中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/49868
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 40249682      在线人数 : 275
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/49868


    题名: Effects of implant threads on the contact area and stress distribution of marginal bone
    作者: Lee,CC;Lin,SC;Kang,MJ;Wu,SW;Fu,PY
    贡献者: 生物醫學工程研究所
    关键词: FINITE-ELEMENT;DENTAL IMPLANTS;ORTHODONTIC ANCHORAGE;CORTICAL BONE;DIAMETERS;DESIGN
    日期: 2010
    上传时间: 2012-03-27 16:25:08 (UTC+8)
    出版者: 國立中央大學
    摘要: Background/purpose: Stable osseointegration between implant threads and the surrounding marginal bone provides the mechanical base of an implant for daily chewing activity. The contact area of implant-bone interfaces and the concentrated stresses on the marginal bones are principal concerns of implant designers. The purpose of this study was to investigate the effects of thread shape and taper on the initial stability of the implant-bone structure. Materials and methods: The thread design was parameterized by shape and taper. Thread shapes included symmetrical, square, and buttressed. Thread tapers were divided into cylindrical and conical profiles. Nine variations of the thread design were developed to numerically evaluate their geometric and mechanical effects on the marginal bone. Results: Among the three thread shapes with the same pitch, the contact area of the square thread was the highest. Among all implant models, it was found that the site with the greatest stress in the surrounding jaw bone was consistently concentrated at the root radii of the first thread. The maximal stress of the square thread was the least. For the same thread shape and taper, a finer pitch resulted in a remarkable increase in the contact area and a decrease in the peak stress. The contact areas and peak stresses of the conical and cylindrical implants were nearly equal. Conclusion: Taking wall thickness and stress concentrations into consideration, the square thread with a 0.60-mm pitch possessed the optimal contact area and stress values compared to the others.
    關聯: JOURNAL OF DENTAL SCIENCES
    显示于类别:[生物醫學工程研究所 ] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML621检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明