中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/60578
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78937/78937 (100%)
造访人次 : 39183438      在线人数 : 450
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/60578


    题名: 利用混合吸附劑故項萃取法結合液相層析串聯質譜技術檢測水樣中人工代糖的濃度
    作者: 李岱庭;Dai-Ting
    贡献者: 化學學系
    关键词: 人工代糖;液相層析儀;串聯質譜
    日期: 2013-07-05
    上传时间: 2013-08-22 11:41:08 (UTC+8)
    出版者: 國立中央大學
    摘要:  本研究使用自行填充的HLB (Hydrophilic-Lipophilic Balance) 及C18混合吸附劑進行固相萃取 (Solid Phase Extraction, SPE) ,並使用液相層析串聯質譜儀 (Liquid Chromatography - Tandem Mass Spectrometry, LC-MS/MS)進行水樣中三氯蔗糖及阿斯巴甜的偵測,偵測極限分別為14 ng/L與10 ng/L,定量極限分別為120 ng/L與78 ng/L。本研究同時使用"面中心中央合成設計 (Face-Centered Center Composite Design, FCCCD) 進行多因子實驗條件最佳化法,可減少實驗次數以及可觀察因子間的交互作用關係。最佳化條件如下:固相萃取匣吸附劑重量為180 mg,比例為HLB:C18 = 3:1,進樣流速為2.5 mL/min,沖提溶劑為甲醇,體積為15 mL。使用Mandel’s Fitting Test及Lack of Fit測試檢量線及實驗設計模型的適用性,並進行再現性測試相對標準偏差均小於7%。
      本研究檢測自來水,瓶裝水,地下水與河流水水樣,這是國內首次有關人工代糖在飲用水與環境水樣中的檢測結果,其中三氯蔗糖濃度為3.6 μg/L至31 μg/L,阿斯巴甜皆無檢出,除一個河流水水樣濃度為2.7 μg/L;本研究所開發混和型固相萃取搭配液相層析串聯質譜儀具有良好的靈敏度及穩定性,可應用於不同水樣來源的濃度檢測。
    In this study hybrid-SPE was applied to extract Artificial Sweeteners (ASs) from various water samples. Combination of HLB (Hydrophilic-Lipophilic Balance) and ENVI-C18 was applied as the adsorbent for hybride-SPE, and the factors affecting the extraction efficiency of the analytes were optimized by a Face-Centered Central Composite Design (FCCCD). Optimized extraction conditions were as follows: adsorbent ratio HLB: ENVI-C18 = 3:1, adsorbent amount: 180 mg, sampling flow rate: 2.5 mL/min, and elution solvent: 15 mL methanol. The SPE extractant was then analyzed by HPLC – MS / MS. Limits of quantitation (LOQ) were 120 ng/L and 78 ng/L for sucralose and aspartame, respectively. In this study we analyzed tap water, bottled water, groundwater and river water samples, this is the first report of ASs detection in Taiwan. Sucralose concentrations were ranged from 3.6 to 31 μg/L, and aspartame was only detected in one river water sample, its concentration was 2.7 μg/L. In this study, efficient and reliable hybrid-SPE coupled with HPLC-MS/MS procedure was developed, which is sensitivity, stability, and can be applied in analysis of ASs in various of water samples.
    显示于类别:[化學研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML671检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明