中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/50049
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 42142322      在线人数 : 1032
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/50049


    题名: Biomechanical influences of pin placement and elbow angle on hinge alignment and joint distraction of bridged elbow-pin-fixator construct
    作者: Shih,KS;Lin,SC;Chao,CK;Lee,WS;Lu,TW;Hou,SM
    贡献者: 機械工程學系
    关键词: EXTERNAL FIXATION;ARTHROPLASTY;SURGERY;MOTION;AXIS
    日期: 2010
    上传时间: 2012-03-27 17:02:10 (UTC+8)
    出版者: 國立中央大學
    摘要: Joint distraction and mobilization with a hinged external fixator preserves elbow stability and mobility. However, the alignment of both elbow and fixator hinges was the initial prerequisite of the arthrodiatasis technique. The main goal of this study was to numerically evaluate the kinematic influence of the device, surgery, and joint factors on hinge alignment. The kinetic effects of the pins placement and elbow angle on concentric distraction and mobilization were also discussed. A unilaterally hinged elbow-fixator system with a 14 links and 10 degrees-of-freedom was instrumented into a humeroulnar model. The Denavit-Hartenberg method with the homogeneous transformation matrixes was applied to perform kinematic analysis of the linkage system. The predicted results revealed that the concurrence of hinge alignment (i.e., kinematic) and concentric distraction (i.e., kinetic) necessitates two telescopic tubes orthogonal to the elbow hinge. The degrees-of-freedom arrangement of the fixator articulators plays a significant role in hinge alignment. After joint distraction, two hinges might be misaligned due to the difference in the structural rigidity of the pins, fixator, and stiffened elbow. Furthermore, those two prerequisite are interactive and sensitive to elbow angle, fixator design, and pin placement of the bridged elbow-pin-fixator construct. In addition, the ideally concentric distraction might occur only at an elbow angle of 120 degrees owing to the ulnar anatomy. Meticulous planning is necessary for such highly technically demanding surgery. (C) 2009 Published by Elsevier Ltd.
    關聯: JOURNAL OF BIOMECHANICS
    显示于类别:[機械工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML466检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明