中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/52751
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78728/78728 (100%)
造访人次 : 33538183      在线人数 : 2443
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/52751


    题名: Field evaluation of measuring indoor noise exposure in workplace with task-based active RFID technology
    作者: Huang,FC;Shih,TS;Lee,JF;Wang,TS;Wang,PY
    贡献者: 物理學系
    日期: 2010
    上传时间: 2012-06-11 10:42:41 (UTC+8)
    出版者: 國立中央大學
    摘要: This paper describes the research using RFEMS (Radio Frequency Identification Exposure Monitoring System), which is designed by applying the task-based active RFID (radio frequency identification) technology, to measure the indoor noise exposure dose in a workplace. The RFEMS and sound level meter are mounted on the vests of eight workers to carry out on-site field test by monitoring the time activity pattern (TAP), and the noise dose level exposed by the workers. The data are recorded and instantaneously transmitted to a computer to be saved in the server and later compared to those obtained using the standard method. The results that have a 0.909 correlation coefficient (R(2)), and 1.64% average measure error confirm the accuracy of using RFEMS for monitoring TAP. Additionally, the combined use of RFEMS and sound level meter leads to the development of a semi noise dosimetry (SND), a real-time electronic indirect noise dosimetry (REIND), and an equivalent electronic recording indirect noise dosimetry (EEIND). The results obtained using these three devices are well correlated with the results monitored by using a PND (personal noise dosimetry) with correlation coefficients (R(2)) of 0.915, 0.779 and 0.873, respectively. The errors of noise dose expressed in TWA (time weight average) for these three methods are 0.81, 1.57 and 1.23 dBA, respectively; they are well within the general errors of the average dosimetries. These observations indicate that the RFEMS developed in this research is applicable for conducting task-based measurements of indoor noise. It uses a relatively inexpensive sound level meter to measure the noise exposure doses that are comparable to those obtained with a standard dosimetry in addition to monitoring the worker's time activity pattern. The findings will assist in studying the source of long-term noise exposed by workers, and hence this devise is a valuable tool for tracing and monitoring long-term noise exposure with reduced manpower requirements.
    關聯: JOURNAL OF ENVIRONMENTAL MONITORING
    显示于类别:[物理學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML397检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明