Energy saving and carbon reduction are a mission of the generation nowadays and a responsibility of human beings. This study evaluated the benefit of power reduction via lighting improvement for a junior high school, and the results reveal 66.07% power saving which equals the saving of NTD 709,216 electricity bill and reduction of 108.5 tons CO2e emission per year after the implementation. Power saving is achieved via choo-sing energy-efficient LED lighting and modification of the wiring path. Specifically, the current lamps are replaced with suitable 1.2m ,14W, T8/T5 LED lamps and 0.6m, 7W T8 LED lamps. Prior to this eco-project, the school faced the shortage of funding for energy-efficient lighting replacement program. In order to overcome the budget shortage challenges, they collaborated with Energy /Engineering Service Company (ESCO), working together under a project called Energy Saving Performance Contracts (ESPC). ESPC lasts 7 years; however, its return on investment (ROI) is 4.37 years according to the data collected. The verification of Energy Savings Performance for the study is via the option A of International Performance Measurement and Verification Protocol (IPMVP) in which the saving is measured by the key performance of critical parameters, and the lighting is 1,600 hours per year. We installed digital electricity meters in three classes, and monitored daily power consumption for a year in order to verify whether the 1,600 hours criteria of a year is rational. The results indicated that the power consumption is over 1,600 hours in two of the three classes and the other one is 1,320 hours. Although the power consumptions of two classes are over 1,600 hours in a year, the rational criteria of power consumption should be evaluated for the following cases due to the trend of power saving and carbon reduction. Next, we replaced the lighting with 1.2m, 10W T8 and 0.6m, 5W T8 energy-efficient LED lamps, and kept track whether the overall saving achieved over 75%. The results revealed that the total energy saving of three classes is 70% instead of 75% target, since the proportion of T5 LED lighting is higher (58%) than T8 LED lighting (42%). The overall energy saving is highly related to the proportion between T5 and T8 LED which should be listed as an evaluation item before leading an energy saving project. |
參考文獻 |
參考文獻
Asif, M., Ahmed, W., Alazazmeh A. (2022) Energy performance assessment of a post-retrofit office building using measurement and verification protocol: A case study from KSA. Energy Reports, 1366-1379.
Castilla, N., Llinares, C., Bisegna, F., Blanca-Giménez, V. (2018) Emotional evaluation of lighting in university classrooms: A preliminary study. Frontiers of Architectural Research, 600-609.
Cowan, J. (2002) International performance measurement and verification protocol. International Performance Measurement & Verification Protocol, 1.
Ding, Y., He, S., Teixeira da Silva, J. A., Li G., Tanaka M. (2010) Effects of a new light source (cold cathode fluorescent lamps) on the growth of tree peony plantlets in vitro. Scientia Horticulturae, 167-169.
Fang, W. S., Miller, S. M., Yeh C.C. (2012) The effect of ESCOs on energy use. Energy Policy, 558-568.
Garbuzova-Schlifter, M., Madlener R. (2016) AHP-based risk analysis of energy performance contracting projects in Russia. Energy Policy, 559-581.
Polzin, F., von Flotow, P., Nolden C. (2016) What encourages local authorities to engage with energy performance contracting for retrofitting? Evidence from German municipalities. Energy Policy, 317-330.
Patari, S., Sinkkonen K. (2014) Energy Service Companies and Energy Performance Contracting: is there a need to renew the business model? Insights from a Delphi study. Journal of Cleaner Production, 264-271.
Principi, P., Roberto, F., Carbonari, A., Lemma, M. (2016) Evaluation of energy conservation opportunities through Energy Performance Contracting: A case study in Italy. Energy and Buildings, 886-899.
Ryckaert, W. R., Smet, K. A. G., Roelandts I. A. A., Van Gils, M.,Hanselaer, P. (2012) Linear LED tubes versus fluorescent lamps: An evaluation. Energy and Buildings, 429-436.
