. Segal, and B. Scarlett, "Regularized modified Newton-Raphson technique applied to electrical impedance tomography," International Journal of Imaging Systems and Technology, vol. 9, pp. 60-65, 1998.
[51] P. Hua, E. J. Woo, J. G. Webster, and W. J. Tompkins, "Iterative reconstruction methods using regularization and optimal current patterns in electrical-impedance tomography," Medical Imaging, IEEE Transactions on, vol. 10, pp. 621-628, 1991.
[52] M. Vauhkonen, D. Vadasz, P. A. Karjalainen, E. Somersalo, and J. P. Kaipio, "Tikhonov regularization and prior information in electrical impedance tomography," Medical Imaging, IEEE Transactions on, vol. 17, pp. 285-293, 1998.
[53] T. Murai and Y. Kagawa, "Electrical impedance computed tomography based on a finite element model," Biomedical Engineering, IEEE Transactions on, vol. BME-32, pp. 177-184, 1985.
[54] Y. Bard, "Comparison of gradient methods for the solution of nonlinear parameter estimation problems," SIAM Journal on Numerical Analysis, vol. 7, pp. 157-186, 1970.
[55] P. Hua, J. G. Webster, and W. J. Tompkins, "A regularised electrical impedance tomography reconstruction algorithm," Clinical Physics and Physiological Measurement, vol. 9, p. 137, 1988.
[56] H. Akaike, "A new look at the statistical model identification," Automatic Control, IEEE Transactions on, vol. 19, pp. 716-723, 1974.
[57] P. C. Hansen, "Analysis of discrete ill-posed problems by means of the L-curve," SIAM Review, vol. 34, pp. 561-580, 1992.
[58] B. M. Graham and A. Adler, "Objective selection of hyperparameter for EIT," Physiological Measurement, vol. 27, pp. S65-S79, May 2006.
[59] M. Vauhkonen, W. R. B. Lionheart, L. M. Heikkinen, P. J. Vauhkonen, and J. P. Kaipio, "A MATLAB package for the EIDORS project to reconstruct two-dimensional EIT images," Physiological Measurement, vol. 22, pp. 107-111, 2001.
[60] N. Polydorides and W. R. B. Lionheart, "A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software project," Measurement Science and Technology, vol. 13, pp. 1871-1883, 2002.
[61] A. Adler and W. R. B. Lionheart, "Uses and abuses of EIDORS: an extensible software base for EIT," Physiol. Meas., vol. 27, p. S25, 2006.
[62] M. Shini and B. Rubinsky, "Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography," Physiological Measurement, vol. 29, pp. 109-126, 2008.
[63] D. R. Stephenson, M. Cooke, A. Kowalski, and T. A. York, "Determining jet mixing characteristics using electrical resistance tomography," Flow Measurement and Instrumentation, vol. 18, pp. 204-210, 2007.
[64] A. Tizzard and R. H. Bayford, "Improving the finite element forward model of the human head by warping using elastic deformation," Physiological Measurement, vol. 28, pp. S163-S182, 2007.
[65] R. Wajman, R. Banasiak, L. Mazurkiewicz, T. Dyakowski, and D. Sankowski, "Spatial imaging with 3D capacitance measurements," Measurement Science & Technology, vol. 17, pp. 2113-2118, Aug 2006.
[66] T. Zhao, M. Takei, K. Masaki, R. Ogiso, K. Nakao, and A. Uchiura, "Sensor design and image accuracy for application of capacitance CT to the petroleum refinery process," Flow Measurement and Instrumentation, vol. 18, pp. 268-276, Oct-Dec 2007.
[67] T. A. York, J. L. Davidson, L. Mazurkiewich, R. Mann, and B. D. Grieve, "Towards process tomography for monitoring pressure filtration," IEEE Sensors Journal, vol. 5, pp. 139-152, 2005.
[68] J. G. Webster, "Medical Instrumenttation," Wiley, 1997, p. 189.
[69] L. W. Hart, H. W. Ko, J. H. Meyer, Jr., D. P. Vasholz, and R. I. Joseph, "A noninvasive electromagnetic conductivity sensor for biomedical applications," Biomedical Engineering, IEEE Transactions on, vol. 35, pp. 1011-1022, 1988.
[70] C. W. L. Denyer, "Electronics for real-time and three-dimensional electrical impedance tomographs ". vol. Ph.D.: Oxford Brookes University, 1996.
[71] K. G. Boone and D. S. Holder, "Current approaches to analogue instrumentation design in electrical impedance tomography," Physiological Measurement, vol. 17, pp. 229-247, 1996.
[72] A. S. Ross, G. J. Saulnier, J. C. Newell, and D. Isaacson, "Current source design for electrical impedance tomography," Physiological Measurement, vol. 24, pp. 509-516, May 2003.
[73] D. Brooks, "Crosstalk coupling: single-ended vs. differential," UltraCAD Design, Inc. , 2005.
[74] M. Min, O. Martens, and T. Parve, "Lock-in measurement of bio-impedance variations," Measurement, vol. 27, pp. 21-28, 2000.
[75] D. G. Gisser, D. Isaacson, and J. C. Newell, "Electric current computed tomography and eigenvalues," SIAM Journal on Applied Mathematics, vol. 50, pp. 1623-1634, 1990.
[76] M. Molinari, S. J. Cox, B. H. Blott, and G. J. Daniell, "Adaptive mesh refinement techniques for electrical impedance tomography," Physiological Measurement, vol. 22, pp. 91-96, 2001.
