English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41254353      線上人數 : 265
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/3203


    題名: 髕股骨人工關節之動靜態分析與測試;Dynamic and Static Analyses and Experimental Evaluation of Patellofemoral Prosthesis
    作者: 駱主安;Chu-An Luo
    貢獻者: 機械工程研究所
    關鍵詞: 關節炎;客製化;髕股骨植入物;動態模擬;有限元素分析;custom-made;dynamic simulation;finite element analysis;patellofemoral prosthesis;arthritis
    日期: 2009-06-27
    上傳時間: 2009-09-21 12:09:07 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 隨著科技進步與醫學發達,人類平均壽命逐年增加,同時也伴隨各種因老化造成的疾病;退化性關節炎即跟年齡老化有直接關係,主要病變的地方是兩骨頭的關節接觸面。目前單一退化性髕股骨關節炎,臨床治療方式有:(1)全人工膝關節置換;(2)表面置換型人工髕股骨關節。其可減少病患因關節炎產生之不適,增進髕股骨間滑動正常。表面置換型人工髕股骨關節好處在於微小骨切除量,未來關節炎若持續惡化可進行全關節置換。 本研究結合醫學影像重建技術,撰寫客製化關節曲面設計程式,自動產生與病患骨關節曲面完整貼合之植入物模型,並修改手術器械設計,有效縮減手術傷口,提高其可行性與便利性。此外,由動態模擬實際建構髕股骨關節運動分析平台,將得到膝關節運動時,植入物受力參數輸入有限元素分析模型進行分析,探討特定角度植入物受力情形及是否發生沉陷現象,以及植入物之楯的型式對本身應力分布與穩定度的影響,藉以改進客製化人工髕股骨關節之設計。 Recently, human life became more and more elder because of the advancement of scientific technology and the development of medicine. But it also accompanies the disease caused by aging. Like the osteoarthritis, which the most obvious example is. There are two kinds of treatment for isolated patellofemoral osteoarthritis. One is total knee arthroplasty, the other is surface replacement prosthesis for patellofemoral joint. Both of them can help the patients with the osteoarthritis to get rid of the uncomfortable experience, and promoting to slide normally between patella and femur. The osteotomy can resect less quality of the bone is the advantage of surface replacement prosthesis for patellofemoral joint. So it will proceed the total knee replacement even if the osteoarthritis become worse in future. In order to produce the model of patellofemoral prosthesis that contact well with the surface of the bone from the patient automatically, this research combined the reconstruction of technology with medical image, and composing the program for the custom-made implant. Furthermore, it modified the design of the surgical instruments for reducing the wound from operation and raising the feasibility and convenience of the operating method. In addition, obtaining the contact force between patellar component and patellofemoral implant in knee motion from the dynamic simulation, which we constructed so as to find out the knee motion after the arthroplasty. Finally, using finite element analysis to get the stress distribution and stability of the implant, and bring up some principle points while designing.
    顯示於類別:[機械工程研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明