中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/51068
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 40249679      在线人数 : 273
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/51068


    题名: Detrended fluctuation analysis predicts successful defibrillation for out-of-hospital ventricular fibrillation cardiac arrest
    作者: Lin,LY;Lo,MT;Ko,PCI;Lin,C;Chiang,WC;Liu,YB;Hu,K;Lin,JL;Chen,WJ;Ma,MHM
    贡献者: 系統生物與生物資訊研究所
    关键词: WAVE-FORM ANALYSIS;CARDIOPULMONARY-RESUSCITATION;TIME-SERIES;VARIABILITY;AMPLITUDE;DOGS
    日期: 2010
    上传时间: 2012-03-27 18:20:27 (UTC+8)
    出版者: 國立中央大學
    摘要: Aims: Repeated failed shocks for ventricular fibrillation (VF) in out-of-hospital cardiac arrest (OOHCA) can Worsen the Outcome. It is very important to rapidly distinguish between early and late VF. We hypothesised that VF waveform analysis based on detrended fluctuation analysis (DFA) can help predict successful defibrillation. Methods: Electrocardiogram (ECG) recordings of VF signals from automated external defibrillators (AEDs) were obtained for subjects with OOHCA in Taipei city. To examine the time effect on DFA, we also analysed VF signals in subjects who experienced Sudden cardiac death during Holter study from PhysioNet, a publicly accessible database. Waveform Parameters including root-mean-squared (RMS) amplitude, mean amplitude, amplitude spectrum analysis (AMSA), frequency analysis as well as fractal measurements including scaling exponent (SE) and DFA were calculated. A defibrillation was regarded as Successful when VF was converted to an organised rhythm within 5 s after each defibrillation. Results: A total of 155 OOHCA subjects (37 successful and 118 unsuccessful defibrillations) with VF were included for analysis. Among the VF waveform parameters, only AMSA (7.61 +/- 3.30 vs. 6.30 +/- 13.13, P=0.028) and DFA alpha 2 (0.38 +/- 0.24 vs. 0.49 +/- 0.24, P=0.013) showed significant difference between subjects With Successful and unsuccessful defibrillation. The area under the Curves (AUCs) for AMSA and DFA alpha 2 was 0.63 (95% confidence interval (CI) = 0.52-0.73) and 0.65 (95% CI = 0.54-0.75), respectively. Among the waveform parameters, only DFA alpha 2, SE and dominant frequency showed significant time effect. Conclusions: The VF waveform analysis based on DFA could help predict first-shock defibrillation Success in patients with OOHCA. The clinical utility of the approach deserves further investigation. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
    關聯: RESUSCITATION
    显示于类别:[系統生物與生物資訊研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML947检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明