English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41255589      線上人數 : 173
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/2784


    題名: 膝關節局部表面重建研究;A research on surface reconstruction for partial knee surface repairing
    作者: 蘇文;Vincent So
    貢獻者: 機械工程研究所
    關鍵詞: 徑向基底函數神經網路;移動式最小平方法;膝關節表面重建;radial basis function neural network;moving least squares;knee joint;joint resurfacing reconstruction
    日期: 2008-07-09
    上傳時間: 2009-09-21 11:55:51 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 在膝關節表面重建手術中,由於所裝配的植入物表面直接與病患的半月板及關節軟骨接觸摩擦,若此一表面與膝關節未受損處之表面無法正確吻合,則可能導致病患膝關節的損傷及加速植入物的損壞。為了避免上述問題,本研究希望藉由膝關節上受損部位周圍之軟骨表面資料,重建受損部位應有的平滑表面,以做為植入物設計的參考。 在表面重建的方法上,本研究提出以移動式最小平方法和徑向基底函數神經網路作為修補膝關節表面缺損的方法。前者是在常見的最小平方法中加入權重值做調整,以修正嵌合的誤差;後者則是利用所建構之徑向基底函數,以函數逼近的方式找到輸入與輸出間的關係,藉此建立膝關節表面的數學模型。 由實驗結果可以發現徑向基底函數神經網路較適合應用於修補膝關節表面上的缺損,在膝關節較易受損的內髁部位,即使受損部份佔重建區域達49.7%,其修補的最大誤差僅為0.171㎜、平均誤差亦僅為0.052㎜。故日後在設計用於修補膝關節表面微小受損的植入物時,可考慮採用以徑向基底函數神經網路計算所得之曲面作為植入物設計的依據。 In resurfacing reconstruction of the knee joint, the surface of the implant will contact the plateau and joint cartilage dynamically. If the implant surface does not fit well with the joint surface, it could lead to the damage of both the knee joint and the implant. This research aims to use the surrounding cartilage surface of the joint defect to reconstruct original surface, which will be used for the design of the resurfacing implant. As for the methods of surface reconstruction, moving least squares method and radial basis function neural network are proposed for restoration of the normal surface of the joint defect. The former uses a weighting method to compensate the errors of fitting; while the latter uses radial basis functions to find the relationship of input and output in order to modeling the surface. Both of the methods are applied to reconstruct various curved surfaces. The experimental results show that radial basis function neural network is better to restore the damaged knee joint surface. Also, at the easily damaged condyle part of the knee joint, the maximum approximation error is 0.171㎜ and the average approximation error is only 0.052㎜ even if the defect part of the reconstruction area reaches 49.7%. Based on the results, the radial basis function neural network is recommended to be used to generate resurfacing implants for the reconstruction of the knee joint defect.
    顯示於類別:[機械工程研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明