中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/29751
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 78818/78818 (100%)
Visitors : 34788296      Online Users : 717
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/29751


    Title: Influence of muscular contractions on the stress analysis of distal femoral interlocking nailing
    Authors: Shih,Kao-Shang;Tseng,Ching-Shiow;Lee,Chia-Ching;Lin,Shang-Chih
    Contributors: 生物醫學工程研究所
    Keywords: INTRAMEDULLARY NAIL;STRAIN DISTRIBUTION;BIOMECHANICAL ANALYSIS;SHAFT FRACTURES;LOCKING SCREWS;MUSCLE FORCES;INTACT FEMUR;FIXATION;GAIT
    Date: 2008
    Issue Date: 2010-07-06 15:52:57 (UTC+8)
    Publisher: 中央大學
    Abstract: Background In the literature, the commonly assumed loading conditions on the proximal femur are hip compression and/or gluteus contractions. However, no study has discussed the influence of muscle forces on failure of distal nail holes and locking screws.
    Relation: CLINICAL BIOMECHANICS????
    Appears in Collections:[Institute of Biomedical Engineering] journal & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML985View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明