In the microgrid, Power supply voltage occur voltage sag or a swell due to energy instability or other external factors, or even a more serious power quality problem. Therefore, the serial active power filter can be used to improve these problems.Serial active power filter main purpose of filter out the interference and accurately compensate the voltage , so that the load voltage can be consistent with that before the interference. Therefore, it is also called the Dynamic Voltage Restorer.The main hardware is constructe in a three-phase four-wire converter, so how to use the calculation method and realize the effect of the series active power filter compensator through the hardware system is a major research focus.
Through the experimental results of this paper, it is observed that when series active power filter occur voltage sag and other interference,has the compensation of immediacy and accuracy ,so that the load voltage is kept within a reasonable range, load not Power supply interference is affected.
This paper introduces the operation principle and calculation method of the series active power filter, and then verifies the feasibility of the algorithm through the simulation and test platform,and further realizes the hardware system.
|
參考文獻 |
[1] 黃靖智,「分散式電源串聯型併聯模組之均載控制策略」,國立中山大學電機工程學系碩士論文,中華民國九十七年九月。
[2] 電力品質不良因素與管制標準研究-旋宇工程顧問有限公司及中華技術學院電機工程系產學合作報告書。
[3] IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, IEEE Std 519-2014.
[4] IEEE Recommended Practice for Monitoring Electric Power Quality, IEEE Std 1159-2009.
[5] Deepa Francis, Tomson Thomas , “Mitigation of voltage sag and swell using dynamic voltage restorer,” 2014 Annual International Conference on Emerging Research Areas: Magnetics, Machines and Drives (AICERA/iCMMD), Kottayam, India , July 2014.
[6] V. Ansal, K. Ravikumar, P. Parthiban “Transformerless Dynamic Voltage Restorer for voltage sag mitigation,” Biennial International Conference on Power and Energy Systems: Towards Sustainable Energy, Bangalore, India, Jan. 2016.
[7] A. Mahmoud, Y. Amr, Tarek, “Dynamic Voltage Restorer (DVR) for Voltage Sag Mitigation,” International Journal on Electrical Engineering and Informatics ‐ Volume 3, Number 1, 2011.
[8] T. Paulraj, P. Rajkumar, “Voltage Unbalance Mitigation Using Positive Sequence Series Compensator”, IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE), vol.9, Issue 3 Ver. I (May –Jun. 2014), PP 98-103.
[9] 羊宣銘,「電網同步之鎖相迴路控制器的分析與設計」,國立交通大學電控工程究所碩士論文,中華民國一百零二年七月。
[10] P. Rodriguez, A. Luna, M. Ciobotaru, R. Teodorescu, F. Blaabjerg, “Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions,” Annual Conference on IEEE Industrial Electronics, Paris, France, Nov. 2006.
[11] P. Rodríguez, R. Teodorescu, I. Candela, A. V. Timbus, M. Liserre, F. Blaabjerg, “New positive-sequence voltage detector for grid synchronization of power converters under faulty grid conditions,” IEEE Power Electronics Specialists Conference, Jeju, South Korea, June 2006.
[12] W. V. Lyon, Application of the Method of SymmetricalComponents, New York: McGraw-Hill, 1937.
[13] Pedro Rodríguez, Alvaro Luna, Raúl Santiago Muñoz-Aguilar, Ion Etxeberria-Otadui, and Remus Teodorescu , “A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions,” IEEE Transactions on Power Electronics ‐ vol.27, no.1, pp. 99-112, June 2011.
[14] A. Khoshkbar Sadigh, K. M. Smedley, “Review of voltage compensation methods in dynamic voltage restorer (DVR),” IEEE Power and Energy Society General Meeting,San Diego, CA, USA, July 2012.
[15] 吳孟倫,「結合雙二階廣義積分法與鎖頻迴路為基礎之串聯式主動電力濾波器設計」,國立中央大學電機工程學系碩士論文,中華民國一百零六年六月。
[16] Santosh Kumar Singh, Sudhir Kumar Srivastava, “Enhancement in power quality using dynamic voltage restorer (DVR) in distribution network,” International Conference on Innovations in Information, Embedded and Communication Systems, Coimbatore, India, March 2017.
[17] 張家豪,「一種動態電壓恢復器之研製」,國立中山大學電機工程學系碩士論文,中華民國九十三年七月。
|