中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/53668
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 78818/78818 (100%)
Visitors : 34829720      Online Users : 560
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/53668


    Title: 預鑄施工梁與版間冷縫對T形斷面梁耐震行為之影響;The Influence of the Construction Joint between Precast Beam and Cast-in-Place Slab on the Seismic Behavior of T-Beams
    Authors: 鄭智仁;Jheng,Jhih-Ren
    Contributors: 土木工程研究所
    Keywords: T形斷面梁;耐震行為;交接面剪應力;預鑄施工;施工冷縫;T-Beams;Seismic Behavior;Precast;Construction Joint;Interface Shear Stress
    Date: 2012-08-27
    Issue Date: 2012-09-11 18:05:26 (UTC+8)
    Publisher: 國立中央大學
    Abstract: 本實驗主要是針對有翼版存在的懸臂梁進行受力行為分析,就有無施工冷縫存在與剪力跨度不同進行討論。一般冷縫交接面剪應力檢核之經驗公式是由單向荷載實驗得來,本文亦探討現有規範之經驗公式是否也適用於反覆荷載之地震受力情形。由實驗結果得知,短跨度T形梁(a/d=2.44)存在有澆置冷縫時,比一體澆置試體更容易發生交接面滑移。由於有冷縫存在之試體交接面滑移顯著,負彎矩時更會牽動版筋,使其受拉範圍較大,因此其有效版寬的貢獻為一體澆置試體的1.4倍。另外,就長跨度(a/d=5.46)與短跨度(a/d=2.44)T形梁作比較,發現當試體剪力跨度越長時,抵抗交接面滑移的面積就越大,試體就更不容易發生交接面滑移。由短跨度T形梁(a/d=2.44)交接面剪應力分析結果得知,當試體交接面滑移達0.5mm時,交接面剪應力與規範和經驗公式檢核交接面剪應力的上限值(0.2f'c)相當接近,故0.2f'c應可作為可能產生滑移介面之交接面剪應力上限值。The purpose of this study is to observe the seismic behavior of T-shaped cantilever beams. The study investigates the effect of construction joint and shear span, and verifies the current design equations obtained from monotonic loading experience for evaluating interface shear stress is suitable for that under seismic behavior.The test results indicate that the T-shaped short beam (a/d=2.44) with construction joint slipped more obviously at the interface than the beam without construction joint. According to test results, the effective width of T-beam flange with construction joint is 1.4 time wider than the beam without construction joint .From the comparison between slender beams (a/d=5.46) and short beams (a/d=2.44) it was found that slender beams had less slip effect than short beams. This is because the area of shear resistance at interface for slender beams is larger than short ones.The analytical results of horizontal shear stress obtained from T-shaped short beams (a/d=2.44) also show the horizontal shear stress is closer the upper limit of 0.2f'c specified by current design standards. This limit was concluded form the test result when the interfacial slip movement of 0.5mm was attained. Therefore, the upper shear stress limit of 0.2f'c is verified as design standards specified.
    Appears in Collections:[Graduate Institute of Civil Engineering] Electronic Thesis & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML770View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明