    題名: 以矽烷化衍生試劑搭配氣相層析質譜儀於線上衍生法快速分析環境水樣中三氯沙之濃度;Determination of Triclosan in Water Samples by On-line Derivatizaion coupled with Gas Chromatography-Mass Spectrometry
    作者: 鄭喬尹;Chiao-yin Cheng
    貢獻者: 化學研究所
    關鍵詞: 線上衍生化;氣相層析質譜儀;derivatization;gas chromatography-mass spectrometry
    日期: 2009-06-18
    上傳時間: 2009-09-22 10:19:57 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 本篇研究主要是以氣相層析質譜儀的大體積進樣裝置搭配矽烷化衍生試劑進行注射埠之線上衍生化技術,有效檢測環境水樣中的三氯沙(TCS)與甲基三氯沙(MTCS)。在衍生化的過程中,針對注射埠中的反應溫度及時間進行最佳化探討,以MTBSTFA作為衍生試劑,衍生反應溫度及時間分別為120℃和2分鐘,可將TCS轉化成TCS-TBDMS衍生物,在進行GC檢測時,能與MTCS完全分離。線上衍生技術步驟簡單且能迅速地分析待測物,簡化傳統衍生反應的過程與衍生試劑用量,並利用固相萃取技術作為水樣的前處理方法。待測物在去離子水中之回收率為104%以上,相對標偏差值(RSD)則都在7%以下。對台灣不同環境樣品進行檢測,待測物的回收率大多可在70%以上,相對標準偏差在12%以下,而本方法之定量偵測極限(LOD)對三氯沙及甲基三氯沙分別為0.9 ng/L與1.0 ng/L。針對安平污水處理廠之進流水中,檢測出三氯沙的濃度範圍為35 ng/L至278 ng/L,放流水則為78 ng/L以下;豐原地區表面水水樣品與中央大學百花川水樣中觀察到微量的三氯沙存在,濃度範圍約1~70 ng/L之間。在所有環境水樣中均未檢測到甲基三氯沙。除此之外,本篇研究也針對市售的個人護理產品(如洗面乳、牙膏和洗手乳)以超音波震盪的萃取方式進行檢測,三氯沙的濃度範圍為0.07% ~ 0.28%,均在政府的規範內。 A rapid injector-port derivatization with gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the determination of triclosan (TCS) and methyl triclosan (MTCS) in various environmental water samples. The parameters related to the derivatization process (i.e., injection-port temperature and reaction time) were optimized. TCS was converted into the tert-butydimethylsilyl (TBDMS) derivative by MTBSTFA as silyation reagent holding 2 min in injection-port at temperature 120℃. Derivative TCS-TBDMS can be separated from MTCS in GC analysis. This technique simplified the derivatization procedure and increase sensitivity. Solid-phase extraction (SPE) method was used to cleanup and concentrate analytes from wastewater samples. The limits of detection of TCS and MTCS were 0.9 and 1.0 ng/L, respectively. The recoveries from the spiked water samples ranged from 48 – 119% with relative standard deviation (RSD) less than 16% at the 250 ng/L level. Only TCS was detected in wastewater and surface water samples, and concentrations ranged from 35 - 287 ng/L in influents, ND - 78 ng/L in effluents, 1 - 70 ng/L in surface water samples. No MTCS was detected in all samples. In this study, we also detected the personal care products (i.e., toothpaste, facial Cleansing cream and handwashs) using ultrasonic extraction to confirm the content of triclosan. The recoveries of triclosan from the spiked PCP samples ranged from 94 – 100% with relative standard deviation (RSD) less than 12%, and the contents of triclosan ranged from 0.07% - 0.28%.
    顯示於類別:[化學研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明