中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/72595
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 41641145      在线人数 : 1389
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/72595


    题名: 掃描式白光干涉儀應用於局域性表面電漿共振量測;Application of White-light Scanning Interferometry on Localized Surface Plasmon Resonance Sensor
    作者: 王懷逸;Wang, Huai-Yi
    贡献者: 光電科學與工程學系
    关键词: 掃描式白光干涉儀;局域性表面電漿共振效應;時域式頻譜儀;White-light Scanning Interferometry;LSPR;FFT;Time-domain Spectroscopy
    日期: 2016-12-02
    上传时间: 2017-01-23 16:33:55 (UTC+8)
    出版者: 國立中央大學
    摘要: 本論文利用掃描式白光干涉技術原理搭配快速傅立葉轉換法(Fast Fourier Transform, FFT)將時域干涉信號,藉由傅立葉振幅得到頻譜資訊,將其應用於局域性表面電漿共振效應(Localized Surface Plasmon Resonance, LSPR)之檢測,藉由LSPR吸收頻譜因環境折射率改變而產生紅移現象作為檢測依據。本文也利用質心演算法(Spectral Centroid Algorithm)來改善PZT(Piezoelectric Transducer)掃描長度限制頻譜解析度之缺點。
      針對檢測系統可能造成的誤差來源,包含了波數精確性、光源照度不均勻之問題,進行研究與改善。波數精確性方面,利用一高通濾波片做為量測樣品,並將掃描式白光干涉儀與光譜儀(Hitachi U-4100)的量測結果作比較,當PZT移動一步的距離為71 nm時,與光譜儀量測之頻譜最為匹配,其平均差異為1.04 %;光源照度不均勻之問題,經由程式修正可將照度均勻度(Uniformity)約41.34 %改善至92.49 %。
      在利用LSPR量測環境折射率變化方面,其檢測極限(Limit of Detection, LOD)可達1.2"×" 10-3 RIU (Refractive Index Unit);應用於生醫檢測方面,本文使用rs242557 tau基因做為目標分析物,對其濃度之檢測極限為15 pM。
    ;This article aims to set up a biosensor based on white-light scanning interferometry (WLSI) and applies to localized surface plasmon resonance (LSPR) sensor. In the WLSI system, the amplitude changes, as functions of wavelength, is retrieved by means of Fourier transform of the correlograms (interferograms in vertical direction). The Fourier amplitude method is capable to measure environmental changes in refractive index which results in a red shift of the amplitude (or spectrum) of gold nanoparticles (GNPs) solution. Meanwhile, the article shows that the performance of a spectrometer with poor spectral resolution is improved by the spectral centroid algorithm significantly because more data points (wavelengths) are considered for signal-to-noise ratio improvement
    Additionally, the sources of errors in the WLSI system, inclusive of the accuracy of wave-number and illumination non-uniformity, are improved. We use the spectrum of an edge filter as a check of the wavenumber accuracy. The result shows the best match with frame interval of 71 nm. In comparison to a spectrometer, the average spectrum error is 1.04 %. The illumination uniformity is also improved from 41.34 % to 92.49 % by the program correction.
    A method to measure the refractive index variation in the WLSI system is described in the article. The limit of detection (LOD) is 1.2"×" 10-3 RIU (Refractive Index Unit). The bio-applicability was investigated using the rs242557 tau gene, an Alzheimer′s and Parkinson’s disease biomarker. The LOD was calculated as 15 pM.
    显示于类别:[光電科學研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML503检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明