    Title: Experimental evaluations of proportional-integral-derivative type fuzzy controllers with parameter adaptive methods for an active magnetic bearing system
    Authors: Tsai,MT;Tung,PC;Chen,KY
    Contributors: 機械工程學系
    Keywords: TUNING SCALING FACTORS;LOGIC CONTROLLER;NONLINEAR CONTROL;PID CONTROLLERS;SUSPENSION;FEEDBACK
    Date: 2011
    Issue Date: 2012-03-27 17:07:07 (UTC+8)
    Publisher: 國立中央大學
    Abstract: This paper deals with the experimental control of a rotating active magnetic bearing (AMB) system using proportional-integral-derivative type fuzzy controllers (PIDFCs) with parameter adaptive methods. Three kinds of parameter adaptive method, including fuzzy tuner, function tuner and relative rate observer, have been proposed in the literature for tuning the coefficients of PIDFCs. However, only a simulation comparison between these methods for control of a second-order linear system with varying parameters and time delay has been done. In general, theoretical models need to be confirmed and modified through experimental results. This paper provides experimental verification by applying PIDFCs with self-tuning algorithms for control of a highly nonlinear AMB system. It is shown that the steady-state error of the AMB system using the function tuner method is lower and the first resonant frequency of the AMB system using the relative rate observer method is higher than the other two methods, and the proportional-integral-derivative controller is quite unstable. The experimental results also show that all of the tuning methods can support a high rotation frequency of the AMB system. In practice, there are only a few differences between the three kinds of parameter adaptive methods.
    Relation: EXPERT SYSTEMS
    Appears in Collections:[Departmant of Mechanical Engineering ] journal & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML501View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明