English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41644683      線上人數 : 1157
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/26841


    題名: Comparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone
    作者: Tsai,WC;Chen,PQ;Lu,TW;Wu,SS;Shih,KS;Lin,SC
    貢獻者: 機械工程研究所
    關鍵詞: FINITE-ELEMENT ANALYSES;INCREASING BENDING STRENGTH;CANCELLOUS BONE;HOLDING POWER;BIOMECHANICAL TESTS;INSERTIONAL TORQUE;OUT STRENGTH;SPINE;FIXATION;LUMBAR
    日期: 2009
    上傳時間: 2010-06-29 18:01:29 (UTC+8)
    出版者: 中央大學
    摘要: Background: This study was designed to derive the theoretical formulae to predict the pullout strength of pedicle screws with an inconstant outer and/or inner diameter distribution ( conical screws). For the transpedicular fixation, one of the failure modes is the screw loosening from the vertebral bone. Hence, various kinds of pedicle screws have been evaluated to measure the pullout strength using synthetic and cadaveric bone as specimens. In the literature, the Chapman's formula has been widely proposed to predict the pullout strength of screws with constant outer and inner diameters (cylindrical screws). Methods: This study formulated the pullout strength of the conical and cylindrical screws as the functions of material, screw, and surgery factors. The predicted pullout strength of each screw was compared to the experimentally measured data. Synthetic bones were used to standardize the material properties of the specimen and provide observation of the loosening mechanism of the bone/screw construct. Results: The predicted data from the new formulae were better correlated with the mean pullout strength of both the cylindrical and conical screws within an average error of 5.0% and R-2 = 0.93. On the other hand, the average error and R-2 value of the literature formula were as high as -32.3% and -0.26, respectively. Conclusion: The pullout strength of the pedicle screws was the functions of bone strength, screw design, and pilot hole. The close correlation between the measured and predicted pullout strength validated the value of the new formulae, so as avoid repeating experimental tests.
    關聯: BMC MUSCULOSKELETAL DISORDERS
    顯示於類別:[機械工程研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML887檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明