參考文獻 |
[1] 唐治平、李維森等(2001),「橋梁結構耐震、隔震及減震技術之應用研究」,行政院公共工程委員會研究報告第123號。
[2] Abrishambaf, A. and Ozay, G. (2010) “Effects of isolation damping and stiffness on the seismic behaviour of structures”, World Scientific and Engineering Academy and Society (WSEAS), pp. 76-81.
[3] Robinson, W. H. (1982) “Lead-Rubber Hysteretic Bearings Suitable For Protecting Structures During Earthquakes”, Earthquake Engineering and Structural Dynamics, Vol. 10, pp. 593-604.
[4] Mokha, A. S., Constantinou, M. C., Reinhorn , A. M. and Zayas, V. (1991) “Experimental study of friction pendulum isolation system” , Journal of Structure Engineering, ASCE, Vol. 117, pp. 1201-1217.
[5] Wang, Y. P., Chung, L. L., and Liao, W. H. (1998) “Seismic response analysis of bridges isolated with friction pendulum bearings”, Earthquake Engineering and Structural Dynamics, Vol. 27, pp. 1069-1093.
[6] Lee, G.C. and Liang, Z. (2003) “A Sloping Surface Roller Bearing and its lateral Stiffness Measurement”, In Proceedings of the 19th US-Japan Bridge Engineering Workshop,Tsukuba, Japan.
[7] Tsai, M. H., Wu, S. Y., Chang, K. U. and Lee, G. C. (2007) “Shaking table tests of a scaled bridge model with rolling-type seismic isolation bearings”, Engineering Structures, Vol. 29, pp. 694-702.
[8] 李維森 (1997),「線性液體阻尼器於橋梁耐震工程上之應用研究」,博士論文,國立中央大學土木工程研究所,中壢。
[9] 曾義軒 (2004),「黏性阻尼器於橋梁隔減震之應用研究」,碩士論文,國立台灣科技大學營建工程系,台北。
[10] 陳柏全 (2012),「隔震橋梁之最佳化結構控制」,博士論文,國立中央大學土木工程研究所,中壢。
[11] Whiiaker, A. S. , Constantinou, M. C. and Kircher. C. A. (1996) “Seismic rehabilitation using supplemental damping systems” World Conference on Earthquake Engineering. pp.219-226
[12] Spencer, B. F. and Nagarajaiah, S. (2003) “State of the Art of Structural Control. ”Journal of Structural Engineering, ASCE,129(7), pp.845-856
[13] Constantinou, M. C., Soong, T. T. and Dargush, G. F., (1998) “ Passive Energy Dissipation Systems For Structural Design And Retrofit”, MCEER Monograph, Multidisciplinary Center for Earthquake Engineering Research, Buffalo, New York
[14] Constantinou, M. C. and Symanss, M. D (1992), “Experimental and analytical investigation of seismic response of structure with supplemental fluid viscous dampers ”National Center for Earthquake Engineering Research , Technical Report NCEER-92-0032, New York
[15] Constantinou, M. C. and Symanss, M. D (1993), “Experimental study seismic response of buildings with supplemental fluid damping” The Structural Design of Tall Buildings, Vol. 2, pp. 93-132
[16] Constantinou, M. C. (1994) “Application of fluid viscous dampers to earthquake resistant design” National Center for Earthquake Engineering and Research; pp. 73–80
[17] Constantinou, M. C., Symans, M. D, Tsopelas, P., and Taylor, D. P. (1993) “Fluid viscous dampers in application of seismic energy dissipation and seismic isolation” Proc., ATC-17-1 Seminar of Seismic Isolation, Passive Energy Dissipation, and Active Control, 2,581-591.
[18] Taylor, D. P. (1992) “Fluid Dampers for Applications of Seismic Energy Dissipation and Seismic Isolation” Eleventh World Conference on Earthquake Engineering Research, State University of New York at Buffalo
[19] Whittaker, A.S.,Constantinou, M.C. and Kircher C.A. (1996),“Seismic Rehabilitation Using Supplemental Damping Systems” Eleventh World Conference on Earthquake Engineering, paper No. 430,ISBN:0-08-042822-3
[20] Housner, G. W. (1963), “The Behavior of Inverted Pendulum Structures During Earthquakes”, Bulletin of the Seismological Socity of America, Vol. 53, No. 2, pp. 403-417.
[21] Meek, J. W. (1978), “Dynamic Response of Tipping Core Building”, Earthquake Engineering and Structural Dynamics, Vol. 6, pp. 437-454.
[22] Priestley, M. J. N., Evison, R. J. and Carr, A. J. (1978), “Seismic Response of Structures Free to Rock on Their Foundations”, Bulletin of the New Zealand National Society for Earthquake Engineering, Vol. 11, No. 3, pp. 141-150.
