中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/72243
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78852/78852 (100%)
造访人次 : 37838141      在线人数 : 496
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/72243


    题名: 以核方法化的相關濾波器之物件追蹤方法 實作眼動儀系統;Implementation of an eye-tracking system using Kernelized Correlation Filter.
    作者: 鄭博仁;Zheng,Bo-Ren
    贡献者: 資訊工程學系
    关键词: 眼動儀;相關濾波器;核方法;eye-tracking;correlation filter;Kernel method
    日期: 2016-08-18
    上传时间: 2016-10-13 14:34:29 (UTC+8)
    出版者: 國立中央大學
    摘要: 近年來,眼動儀已經是一個常用於心理學分析、疾病分析、廣告配置分析等等領域的一套設備。在本研究中,我們自製了一套穿戴式的眼動儀系統。使用Microsoft HD-6000 相機,改造成可清楚拍攝虹膜與瞳孔邊界的紅外光相機,搭配專用連接器可將攝影機置於眼鏡的鏡框上,讓攝影機能夠拍攝到眼睛的紅外光影像。眼動儀系統最主要的功能是能夠正確的偵測瞳孔的位置,本研究方法使用了以核方法的相關濾波器之物件追蹤演算法實作瞳孔追蹤功能,使用追蹤演算法找出大致上的瞳孔中心位置,並且搭配圓形擬合方法找出正確的瞳孔圓心及半徑,在搭配投影轉換,將瞳孔的位置轉換到實際所看的螢幕位置。在實驗結果中,與手動定位的瞳孔圓心的誤差平均只有2.02 個pixel,半徑大小的誤差為1 個pixel,且在執行速度上,處理一張影像只需要0.0295 秒,相當於每秒可執行33.95 張影像,執行速度超過一般攝影機所能提供的每秒30 張影像,是一套計算快速且準確的眼動儀系統。;In recent years, eye-tracking is already used in areas like psychology, human-computer interface and e-learning. In this study we made a wearable eye-tracking system.We hand-made a IR camera by modifying a commercially available webcam(MS HD-6000) and mounted it to a customized glasses frame. Such device is a wearable eye-tracking system which is able to record a clear video of eye movement when the user wears the glasses frame. The most important feature of an effective eye-tracker is to locate and track the pupil movement correctly in realtime. In this research, we used Kernelized Correlation Filter to implement pupil location tracking. By using KCF and a self-developed circle-fitting algorithm, we are able to detect and track the pupil location accurately. In experimental results,compare manual and automatic detection of the pupil center, the average error of manual and automatic detection pupil center is 2.02 pixel, and the average error ofpupil radius is 1.1 pixel. In terms of execution speed, it only takes 0.0295 second to process an image, which is equivalent to 33.9 FPS (frame per second). Therefore,our eye-tracking system is fast enough to fulfill the real-time requirement and is ready to be used in many practical situations.
    显示于类别:[資訊工程研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML295检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明