中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/1653
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78852/78852 (100%)
造访人次 : 37841181      在线人数 : 527
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/1653


    题名: 導電平板之定頻掃描方法研究;The Research of Scanning on a Conducting Plate using Constant Frequency
    作者: 吳昇翰;Sheng-Han Wu
    贡献者: 光機電工程研究所
    关键词: 溶液電阻;電雙層電容;極化電阻;頻率響應;電極間距;微陽極電鍍;micro anode guided electroplating;electrodes distance;frequency response;polarization resistance;solution resistance;double-layer capacitance
    日期: 2007-07-02
    上传时间: 2009-09-21 09:57:07 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 為了取得電極間的距離進而控制電鍍的程序因此進行了電鍍時的溶液電阻量測研究,我們發現使用頻率為90kHz或是更高頻率之交流測試訊號可以使得電雙層電容與極化電阻相對於存在於電極間之溶液電阻而言變得可以忽略。因此,溶液阻抗的量測變得可行。 當包覆在粗的塑脂絕緣鞘中的細電極在近距離面對導電平板,因為狹窄通道效應會限制了有效的導通區域為電極下的截面積,因此有效的溶液電阻與間距會呈現一負相關。對125uM直徑的電極而言,間距在150μm以下都會有通道效應。藉此關係可以進行精密的導體表面輪廓掃描。 當電極與平板陰極的距離大於150uM以上,或者當析出之針狀物高度大於這個值以後,容液電阻值與電極間距的關係不再明顯,而不像導線中帶電粒子有集中式的通道而呈現與長度有正比的關係。因而無法用溶液電阻值來反映電極間距。 Studying the measurement of solution resistance in electro-plating so as to derive the information on the distance between electrodes for the control of the electro-plating process, we found an AC test signal of frequency 90KHz or higher renders the impedence of the double layer capacitance and the polarization resistance negligible to the solution resistance between the electrodes. Therefore, the measurement of solution impedance becomes possible. When a thin electrode is insulated by a thick epoxy sheath and with the tip face of the electrode brought very close to a flat conducting plate electrode, channel effect would constrain the effective conducting section to the area directly underneath the electrode tip. The effective solution resistance and distance between electrodes exhibit a negative correlation. As the gap distance becomes larger, the conducting cross section becomes wider and the solution resistance becomes smaller. For an electrode of 125uM, the channel effect is apparent in gap shorter than 150uM. Precision surface shape scanning was developed applying this discovery. When the distance between the electrode and the plate electrode becomes bigger than 150uM, or when the height of the deposit grows longer than this value, the solution resistance becomes irrelevant to the distance between the electrodes. The channel for catalytic ions is distributed throughout the space around the electrodes, unlike the conducting wire constraining the conduction evenly in the cross section of the conductor. Therefore, it is ineffective to derive gap distance from the solution resistance.
    显示于类别:[光機電工程研究所 ] 博碩士論文

    文件中的档案:

    档案 大小格式浏览次数


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明