中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/73091
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 78937/78937 (100%)
Visitors : 39640847      Online Users : 411
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/73091


    Title: 運用單壁奈米碳管與鉍奈米粒子/單壁奈米碳管修飾玻璃碳電極進行鉛之伏安法分析;Voltammetric determination of lead using single-walled carbon nanotubes and bismuth nanoparticles / single-walled carbon nanotubes composite-modified electrode
    Authors: 廖淑君;Liao, Shu-Jun
    Contributors: 環境工程研究所
    Keywords: ;奈米碳管;線性掃描伏安法;;干擾;bismuth;carbon nanotube;linear sweep voltammetry;lead;interference
    Date: 2017-01-23
    Issue Date: 2017-05-05 17:44:15 (UTC+8)
    Publisher: 國立中央大學
    Abstract: 鉍(bismuth, Bi)由於擁有較汞更少的毒性以及對環境更具有友善之特性,近年來被考慮為取代汞電極作為電極材料之一。本研究利用電鍍的方式將鉍電鍍於單壁奈米碳管修飾電極上,並使用單壁奈米碳管修飾電極(SWCNT/GCE)以及鉍/單壁奈米碳管修飾電極(Bi/SWCNT/GCE)搭配線性掃描伏安法進行水中鉛(lead, Pb)之分析。透過參數選擇,最佳電解液為0.1 M醋酸緩衝溶液(ABS),掃描範圍為 -0.8至0伏特,掃描速率為0.2 V/s,最低偵測極限為100 ppb。水中有許多與鉛共存的物質會造成鉛偵測的干擾,因此鄰苯二甲酸氫鉀(KHP)作為水中有機物,另外加入三價鉻、六價鉻與銅於電解液中,並對鉛偵測之干擾現象作探討。當KHP存在於水中,並不會影響Pb的峰電流值。而Cr3+和Cr6+則分別造成Pb的峰電流值下降或上升的情況。由於Cu與Pb競爭碳管上的活性位置會導致Pb的峰電流值下降。本研究使用EDTA降低Cu的干擾,發現EDTA不僅能夠去除Cu的干擾,且會與Pb進行螯合。推測EDTA可用於低Cu濃度的水樣中偵測Pb的存在。;Bi is less toxic than mercury, thus it has been considered as an environmental friendly alternative for mercury-based electrodes. The objective of this paper is to analyze Pb via linear sweep voltammetry (LSV) using single-walled carbon nanotubes (SWCNT/GCE) and bismuth nanoparticle/single-walled carbon nanotubes (Bi/SWNCT/GCE) composite modified glassy carbon electrodes. Bi could be deposited on SWCNT via electroplating. The proper scanning conditions of voltammetry, electrolytes is 0.1 M acetate buffer solution (ABS), scan potential range from -0.8 to 0 V, scan rate is 0.2 V/s, and the detection limit of Pb can achieve 100 ppb. Since there are usually various heavy metal ions and organic matter co-existed in wastewater, the interference, such as potassium hydrogen phthalate (KHP), Cr3+, Cr6+, and Cu2+ would be examined. KHP showed no effects on the Pb peak current. Cr3+ and Cr6+ would decrease and increase the peak current of Pb, respectively. Cu would decrease the Pb peak current for it might compete the active sites of carbon nanotubes. EDTA could be used to eliminate the interference of Cu, but it would also chelates with Pb. It was found that 0.001 mM EDTA can eliminate the interference of Cu, but peak current of Pb might be also decreased to 50%. Thus, EDTA could only be used at low Cu concentration to detect Pb.
    Appears in Collections:[Graduate Institute of Environmental Engineering ] Electronic Thesis & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML444View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明