中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/47530
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 40203347      在线人数 : 169
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/47530


    题名: 光學遮斷式晶圓定位系統與半導體製程設備之整合;Implementation of a Beam-Breaking Wafer Positioning System and Integration with Semiconductor Manufacturing Equipment
    作者: 李昀諺;Yun-yen Lee
    贡献者: 光機電工程研究所
    关键词: 晶圓定位;光遮斷;人機介面;電腦系統整合程式;System Integration Computer Program;Human Machine Interface;Wafer Positioning;Beam-Breaking
    日期: 2011-10-31
    上传时间: 2012-01-05 11:21:57 (UTC+8)
    摘要: 本論文建立一晶圓定位系統以量測在製程腔體中移動晶圓之圓心位置。定位系統中使用三組光遮斷感測器做為感測模組,排列在機械手臂移動之路徑上,撰寫電腦整合程式依據光學感測模組所接收之時序訊號以計算晶圓圓心。所發展之電腦整合程式包含人機操作介面、並具有判斷晶圓移動方向與缺口/帄邊是否通過感測器之功能。 定位實驗部分,在實驗室以四吋晶圓及八吋晶圓進行實驗,驗證所建立晶圓定位系統之可行性。接著將定位系統與產業用成膜設備整合,並以八吋晶圓及十二吋晶圓進行實驗測試。十二吋晶圓整合測試之定位準確度為0.30mm,定位精確度為0.10mm。 This thesis implements a wafer positioning system for real-time detection of the center position of a moving wafer in a process chamber. Three pairs of optical sensors positioned along an axis transverse to the path of movement of wafer are employed in this wafer positioning system, and a computer program capable of wafer center calculation is developed. The developed computer program computes the wafer center position as well as its moving direction based on the time dependent signals from the optical sensing module. The computer program contains a human machine interface, function of notch/flat judgment and determination of the moving direction. Experiments of 4" and 8" wafer are successfully performed in the laboratory. Then, the wafer positioning system is integrated with a semiconductor manufacturing equipment. The center positions of the 8" and 12" wafers have been measured to understand the precision of the system. According to the experimental results, the accuracy of 12" wafer center detection is 0.30mm and the measurement standard deviation is 0.10mm.
    显示于类别:[光機電工程研究所 ] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML858检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明