參考文獻 |
1. Vu, C.A., et al., Signal Enhancement of Silicon Nanowire Field-Effect Transistor Immunosensors by RNA Aptamer. ACS Omega, 2019. 4(12): p. 14765-14771.
2. Dmitri Ivnitski, I.A.-H., Plamen Atanasov, Ebtisam Wilkins, Biosensors for detection of pathogenic bacteria. Biosensors & Bioelectronics, 1999. 14: p. 599-624.
3. Forster, R.J., P. Bertoncello, and T.E. Keyes, Electrogenerated chemiluminescence. Annu Rev Anal Chem (Palo Alto Calif), 2009. 2: p. 359-85.
4. Lequin, R.M., Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA). Clin Chem, 2005. 51(12): p. 2415-8.
5. Englebienne, P., A. Van Hoonacker, and M. Verhas, Surface plasmon resonance: principles, methods and applications in biomedical sciences. Spectroscopy, 2003. 17: p. 255-273.
6. Georgios Tsekenis, G.-Z.G., Frank Davis, Paul A. Millner, Tim D. Gibson, and Se´amus P. J. Higson, Label-less Immunosensor Assay for Myelin Basic Protein Based upon an ac Impedance Protocol. Analytical Chemistry, 2008. 80(6): p. 2058-2062.
7. 吳民耀、劉威志, 表面電漿子理論與模擬. 物理雙月刊, 2006. 28(2): p. 486-496.
8. 邱國斌、蔡定平, 金屬表面電漿簡介. 物理雙月刊, 2006. 28(2): p. 472-485.
9. Liu, B.D., Y.K. Su, and S.C. Chen, Ion-sensitive field-effect transistor with silicon nitride gate for pH sensing. International Journal of Electronics, 1989. 67(1): p. 59-63.
10. Kojima, A., et al., Protein Sensor Using Carbon Nanotube Field Effect Transistor. Japanese Journal of Applied Physics, 2005. 44(4A): p. 1596-1598.
11. Chen, K.-I., B.-R. Li, and Y.-T. Chen, Silicon nanowire field-effect transistor-based biosensors for biomedical diagnosis and cellular recording investigation. Nano today, 2011. 6(2): p. 131-154.
12. Cui, Y., et al., Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species. Science, 2001. 293: p. 1289-1292.
13. Lu, N., et al., Label-free and rapid electrical detection of hTSH with CMOS-compatible silicon nanowire transistor arrays. ACS Appl Mater Interfaces, 2014. 6(22): p. 20378-84.
14. Gary W. Litman, J.P.R., Michael J. Shamblott, Robert N. Haire, Michele Hulst, William Roess, Ronda T. Litman, Kristin R. Hinds-Frey, Anna Zilch, and Chris T. Amemiyag, Phylogenetic Diversification of Immunoglobulin Genes and the Antibody Repertoire. Molecular Biology and Evolution, 1993. 10(1): p. 60-72.
15. Charles A Janeway, J., Paul Travers, Mark Walport, and Mark J Shlomchik., Immunobiology: The Immune System in Health and Disease. 5th edition. New York: Garland Science, 2001.
16. Dan Inbar, J.H., and David Givol, Localization of Antibody-Combining Sites within the Variable Portions of Heavy and Light Chains. Proceedings of the National Academy of Sciences of the U.S.A., 1972. 69(9): p. 2659-2662.
17. Poljak RJ, A.L., Avey HP, Chen BL, Phizackerley RP, Saul F., Three-dimensional structure of the Fab′ fragment of a human immunoglobulin at 2,8-A resolution. Proc. Nat. Acad. Sci. USA, 1973. 70(12): p. 3305-3310.
18. Morea, V., A.M. Lesk, and A. Tramontano, Antibody modeling: implications for engineering and design. Methods, 2000. 20(3): p. 267-79.
19. Richard O C., J.H., Linda Q. Judith R. G., David P., Stanley H., Near-Fatal Yew Berry Intoxication Treated With External Cardiac Pacing and DigoxinSpecific FAB Antibody Fragments Annals of Emergency Medicine 1990. 19(1): p. 38-43.
20. Bin Lu, J.X., Chunlin Lu, Changru Wu, and Yu Wei, Oriented Immobilization of Fab′ Fragments on Silica surface. Analytical Chemistry, 1995. 67(1): p. 83-87.
