中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/50655
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78937/78937 (100%)
造访人次 : 39804237      在线人数 : 602
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/50655


    题名: Using Standard Nonenhanced Axial Scans for Cerebral CT Angiography Bone Elimination Feasibility Study
    作者: Huang,A;Lee,CW;Yang,CY;Liu,MY;Liu,HM
    贡献者: 數據分析方法研究中心
    关键词: COMPUTED TOMOGRAPHIC ANGIOGRAPHY;MAXIMUM INTENSITY PROJECTION;INTRACRANIAL ANEURYSMS;DATASET SEGMENTATION;IMAGE QUALITY;SUBTRACTION;REMOVAL;ARTERIES;DSA;MOTION
    日期: 2010
    上传时间: 2012-03-27 17:50:21 (UTC+8)
    出版者: 國立中央大學
    摘要: Objective: To investigate the feasibility of using standard nonenhanced axial-mode scans as precontrast scans for bone elimination in cerebral CT angiography (CTA). Materials and Methods: A consecutive dataset of 32 patients who had both cerebral nonenhanced CT (NECT) (scanned in axial mode) and subtraction CTA (scanned in helical mode) examinations between April and August 2008 were retrospectively analyzed. For each patient, both axial-and helical-mode, NECT scans were processed by using the matched mask bone elimination (MMBE) method. Bone masks generated from axial-and helical-mode NECT scans were quantitatively compared by using overlapping analyses. The diagnostic quality and noise level of the resultant, maximum intensity projection, images by using 2 different bone masks were visually evaluated by 2 neuroradiologists independently using a 5-point scale (inferior, 1; worse, 2; equivalent, 3; better, 4; superior, 5). The effective doses to patients were estimated by using a dose-length product method. Results: Of the 28 (87.5%) patients without intrascan movements, overlap rates between axial-and helical-mode bone masks ranged from 99.2% to 99.9% (mean, 99.7% +/- 0.2%). The mean diagnostic quality and noise level scores of resultant maximum intensity projection images given by 2 neuroradiologists were 3.0 +/- 0.3 and 2.5 +/- 0.5, respectively. The effective dose to patients with a routine brain CTA examination can be reduced from 1.16 to 0.78 mSv (16 cm, field-of-view) by using the proposed method if standard axial-mode NECT scans of the head are readily available. Conclusion: We found that using standard axial-mode NECT scans for bone elimination in helical-mode CTA is feasible. This method can further lower radiation dose without compromising the diagnostic quality.
    關聯: INVESTIGATIVE RADIOLOGY
    显示于类别:[數據分析方法研究中心 ] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML830检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明