中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/26596
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41777235      線上人數 : 1999
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/26596


    題名: Does the catheter-tip position in cardiac catheterization affect assessment of aortic valve stenosis? An in vitro study
    作者: Sung,HW;Yu,PS
    貢獻者: 化學工程與材料工程學系
    關鍵詞: PULMONARY-ARTERY MODEL;FLOW VELOCITY PATTERNS;PRESSURE RECOVERY;PULSATILE INVITRO;STEADY
    日期: 1996
    上傳時間: 2010-06-29 17:31:58 (UTC+8)
    出版者: 中央大學
    摘要: Aortic stenosis is a common valvular disease. In clinical practice, cardiac catheterization is often used to assess the severity of aortic valve stenosis. However, in conducting catheterization, the precise position of the catheter tip is often not known or controlled. From the standpoint of hydrodynamics, the position of the catheter tip may affect pressure measurement due to the complicated flow fields distal to the valve. This fact is particularly true when the diagnosed valve is stenotic. The objective of this study, using an in vitro model, was to investigate the flow fields in the vicinity of varying degrees of aortic valve stenosis. Additionally, the effect of the catheter-tip position in cardiac catherization on assessing the severity of aortic valve stenosis was analyzed. In the study, laser flow visualization was used to investigate the flow fields, and a pressure transducer with a side-hole catheter was employed to measure pressures. In the flow visualization study, jet-type flows were observed distal to the stenotic valves. A higher degree of valvular stenosis corresponded to a higher velocity jet. As the flow traveled downstream, the jet-type flow expanded and its velocity decreased. Furthermore, the flow turbulence distal to the valve grew with increasing degree of valvular stenosis. In the catheterization study, some degree of pressure recovery was observed along the axial direction for all the cases studied. The magnitude of pressure recovery increased as the valve became more stenotic. However, there was no significant variation in transvalvular pressure drop measured along the radial direction for all the cases studied (p<0.05). The results of this study show that the pressure recovery along the axial direction distal to a stenotic valve may cause significant underestimation of pressure drop measured by catheterization. However, the position of the catheter-tip along the radial direction in catheterization does not seem to affect pressure drop measurement.
    關聯: JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS
    顯示於類別:[化學工程與材料工程研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML421檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明