English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 78852/78852 (100%)
造訪人次 : 38698871      線上人數 : 4653
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/28282


    題名: Development and Residue Screening of the Furazolidone Metabolite, 3-Amino-2-oxazolidinone (AOZ), in Cultured Fish by an Enzyme-Linked Immunosorbent Assay
    作者: Cheng,CC;Hsieh,KH;Lei,YC;Tai,YT;Chang,TH;Sheu,SY;Li,WR;Kuo,TF
    貢獻者: 中央大學
    關鍵詞: PERFORMANCE LIQUID-CHROMATOGRAPHY;SOLID-PHASE EXTRACTION;MASS-SPECTROMETRY;NITROFURAN FURAZOLIDONE;PORCINE TISSUES;EDIBLE TISSUES;LC-MS/MS;FURALTADONE;ANTIBODIES;MUSCLE
    日期: 2009
    上傳時間: 2010-06-29 19:45:26 (UTC+8)
    出版者: 化學研究所
    摘要: A sensitive and specific polyclonal enzyme-linked immunosorbent assay (ELISA) for the determination of tissue-bound metabolite 3-amino-2-oxazolidinone (AOZ) is described. The procedures allow for the detection of protein-bound AOZ in the form of a 2-nitrophenyl derivative (2-NP-AOZ) in the sample supernatant or extract after acid hydrolysis and derivatization with o-nitrobenzaldehyde. The polyclonal rabbit antibodies were produced with the immunogen hapten, 2-NP-HXA-AOZ, and the 50% inhibition values (IC50) of 0.14 mu g kg(-1) of AOZ was achieved with the most sensitive antibody A0505. The mean lower detection limit of the ELISA method is about 0.025 mu g kg(-1). According to the test preparation record, the detection limit is 0.1 mu g kg(-1), which is well below the minimum required performance limits (MRPLs) for tissue-bound residues of AOZ at 1 mu g kg(-1) in the European Communities. In the present study, we investigated the use of homemade ELISA, a new immunoassay, to monitor the presence of the furazolidone marker residue in 370 samples of cultured fish. Adopting 0.3 mu g kg(-1) AOZ as a cutoff value, the ELISA has a sensitivity of 100% and a specificity of 98.5% versus high-performance liquid chromatography-mass spectrometry (HPLC-MS) at a cutoff of 0.3 mu g kg(-1) and gives no false-negative rate results. From the practical point of view, the homemade kit could be advantageously used for the screening of large groups of animal-edible tissue samples and the kit employed has good reliability even in routine application for the control of the illegal use of the drug.
    關聯: JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY
    顯示於類別:[化學研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML701檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明