[77] M. Zadehkoochak, B. H. Blott, T. K. Hames, and R. F. George, "Spectral expansion analysis in electrical impedance tomography," Journal of Physics D: Applied Physics, vol. 24, pp. 1911-1916, 1991.
[78] M. Tang, W. Wang, J. Wheeler, M. McCormick, and X. Dong, "The number of electrodes and basis functions in EIT image reconstruction," Physiological Measurement, vol. 23, pp. 129-140, 2002.
[79] S. Meeson, A. L. T. Killingback, and B. H. Blott, "The dependence of EIT images on the assumed initial conductivity distribution: a study of pelvic imaging," Physics in Medicine and Biology, vol. 40, pp. 643-657, 1995.
[80] M. Soleimani, "Image and shape reconstruction methods in magnetic induction and electrical impedance tomography," in Engineering and Physical Sciences. vol. Ph.D.: Manchester, 2005.
[81] W. Wang, B. H. Brown, A. D. Leathard, and L. Lu, "Noise equalization within EIT images," Physiological Measurement, vol. 15, pp. A211-A216, 1994.
[82] A. M. Sinton, B. H. Brown, D. C. Barber, F. J. McArdle, and A. D. Leathard, "Noise and spatial resolution of a real-time electrical impedance tomograph," Clinical Physics and Physiological Measurement, vol. 13, pp. 125-130, 1992.
[83] A. R. Frangi, P. J. Riu, J. Rosell, and M. A. Viergever, "Propagation of measurement noise through backprojection reconstruction in electrical impedance tomography," Medical Imaging, IEEE Transactions on, vol. 21, pp. 566-578, 2002.
[84] P. Record, M. Wang, and F. Dickin, "Conducting boundary strategy: a new technique for medical EIT," Physiological Measurement, vol. 16, pp. A249-A255, 1995.
[85] J. L. Davidson, L. S. Ruffino, D. R. Stephenson, R. Mann, B. D. Grieve, and T. A. York, "Three-dimensional electrical impedance tomography applied to a metal-walled filtration test platform," Measurement Science and Technology, vol. 15, pp. 2263-2274, 2004.
[86] M. Wang, F. J. Dickin, and R. A. Williams, "Electrical resistance tomography of metal walled vessels and pipelines," Electronics Letters, vol. 30, pp. 771-773, 1994.
[87] W. Huaxiang, W. Chao, and Y. Wuliang, "Optimum design of the structure of the electrode for a medical EIT system," Measurement Science and Technology, vol. 12, pp. 1020-1023, 2001.
[88] H. Griffiths, "Magnetic induction tomography," Measurement Science and Technology, vol. 12, pp. 1126-1131, 2001.
[89] H. Scharfetter, R. Merwa, and K. Pilz, "A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT)," Physiological Measurement, vol. 26, pp. S307-S318, 2005.
[90] R. W. M. Smith, I. L. Freeston, and B. H. Brown, "A real-time electrical impedance tomography system for clinical use-design and preliminary results," Biomedical Engineering, IEEE Transactions on, vol. 42, pp. 133-140, 1995.
[91] J. C. Newell, P. M. Edic, R. Xiaodan, J. L. Larson-Wiseman, and M. D. Danyleiko, "Assessment of acute pulmonary edema in dogs by electrical impedance imaging," Biomedical Engineering, IEEE Transactions on, vol. 43, pp. 133-138, 1996.
[92] H. S. Tapp, A. J. Peyton, E. K. Kemsley, and R. H. Wilson, "Chemical engineering applications of electrical process tomography," Sensors and Actuators B: Chemical, vol. 92, pp. 17-24, 2003.
[93] M. Schiebe, Real-time Systems: Engineering and Applications: Boston Kluwer Academic Publishers 1992.
[94] J. Fritschy, L. Horesh, D. S. Holder, and R. H. Bayford, "Using the GRID to improve the computation speed of electrical impedance tomography (EIT) reconstruction algorithms," Physiological Measurement, vol. 26, pp. S209-S215, 2005.
[95] P. M. Edic, G. J. Saulnier, J. C. Newell, and D. Isaacson, "A real-time electrical impedance tomograph," Biomedical Engineering, IEEE Transactions on, vol. 42, pp. 849-859, 1995.
[96] G. Y. Dong, R. H. Bayford, S. K. Gao, Y. Saito, R. Yerworth, D. Holder, and W. L. Yan, "The application of the generalized vector sample pattern matching method for EIT image reconstruction," Physiological Measurement, vol. 24, pp. 449-466, May 2003.
[97] G. Y. Dong, H. S. Liu, R. H. Bayford, R. Yerworth, P. H. Schimpf, and W. L. Yan, "Spatial resolution improvement of 3D EIT images by the shrinking sLORETA-FOCUSS algorithm," Physiological Measurement, vol. 26, pp. S199-S208, 2005.
[98] W.-S. Lai, "The design of contour-tracing electrode-array for electrical impedance tomography applications," in Institute of Biomedical Engineering. vol. Master's Thesis: National Cheng Kung University, 2001.
[99] P. Metherall, D. C. Barber, R. H. Smallwood, and B. H. Brown, "Three-dimensional electrical impedance tomography," Nature, vol. 380, pp. 509-512, Apr 1996.
[100] J. Lehr, "A vector derivation useful in impedance plethysmographic field calculations," Biomedical Engineering, IEEE Transactions on, vol. BME-19, pp. 156-157, 1972. |