中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/26818
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 77786/77787 (100%)
造访人次 : 39765895      在线人数 : 601
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/26818


    题名: EFFECTS OF DISTAL NAIL-HOLE DIMENSION AND WALL THICKNESS ON THE FEMORAL NAILING STRESSES - FINITE-ELEMENT ANALYSIS
    作者: Shih,KS;Tseng,CS;Lee,CC;Lu,TW;Hou,SM;Lin,SC
    贡献者: 生物醫學工程研究所
    关键词: STRAIN DISTRIBUTION;LOCKING SCREWS;INTACT FEMUR;FRACTURES;REMOVAL;SHAFT
    日期: 2009
    上传时间: 2010-06-29 17:54:18 (UTC+8)
    出版者: 中央大學
    摘要: Background. For the available systems, the two paired nail holes at the distal femoral portion were of identical size and shape. However, the higher incidence of the first nail-hole failure was reported at the medial than lateral side. In practice, the nail was initially stabilized by the screw insertion into the first hole from the lateral-to-medial side. If the lateral first hole was adequately strengthened, the larger nail-hole diameter could ease to insert the screws into the lateral hole. Methods. The finite-element method was used to investigate the effect of the configuration of the lateral first hole on the screw insertion and stress distribution of the distal nailing system. The distal nail-hole thickness was increased and its edge was intentionally chamfered to increase its effectively projected area onto the sagittal plane. There were eight variations of the nail-hole configuration in the parametric analyses. Findings. The deflected nail diagonally contacts the screws at the medial first and lateral second nail-screw sites. The medial first hole was the most stressed and the stress of the medial second hole was the least. The increase in the nail-hole thickness significantly reduces the concentrated stresses of all four holes, thus allowing the lateral first nail-hole diameter to be increased without the strength loss at that site. The enlargement and chamfer of the lateral first hole significantly increase the effective nail-hole projected area and potentially facilitate the screw insertion. Comparatively, the size and shape re-design of the lateral first hole induced the minor increase in stress values of the other holes and screws. Interpretation. In nature, the load-transferring mechanism between the distal nail-screw interfaces was the point-contact problem. If the wall-thickness, diameter, and chamfer of the lateral first hole were well-controlled, this re-design decreases the stress at the medial first distal hole where most failures occur and renders the overall system mechanically safer and more surgically effective.
    關聯: BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS
    显示于类别:[生物醫學工程研究所 ] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML882检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明