    Title: Influence of muscular contractions on the stress analysis of distal femoral interlocking nailing
    Authors: Shih,Kao-Shang;Tseng,Ching-Shiow;Lee,Chia-Ching;Lin,Shang-Chih
    Contributors: 生物醫學工程研究所
    Keywords: INTRAMEDULLARY NAIL;STRAIN DISTRIBUTION;BIOMECHANICAL ANALYSIS;SHAFT FRACTURES;LOCKING SCREWS;MUSCLE FORCES;INTACT FEMUR;FIXATION;GAIT
    Date: 2008
    Issue Date: 2010-07-06 15:52:57 (UTC+8)
    Publisher: 中央大學
    Abstract: Background In the literature, the commonly assumed loading conditions on the proximal femur are hip compression and/or gluteus contractions. However, no study has discussed the influence of muscle forces on failure of distal nail holes and locking screws.
    Relation: CLINICAL BIOMECHANICS????
    Appears in Collections:[Institute of Biomedical Engineering] journal & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML964View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明