從歷年來的地震經驗中可以察覺,當管線與設備的破壞喪失其自身功能時,會造成重要建築物無法繼續運作,其所產生的損害之影響是不可忽視的,而台灣地處環太平洋地震帶上,在地震頻繁的環境下,管線與設備的耐震能力之評估值得我們重視。 本論文為針對管線與設備提供一套快速、完整與有效的評估程序。管線檢核表為參考美國消防協會(NFPA)與工廠互助保險實驗室(FM)所出版的規範加以整理,設備檢核表是將美國多學科地震工程研究所中心(MCEER)所發行的設備檢核表加以修改,使其能適用於台灣之應用。 We may learn from the past earthquake experience that when pipes and equipment are to be damaged to lose their function, the major buildings would not continue to properly function and the detriment it results should not be overlooked. Located on the Pacific seismic belt, Taiwan is under an environment where earthquakes are frequent. Under such circumstances, the evaluation for the quake resistance of pipes and equipment are worth paying attention to. Aiming at pipes and equipment, this paper has submitted a set of rapid, intact and effective evaluation procedure. The pipe check list has been made by making reference to the norms published by the National Fire Protection Association (NFPA) in the U.S. and Factory Mutual Insurance Company (FM). The equipment check list has been modified from the equipment check list published by Multidisciplinary Center for Earthquake Engineering Research (MCEER) to make it fit for Taiwan.