Wang, Z., Li, G., He, S., Teixeira da Silva, J. A. Tanaka, M. (2011) Effect of cold cathode fluorescent lamps on growth of Gerbera jamesonii plantlets in vitro. Scientia Horticulturae, 482-484.
工業技術研究院 (2018) 室內高效率照明設計指引手冊.
方育斌 (2004) LCD背光模組之光學最佳化設計 工程科學系碩博士班,台南市: 國立成功大學.
王長慶 (2022) 以校園氣候變遷課程提升國小高年級學生自我效能與環境素養之評量研究 科學教育與應用學系環境教育及管理碩士班,台中市: 國立臺中教育大學.
王相賀 (2017) 應用田口實驗法優化LED燈管及高效率燈具設計之研究 電機工程系,台北市: 國立臺灣科技大學.
江俊德 (2015) 具有高功率因數與頻閃補償之LED驅動器研製 電機工程系,桃園市: 中原大學.
吳佳薇 (2012) 較佳垂直均勻配光分佈之燈具設計與其應用研究 電機工程系, 台北市: 國立臺灣科技大學.
林靖傑 (2010) T8-CCFL照明光源之研製 電機工程研究所, 雲林縣: 國立虎尾科技大學.
洪國豪 (2006) 學校教室照明燈具設計之研究 建築與都市設計研究所, 台北市: 國立臺北科技大學.
臺灣氣候變遷科學團隊 (2021) IPCC 氣候變遷第六次評估報告之科學重點摘錄與臺灣氣候變遷評析更新報告.
徐愷宏 (2011) 教室更換T5高效率燈具使用後評估與願付價值之研究-以彰化縣中小學為例 建築與室內設計系碩士班, 雲林縣: 國立雲林科技大學.
張金榮 (2020) LED照明標準因應小組暨LED照明相關國家標準說明會講義資料 財團法人臺灣大電力研究試驗中心.
教育部 (2013) 學校照明節能改善參考手冊
郭子文 (2010) 加速顧客採用新產品的經營模式-以LED燈管為例 企業管理學系碩士在職專班, 桃園縣: 國立中央大學.
陳保生 (2010) LED燈管及反射罩之光學設計研究 電機工程系, 台北市: 國立臺灣科技大學.
陳振華 (2011) 集合住宅公共空間換置T5照明系統之節能效益研究 土木與防災研究所, 台北市: 國立臺北科技大學.
陳瑞鈴,周鼎金,黃竣道,賀大行,林成翰 (2007) 辦公室照明設計節能參考手冊之研究 內政部建築研究所協同研究報告.
陳靜仁 (2011) 晝光照明節能利用效益之評估-以CCFL與T5為例 建築學系碩博士班, 台南市: 國立成功大學.
曾鵬引,黃天昶 (2021) 能源技術服務產業發展現況 財團法人台灣綠色生產力基金會-ESCO會訊第66期 第 7 ~ 12頁.
楊國盛 (2015) 大專院校照明與空調績效測量驗證與節能效益研究 建築系建築與都市設計碩士班(碩士在職專班). 台北市: 國立臺北科技大學.
經濟部能源局 (2020) 室內照明燈具節能標章能源效率基準與標示方法修正規定.
經濟部能源局 (2021) 設備器具能源效率管理 經濟部能源局網站.
經濟部標準檢驗局 (2012) CNS12112_室內工作場所照明_101版.
綠基會 (2007) 照明節能改善之節能績效量測與驗證方法 綠基會.
趙宏耀 (2006) 如何驗證節約能源成效-IPMVP簡介 綠基會通訊.
劉旻忠 (2020) 產業照明系統節能技術手冊-工研院.
蔡宏達 (2022) 淨零能源建築之照明節能推動策略 財團法人台灣產業服務基金會.
鍾兆文 ( 2015) 中小企業冰水主機實測及COP評估於IPMVP為導向之節能控制邏輯設計-以網咖實證 通訊資訊數位學習碩士在職專班, 嘉義縣: 國立中正大學.