English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 78937/78937 (100%)
造訪人次 : 39423832      線上人數 : 603
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/60408


    題名: 透水性鋪面與傳統鋪面在高溫夏季情況下對氣溫與能源 消耗之影響-以國立中央大學圖書館為例;Permeable Pavement and Traditional Pavement Effect on Air Temperature and Energy Consumption during Hot Summer the Case of National Central University Main Library
    作者: 潘普翠;Paramitha,Putri Adhitana
    貢獻者: 土木工程學系
    關鍵詞: 透水性鋪面;氣溫;能源使用;DesignBuilder;成本;Permeable pavement;air temperature;energy consumption;DesignBuilder;cost
    日期: 2013-07-25
    上傳時間: 2013-08-22 11:36:32 (UTC+8)
    出版者: 國立中央大學
    摘要: 由於都市化造成不透水鋪面的增加及減少自然土地並且減少反射率,增加了熱能
    儲存及能源使用,而造成都市熱島效應。鋪面為都市熱島效應最顯著的影響,減緩熱島效應建議可使用涼鋪面及自然植物來達到環境涼化及節省能源。本研究的目的針對不同類型的透水性鋪面及不同的面積鋪設於建築物周圍,利用空氣和牆面溫度,計算建築物的能源使用,並與傳統的鋪路材料模擬結果進行成本比較。
    本研究實驗區位於新北市新店區,量測參數包含四種材料(密級配瀝青混凝土
    DGAC,透水瀝青混凝土PAC,植草磚GB 及透水連鎖磚PICB)表面溫度與氣象資料,並利用統計分析找出變數之間的相關性;本研究模擬案以國立中央大學圖書館為例,以Design Builder 程式模擬鋪面溫度,並將結果進一步以Design Builder Energy Plus 模擬建築能源使用並計算計算其成本。
    研究結果顯示密級配瀝青混凝土表面溫度為最高,其影響室內和室外溫度,也增
    加冷卻能源的使用。分析結果顯示使用透水性鋪面使用PAC 每年約可減少能源0.17%、GB 約可減少0.735%,而植被每年約可減少0.944%-1.132%。雖然透水性鋪面鋪設成本高於DGAC(PAC 53.2%,GB 86.4%,PI 46.4%),但能源使用之成本較低,與密級配瀝青混凝土總成本差異約可節省PAC 為2.319%、GB 為3.490%及PI 為1.700%。
    The urbanization process increases artificial surfaces and less natural vegetation,decreases the albedo, increases metabolic heat and energy consumption, resulting in heat
    island effect. Pavements are found to be a significant contributor to the Urban Heat Island.
    Cool pavements and vegetation are suggested as a strategy to mitigate heat island effect bycooling the environment and saving energy. The purpose of this study is to discover the effect of different types of permeable pavement and different pavement area covering the building on air and wall temperature, building‘s cooling energy consumption, and the costs comparison of permeable pavements with conventional paving materials.
    Four types of pavement (dense grade asphalt pavement/DGAC, permeable asphalt pavement/PAC, concrete, grass block/ GB, and permeable interlocking concrete block/PICB)from Xindian are used in simulation. Xindian site measurement is conducted to collect meteorological and pavement surface temperature data. Statistical analysis is used to find the
    correlation between variables and to develop the pavement surface temperature model applied on National Central University (NCU) main library as the case study for the simulations using Computational Fluid Dynamics (CFD) simulation package in DesignBuilder. The result is
    further used in the building energy consumption simulations using EnergyPlus in DesignBuilder, and then used to calculate the cost.
    The result shows DGAC gives the highest temperature and impact on the outdoor and indoor temperature, and also increases cooling energy consumption. Analysis results showed differences caused by using permeable pavements or by increasing vegetation area. Utilizing permeable pavement can decrease energy consumption 0.170% (PAC) until 0.735% (GB) per year. And vegetation also can decrease 0.944%-1.132% per year. Even permeable installation cost is higher than DGAC (PAC 53.2%, GB 86.4%, PI 46.4%), energy efficiency cost make it cheaper. The total cost differences with DGAC is just 2.319% for PAC, 3.490% for GB, and 1.700% for PI.
    顯示於類別:[土木工程研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML783檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明