中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/61460
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 41269584      在线人数 : 198
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/61460


    题名: 波長移相雙繞射干涉儀之研究;Study of wavelength phase-shifted double diffraction interferometer
    作者: 江耿安;Jiang,Geng-An
    贡献者: 光機電工程研究所
    关键词: 光學量測;波長移相;光柵繞射;雷射二極體;位移量測;相位擷取;Optical measurement;Wavelength phase-shift;Grating diffraction;Laser Diode;Displacement measurement system;Phase analysis
    日期: 2013-08-07
    上传时间: 2013-10-08 15:12:48 (UTC+8)
    出版者: 國立中央大學
    摘要: 本文提出一波長移相雙繞射干涉儀,此位移量測系統分為兩部分,在光學架構部分,由於光柵的繞射效應可以將光柵位移的訊息轉換成光的相位訊息,利用鏡子反射繞射光,使含有光柵位移相位的繞射光再一次反射回光柵產生繞射,因為通過了兩次光柵,產生兩次繞射提高了相位對應光柵位移的靈敏度,並且在反射鏡部分設計一個固定的光程差,使波長的變化可以轉換成相位變化。
    在相位解析系統中,以雷射二極體搭配訊號產生器調制波長,並調整調制訊號所需的振幅,使量測訊號在高點與低點因為波長的不同有90度的相位差,此相位差使得量測訊號在訊號高點與低點位置有一個正餘弦關係存在,將量測訊號送入開發出的相位解析程式,即可求出相位值,最後推算出光柵位移量,免去了使用昂貴的鎖相放大器進行相位解析,降低了系統的成本,使得本系統的利用價值大大提高。實驗結果顯示出此系統具有良好的穩定性及重復性,在考慮高頻雜訊的情況下,系統的解析度達1.5 nm,靈敏度為g/d=0.72 ?/nm。優於市售的位移感測器,本系統可應用於精密位移量測、精密位移平台的震動量測、微動定位系統。
    In this paper, we present a wavelength phase-shifted double diffraction interferometer for measuring displacement. This displacement measurement system is divided into two sections, in the optical configuration section, according to the optical phase variation resulting from the moving grating, we design a light path, it can be used to increase the sensitivity of the phase change, and using the wavelength-modulated laser beam which passing through an unequal-path-length optical configuration by two mirrors, it can change the system phase.
    On the other hand, using the wavelength-modulated laser produce two signals that phase difference of 90 degrees can be sent into a phase analyze system. The phase analysis system obtained grating displacement by the relationship between the sine position light intensity and cosine position light intensity, eliminating the need for a lock-in amplifier, which makes utilization value of the system greatly, the experimental results show that the system has high stability and repeatability, if only high frequency noises are considered, the measurement resolution of our system is about 1.5 nm, the sensitivity is 0.72 ?/nm and the measureable speed is 5.5 um/s. The system can be a useful sensor to monitor the displacement and vibration of the precision motorized stage using in wide scientific research.
    显示于类别:[光機電工程研究所 ] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML1035检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明