English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41245663      線上人數 : 109
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/27929


    題名: STEPS TOWARD DETERMINATION OF THE SIZE AND STRUCTURE OF THE BROAD-LINE REGION IN ACTIVE GALACTIC NUCLEI .5. VARIABILITY OF THE ULTRAVIOLET CONTINUUM AND EMISSION-LINES OF NGC-3783
    作者: REICHERT,GA;RODRIGUEZPASCUAL,PM;ALLOIN,D;CLAVEL,J;CRENSHAW,DM;KRISS,GA;KROLIK,JH;MALKAN,MA;NETZER,H;PETERSON,BM;WAMSTEKER,W;ALTAMORE,A;ALTIERI,B;ANDERSON,KS;BLACKWELL,JH;BOISSON,C;BROSCH,N;CARONE,TE;DIETRICH,M;ENGLAND
    貢獻者: 天文研究所
    關鍵詞: SEYFERT-GALAXY NGC-5548;OPTICAL WAVELENGTHS;EXPLORER IUE;SWP CAMERA;FE-II;NGC-3783;QUASARS;SPECTROSCOPY;ACCURACY;GEOMETRY
    日期: 1994
    上傳時間: 2010-06-29 19:36:28 (UTC+8)
    出版者: 中央大學
    摘要: We report on the result of intensive ultraviolet spectral monitoring of the Seyfert 1 galaxy NGC 3783. The nucleus of NGC 3783 was observed with the International Ultraviolet Explorer satellite on a regular basis for a total of 7 months, once every 4 days for the first 172 days and once every other day for the final 50 days. Significant variability was observed in both continuum and emission-line fluxes. The light curves for the continuum fluxes exhibited two well-defined local minima or ''dips,'' the first lasting less than or similar to 20 days and the second less than or similar to 4 days, with additional episodes of relatively rapid flickering of approximately the same amplitude. As in the case of NGC 5548 (the only other Seyfert galaxy that has been the subject of such an intensive, sustained monitoring effort), the largest continuum variations were seen at the shortest wavelengths, so that the continuum became ''harder'' when brighter. The variations in the continuum occurred simultaneously at all wavelengths (Delta t <2 days). Generally, the amplitude of variability of the emission lines was lower than (or comparable to) that of the continuum. Apart from Mg II (which varied little) and N V (which is relatively weak and badly blended with Ly alpha), the light curves of the emission lines are very similar to the continuum light curves, in each case with a small systematic delay or ''lag'' As for NGC 5548, the highest ionization lines seem to respond with shorter lags than the lower ionization lines. The lags found for NGC 3783 are considerably shorter than those obtained for NGC 5548, with values of(formally) similar to 0 days for He II + O III], and similar to 4 days for Ly alpha and C IV. The data further suggest lags of similar to 4 days for Si IV + O IV] and 8-30 days for Si III] + C III]. Mg II lagged the 1460 Angstrom continuum by similar to 9 days, although this result depends on the method of measuring the line flux and may in fact be due to variability of the underlying Fe II lines. Correlation analysis further shows that the power density spectrum contains substantial unresolved power over timescales of less than or similar to 2 days, and that the character of the continuum variability may change with time.
    關聯: ASTROPHYSICAL JOURNAL
    顯示於類別:[天文研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML601檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明