中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/2158
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 78937/78937 (100%)
Visitors : 39421852      Online Users : 628
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/2158


    Title: 噴霧熱傳增強冷凝器及空調機性能測試分析;Heat transfer enhanced of moisture sprayed condenser and testing analysis of air-conditioner performance.
    Authors: 胡毓堂;Yu-Tang Fu
    Contributors: 機械工程研究所
    Keywords: 噴霧;熱傳增強;冷凝器;spray;heat transfer enhancement;condenser
    Date: 2002-07-17
    Issue Date: 2009-09-21 11:39:42 (UTC+8)
    Publisher: 國立中央大學圖書館
    Abstract: 本研究以扁平管平行流冷凝器加上一噴霧裝置,用以達到熱傳增強的效果,並以開放式風洞測試冷凝器在不同噴霧量、風量及相對濕度下之鰭側性能。並將噴霧式冷凝器應用於一市售之窗型空調機上,比較空調機未噴霧、噴霧及葉片打水的能源效率比(EER)。 由測試結果得知,不管是噴霧或葉片打水都可增加系統冷凍能力使EER值提升,但只有以噴霧方式才能解決葉片打水所產生的噪音問題。 Condenser and evaporator have the largest volume and highest potential for performance improvement. The test result shows that the moisture spray enhanced condenser may effectively improve the overall air-conditioner performance. The purpose of this paper is to develop a newly designed high performance air-conditioner with a moisture sprayed condenser.
    Appears in Collections:[Graduate Institute of Mechanical Engineering] Electronic Thesis & Dissertation

    Files in This Item:

    File SizeFormat


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明