21. Kim, J.P., et al., Ultrasensitive carbon nanotube-based biosensors using antibody-binding fragments. Anal Biochem, 2008. 381(2): p. 193-8.
22. Elnathan, R., et al., Biorecognition layer engineering: overcoming screening limitations of nanowire-based FET devices. Nano Lett, 2012. 12(10): p. 5245-54.
23. Kristien Bonroy, F.F., Gunter Reekmans , Ellen Dewolf ,Randy De Palma, Gustaaf Borghs, Paul Declerck, Bruno Goddeeris, Comparison of random and oriented immobilisation of antibody fragments on mixed self-assembled monolayers. Journal of Immunological Methods, 2006. 312: p. 167-181.
24. Kumada, Y., et al., Efficient refolding and immobilization of PMMA-tag-fused single-chain Fv antibodies for sensitive immunological detection on a PMMA plate. J Immunol Methods, 2014. 411: p. 1-10.
25. Kumada, Y., et al., Efficient preparation and site-directed immobilization of VHH antibodies by genetic fusion of poly(methylmethacrylate)-binding peptide (PMMA-Tag). Biotechnol Prog, 2015. 31(6): p. 1563-70.
26. Plaut AG, T.T.J., Immunoglobulin M: pentameric Fcmu fragments released by trypsin at higher temperatures. Proc Natl Acad Sci U S A., 1970. 65(2): p. 318-322.
27. Maciej Adamczyk , J.C.G., Jiang Wu, Papain digestion of different mouse IgG subclasses as studied by electrospray mass spectrometry. Journal of Immunological Methods, 2000: p. 95-104.
28. M. MARIANI, M.C., L. TARDITI and E. SECCAMANI A NEW ENZYMATIC METHOD TO OBTAIN HIGH-YIELD F(ab)2, SUITABLE FOR CLINICAL USE FROM MOUSE IgGl Molecular Immunology, 1991. 28: p. 69-77.
29. Kinman, A.W.L. and R.R. Pompano, Optimization of Enzymatic Antibody Fragmentation for Yield, Efficiency, and Binding Affinity. Bioconjug Chem, 2019. 30(3): p. 800-807.
30. Ma, H. and R. O′Kennedy, Recombinant antibody fragment production. Methods, 2017. 116: p. 23-33.
31. Kind, M. and C. Wöll, Organic surfaces exposed by self-assembled organothiol monolayers: Preparation, characterization, and application. Progress in Surface Science, 2009. 84(7-8): p. 230-278.
32. Sagiv, J., Organized Monolayers by Adsorption, I. Formation and Structure of Oleophobic Mixed Monolayers on Solid Surfaces. Journal of the .4tnerican Chemical Society, 1980. 102(1).
33. GABRIELLA CAPECCHI, M.G.F., GIANMARIO MARTRA, SALVATORE COLUCCIA, MARIA FRANCESCA IOZZI and MAURIZIO Cossi Adsorption of CH3COOH on TiO2: IR and theoretical investigations. Res. Chem. Intermed, 2007. 33: p. 269-284.
34. Wang, G.M., W.C. Sandberg, and S.D. Kenny, Density functional study of a typical thiol tethered on a gold surface: ruptures under normal or parallel stretch. Nanotechnology, 2006. 17(19): p. 4819-4824.
35. Federica Rusmini, Z.Z., and Jan Feijen, Protein Immobilization Strategies for Protein Biochips. Biomacromolecules, 2007. 8: p. 1775-1789.
36. Chou, W.C., et al., Neutralized chimeric DNA probe for the improvement of GC-rich RNA detection specificity on the nanowire field-effect transistor. Sci Rep, 2019. 9(1): p. 11056.
37. Cheng, S., et al., Field Effect Transistor Biosensor Using Antigen Binding Fragment for Detecting Tumor Marker in Human Serum. Materials (Basel), 2014. 7(4): p. 2490-2500.
38. Cheng, S., et al., Label-free detection of tumor markers using field effect transistor (FET)-based biosensors for lung cancer diagnosis. Sensors and Actuators B: Chemical, 2015. 212: p. 329-334.
39. Kim, K., et al., Silicon nanowire biosensors for detection of cardiac troponin I (cTnI) with high sensitivity. Biosens Bioelectron, 2016. 77: p. 695-701.
