中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/2490
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 41643650      在线人数 : 1197
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/2490


    题名: 以液晶熱像法探討微小管內之熱傳特性;Experimental Analysis on Forced Convective Heat Transfer Characteristics in Micro Tubes by the Method of Liquid Crystal Thermography
    作者: 林廷祐;Ting-Yu Lin
    贡献者: 機械工程研究所
    关键词: 熱分流;液晶熱像法;熱對流熱傳係數;微小管;micro tubes;convective heat transfer;thermal shunt;liquid crystal thermography
    日期: 2007-07-20
    上传时间: 2009-09-21 11:48:21 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 本研究利用液晶熱像法來量測微小管溫度以求得水流經微小管的對流熱傳係數,這個方法可以有效的避免用熱偶計等接觸式溫度量測方法所產生的熱分流問題,本研究中微小管的管徑大小分佈從123到962微米,實驗結果顯示完全發展流的摩擦係數及熱傳係數與傳統理論十分吻合。不同管徑下轉換流皆發生在雷諾數從2,300到3,000,與傳統大管徑下轉換流發生的雷諾數一樣。隨著管徑越小層流的熱完全發展長度有較傳統預測式更長的趨勢,在熱發展區管徑962微米所測得的紐賽數與Shah and Bhatti [1987]預測結果十分吻合。在本研究中液晶熱像法的準確度可以高達0.4 oC,這個方法可以更進一步應用到管徑更微小,熱分流更嚴重微小管的溫度量測。 This study proposes a non-contacted Liquid Crystal Thermography (LCT) method for micro tube surface temperature measurement. It avoids the thermal shunt error caused while using the direct contact thermocouples. Forced convective heat transfer performance of water flowing through six micro tubes with inner diameters ranging from 123 to 962 μm were tested. The test results show that the conventional heat transfer and flow resistance correlations for laminar and turbulent flow can well be applied for predicting the fully developed heat transfer performance and friction factor in micro tubes. The transition occurs at Reynolds number from 2,300 to 3,000. This is also the same range as that for conventional larger tubes. The laminar thermal entrance length for micro tubes is longer than that estimated by the conventional correlation. The developing Nusselt numbers for 962 μm tube agrees well with those correlations predicted by the Shah and Bhatti [1987]. The uncertainty applied to measure the micro tube surface temperature is lower than 0.4 oC. It can be further applied for measuring smaller tube surface temperature that the thermal shunt may be more significant by using direct contact temperature measurements methods.
    显示于类别:[機械工程研究所] 博碩士論文

    文件中的档案:

    档案 大小格式浏览次数


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明