中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/54233
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 41672734      在线人数 : 1410
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/54233


    题名: 利用田口法優化LED路燈散熱鰭片之研究;The study for optimization of LED stree light heat sink by using Taguchi Methods
    作者: 張仁憲;Chang,Jen-Hsien
    贡献者: 光電科學研究所
    关键词: COMSOL Multiphysics;;田口實驗計畫法;直交表;heat;COMSOL Multiphysics;Taguchi method;orthogonal arrays
    日期: 2012-08-08
    上传时间: 2012-09-11 18:40:26 (UTC+8)
    出版者: 國立中央大學
    摘要: 在採用田口實驗計畫法前,本研究參數設計必須採用五個合適的設計參數,分別是鰭片的數目、鰭片的厚度、鰭片的高度、散熱鰭片基底厚度、表面輻射材質等5個可控制因子,每個因子分別有4個水準做參數設計,以降低LED路燈之最高溫度。 選用田口實驗計畫法中的L16(45) 直交表來設定各組參數值,並利用COMSOL Multiphysics模擬軟體實際模擬,將會取得16組模擬結果,再將模擬結果放入直交表中,利用直交表的設計和變異數的分析,找出實驗中主要效應因子為何,以及各個控制因子對回應值的關係,將1024次模擬簡化為16次,讓設計者在較短的時間內即可獲得較佳的設計參數。  初始設計之模擬可得狀況之最高溫度為48.817℃;利用田口實驗計畫之望小特性分析計算後,所得預測最佳設計參數利用COMSOL Multiphysics模擬,可得預測最佳設計參數狀況之最高溫度為37.321℃,鰭片最高溫度獲得明顯下降。本研究確實減少散熱鰭片的開發時間與設計成本,希望對LED路燈散熱設計有所幫助。Before executing Taguchi method, we must estab¬lish the five parameters such as the number of fins and the fin thickness, the fin height, the fin thickness of substrate, the radiation material on surface. First, the above five parameters must be determined. Next, these parameters are divided into four levels separately in order to reduce the maximum temperature of LED street light .  This research using Taguchi Method makes the optimization of LED street light heat sink easier whereas the simulation times of the 5 parameters and the 4 levels of each parameter will be in total 1024 times. We establish a product that can effectively re¬duce simulation times to 16. The maximum temperature of LED street light is lower than all of probable combination exactly.The original design of heat sink without optimization by Taguchi method, the maximum temperature of heat sink is 48.817℃. With the optimal optimization design we can reach the maximum temperature is 37.321℃,the temperature of sink is significantly decreased. Moreover the optimization by Taguchi method design can get the best construction in a short time. Therefore, this research for the cooling components decreases development time and the cost of production. We believe this research will be helpful for thermal design of LED street light.
    显示于类别:[光電科學研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML746检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明