    題名: 鋼筋混凝土擴柱補強後新舊混凝土滑移對結構物耐震性能影響之探討;An Investigation of Buildings Seismic Performance of Bond Slip in The Interface Between New And Old Concrete Retrofitted with RC Jacketing
    作者: 林彥谷;YAN-GU LIN
    貢獻者: 土木工程研究所
    關鍵詞: 梁柱接頭;橫向梁;混凝土擴柱補強;接頭剪力;RC Jacketing;Stub;Beam-Column Joints;Joint Shear
    日期: 2005-07-07
    上傳時間: 2009-09-18 17:17:18 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 本實驗主要針對非韌性梁柱內接頭在未受到任何損傷前,採用普通強度混凝土擴柱補強之,藉由擴柱補強後分析其所增加之接頭剪力強度,以及探討擴柱補強後之現象如橫向梁所造成之影響、新舊混凝土不一致產生介面滑移之影響、強度及勁度之提昇優劣比較、並且驗證現今評估接頭剪力強度模式的準確性。 本實驗以內接頭為探討對象,一支原型試體及三支RC擴柱補強試體。其中原型試體及一支擴柱補強試體設計成接頭剪力破壞型式,另一支擴柱補強試體之接頭兩側有橫向梁圍束,最後一支擴柱補強試體設計成“恰好”梁撓曲破壞形式。實驗結果顯示,非韌性梁柱內接頭經由混凝土擴柱補強後,其剪力強度、勁度皆有效提升,而橫向梁對於新舊混凝土剝離滑移是有遏止的功效,並且會增加接頭剪力強度,以及減緩接頭破壞後強度的衰減速率。以現行之評估方式,Hakuto剪力衰減模式較適合用來分析原型試體,對於擴柱試體有高估之情形。 The purpose of this study is to observe the results for concrete jacketing with the general strength concrete for non-ductile interior beam-column joints. In the study, the increased joint shear, the influence of stub, the bond slip between new and old concrete interface, and stiffness enhancement were discussed. Meanwhile, the accuracy of the current assessment of joint shear models is verified. The test is based on interior beam-column joints. The specimens comprise one prototype interior beam-column joint and three retrofitted specimens with RC jacketing. Prototype and one RC jacketing specimens were designed to joint shear failure, one was confined by two side beam stubs for simulating the interior joints with beams in two sides, and the other RC jacketing specimen was designed to “just” beam flexural failure. From the test results, it was found that the retrofitted specimens are superior to the benchmark specimens in strength, stiffness. The beam stubs can prohibit the bond slip between new and old concrete interface and slow down the behavior of shear degradation. It is suitable to analyze the prototype specimen by means of the Hakuto shear degradation model. However the shear degradation model overestimated the joint shear for RC jacketing specimens.
    顯示於類別:[土木工程研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明