    Title: 文氏管式噴霧熱傳增強冷凝器測試分析;Heat transfer enhanced of Venturi tube type moisture sprayed condenser testing and analysis
    Authors: 黃恩新;En-Xin Huang
    Contributors: 機械工程研究所
    Keywords: 噴霧;熱傳增強;heat transfer enhancement;spray
    Date: 2003-07-16
    Issue Date: 2009-09-21 11:42:35 (UTC+8)
    Publisher: 國立中央大學圖書館
    Abstract: 摘 要 本實驗以噴霧的方式來增強扁平管平行流冷凝器的熱傳性能。於一開放式風洞中進行冷凝器在不同噴霧量、風量及相對濕度下,其熱傳與壓降性能的變化。噴霧的方式為利用伯努力定律,配合文氏管噴霧器將水分噴於入口空氣中,因水份蒸發帶走熱量,來降低空氣入口溫度,達到熱傳增強的效果。 實驗結果發現,噴霧方式確實能提升熱傳性能,但應注意噴霧量不可超出空氣的飽合量,否則多餘的水分將會積於鰭片之間,造成壓降增加,熱傳效果也得不到提升。 Experiments were conducted in this research to investigate the influence of enhancing the heat transfer performance of condencer by condensing water. Different spray rate,flow velocity and relative humidity was tested in an open style wind tunnel to understand the chang of heat transfer and pressure drop performance.
    Appears in Collections:[Graduate Institute of Mechanical Engineering] Electronic Thesis & Dissertation

    Files in This Item:

    File SizeFormat


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明