[23] Yim, C. S., Chopra, A. K. and Panzien, J. (1980), “Rocking Response of Rigid Blocks to Earthquake”, Earthquake Engineering and Structural Dynamics, Vol. 8, pp. 565-587.
[24] Psycharis, I. N. and Jennings, P. C. (1983), “Rocking of Slender Rigid Bodies Allowed to Uplift”, Earthquake Engineering and Structural Dynamics, Vol. 11, pp. 57-76.
[25] Chopra, A. K. and Yim, S. C. S. (1985), “Simplified Earthquake Analysis of Structures with Foundation Uplift”, Journal of Structural Engineering, ASCE, Vol. 111, No. 4, pp. 906-930.
[26] Sakellaraki, D., Watanabe, G. and Kawashima, K. (2005), “Experimental Rocking Response of Direct Foundation of Bridges,” Second International Conference on Urban Earthquake Engineering, Tokyo Institute of Technology, Tokyo, Japan, March7-8, pp. 497-504.
[27] Sakellaraki, D. and Kawashima, K. (2006), “Effectiveness of Seismic Rocking Isolation of Bridges Based on Shake Table Test,” First European Conference on Earthquake Engineering and Seismology, Geneva, Switzerland, September 3-8.
[28] Kawashima, K., Watanabe, G., Sakeraraki, D. and Nagai, T. (2005), “Rocking Isolation of Bridge Foundations,” 9th World Seminar on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, Kobe, Japan, June 13-16.
[29] Anastasopoulos, I., Loli, M., Georgarakos, T. and Drosos, V. (2013), “Shaking Table Testing of Rocking—Isolated Bridge Pier on Sand”, Journal of Earthquake Engineering., Vol. 17, pp. 1-32.
[30] Kawashima, K. and Nagai, T. (2006), “Effectiveness of Rocking Seismic Isolation on Bridge,” 4th International Conference on Earthquake Engineering, Taipei, Taiwan, October 12-13.
[31] Apostolou, M., Gazetas, G. and Garini, E. (2006), “Seismic Response of Slender Rigid Structures with Foundation Uplifting,” Soil Dynamics and Earthquake Engineering, Vol. 27, pp.642-654.
[32] Raychowdhury, P. and Hutchinson, T. C. (2009), “Performance Evaluation of a Nonlinear Winkler-Based Shallow Foundation Model using Centrifuge Test Results,” Earthquake Engng Struct. Dyn., Vol. 38, pp. 679-698.
[33] Deng, L., Kutter, B. L. and Kunnath, S. K. (2012), “Centrifuge Modeling of Bridge Systems Designed for Rocking Foundations,” J. Geotech. Geoenviron. Eng., Vol. 137, No. 3, pp. 335-344.
[34] Hung, H. H., Liu, K.Y., Ho, T. H. and Chang K. C. (2010), “An Experimental Study on the Rocking Response of Bridge Piers with Spread Footing Foundations,” Earthquake Engineering and Structural Dynamics, Vol. 40 pp. 749-769.
[35] 洪曉慧、張國鎮、劉光晏、何姿慧(2008),「直接基礎之搖擺實驗與分析」,國家地震工程研究中心,報告編號:NCREE-08-040。
[36] 黃敏彥 (2013),「橋梁直接基礎搖擺之極限分析」,碩士論文,國立中央大學土木工程研究所,中壢。
[37] 周煌鈞 (2015),「橋梁直接基礎搖擺試驗」,碩士論文,國立中央大學土木工程研究所,中壢。
[38] Kawashima, K. and Unjoh, S. (1991), “Overturning of Rigid Foundation Resting on Ground with Insufficient Yield Strength,” Civil Engineering Journal, Japan, Vol. 33, No. 3, pp. 54-59.
[39] Kawashima, K., Unjoh, S. and Mukai, H. (1994), “Inelastic Rocking of Direct Foundation During an Earthquake,” Civil Engineering Journal, Japan, Vol. 36, No. 7, pp. 50-55.
[40] Taylor Devices, Inc. http://www.taylordevices.com/
[41] Allotey, N. and Naggar EI, M, H.(2003),”Analytical Moment-Rotation Curves for Rigid Foundations Base on Winkler Model,” Soil Dynamics and Earthquake Engineering, Vol. 23, pp. 367-381.
[42] 日本道路協會 (1997),「道路橋の耐震設計に関すゐ資料」,丸善株式會社,東京。
[43] 日本道路協會 (2012),「道路橋示方書IV 下部構造編」,丸善株式會社,東京。
[44] Raychowdhury, P. (2008), Nonlinear Winkler-Based Shallow Foundation Model for Performance Assessment of Seismically Loaded Structures”, Doctoral Thesis, Department of Civil and Environmental Engineering, University of California, San Diego. |