40. Gao, N., et al., General strategy for biodetection in high ionic strength solutions using transistor-based nanoelectronic sensors. Nano Lett, 2015. 15(3): p. 2143-8.
41. Filipiak, M.S., et al., Highly sensitive, selective and label-free protein detection in physiological solutions using carbon nanotube transistors with nanobody receptors. Sensors and Actuators B: Chemical, 2018. 255: p. 1507-1516.
42. Andoy, N.M., et al., Graphene‐Based Electronic Immunosensor with Femtomolar Detection Limit in Whole Serum. Advanced Materials Technologies, 2018. 3(12).
43. Gutierrez-Sanz, O., et al., Direct, Label-Free, and Rapid Transistor-Based Immunodetection in Whole Serum. ACS Sens, 2017. 2(9): p. 1278-1286.
44. Hideshima, S., et al., Label-free detection of allergens in food via surfactant-induced signal amplification using a field effect transistor-based biosensor. Sensors and Actuators B: Chemical, 2018. 254: p. 1011-1016.
45. Yoshida, Y., et al., Rabbit antibody detection with RNA aptamers. Anal Biochem, 2008. 375(2): p. 217-22.
46. Gao, N., et al., Specific detection of biomolecules in physiological solutions using graphene transistor biosensors. Proc Natl Acad Sci U S A, 2016. 113(51): p. 14633-14638.
47. White, S.P., et al., Rapid, Selective, Label-Free Aptameric Capture and Detection of Ricin in Potable Liquids Using a Printed Floating Gate Transistor. ACS Sensors, 2016. 1(10): p. 1213-1216.
48. Tsai, W.-C. and I.-C. Li, SPR-based immunosensor for determining staphylococcal enterotoxin A. Sensors and Actuators B: Chemical, 2009. 136(1): p. 8-12.
49. Luna-Moreno, D., et al., Early Detection of the Fungal Banana Black Sigatoka Pathogen Pseudocercospora fijiensis by an SPR Immunosensor Method. Sensors (Basel), 2019. 19(3).
50. Ma, S., et al., Direct label-free protein detection in high ionic strength solution and human plasma using dual-gate nanoribbon-based ion-sensitive field-effect transistor biosensor. Biosens Bioelectron, 2018. 117: p. 276-282.
51. Guo-Jun Zhang, G.Z., Jay Huiyi Chua, Ru-Ern Chee, Ee Hua Wong, Ajay Agarwal, Kavitha D. Buddharaju, Navab Singh, Zhiqiang Gao, and N. Balasubramanian, DNA Sensing by Silicon Nanowire: Charge Layer Distance Dependence. NANO LETTERS, 2008. 8(4): p. 1066-1070.
52. De Vico, L., et al., Quantifying signal changes in nano-wire based biosensors. Nanoscale, 2011. 3(2): p. 706-17.
53. Kemeng Wang, G.W.a.D.L., CD19: a biomarker for B cell development, lymphoma diagnosis and therapy. Experimental Hematology & Oncology, 2012. 1(1).
54. Fumiaki N. Ishikawa, H.-K.C., Marco Curreli, Hsiang-I Liao, C. Anders Olson, Po-Chiang Chen, Rui Zhang, Richard W. Roberts, Ren Sun, Richard J. Cote, Mark E. Thompson, and Chongwu Zhou, Label-Free, Electrical Detection of the SARS Virus N-Protein with Nanowire Biosensors Utilizing Antibody Mimics as Capture Probes. ACS Nano, 2009. 3(5): p. 1219-1224.
55. Fumiaki N. Ishikawa, M.C., Hsiao-Kang Chang, Po-Chiang Chen, Rui Zhang, Richard J. Cote, Mark E. Thompson, and Chongwu Zhou, A Calibration Method for Nanowire Biosensors to Suppress Device-to-Device Variation. ACS Nano, 2009. 3(12): p. 3969-3976.
56. De Vico, L., et al., Predicting and rationalizing the effect of surface charge distribution and orientation on nano-wire based FET bio-sensors. Nanoscale, 2011. 3(9): p. 3635-40.
57. Fenton, D.W.P.a.B.H., pH stability and activity curves of pepsin with special reference to their clinical importance. BMJ Journals, 1965. 6: p. 506-508.
58. Johnston, N., et al., Activity/stability of human pepsin: implications for reflux attributed laryngeal disease. Laryngoscope, 2007. 117(6): p. 1036-9. |