中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/66738
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 41272391      在线人数 : 1150
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/66738


    题名: 多層多跨具自復位梁柱接頭隅撐構架之耐震性能研究;Seismic performance of multi-bay-multi-story knee braced frames with dual self-centering mechanisms
    作者: 涂崢嶸;Tu,Cheng-Jung
    贡献者: 土木工程學系
    关键词: 多跨多層構架;雙重自復位機制;能量消散;耐震效能;Multi-bay-multi-story frame;Dual self-centering mechanisms;Energy dissipation;Seismic performance
    日期: 2015-01-26
    上传时间: 2015-03-16 15:08:07 (UTC+8)
    出版者: 國立中央大學
    摘要: 隅撐抗彎構架為近年來發展之新型結構系統,其可改善抗彎構架側向勁度不足之問題,亦可有較同心斜撐構架良好之韌性,然當隅撐構架受側向力作用,受壓側之隅撐會產生挫屈行為,導致構架強度驟降,故近年來發展了雙重自復位機制以改善此問題,而雙重自復位機制由具自復位梁柱接頭與自復位隅撐組成。由於實際工程應用上,結構係屬多層多跨形式,故本研究針對具雙重自復位多層多跨構架進行反覆載重試驗,以界定其耐震性能。研究結果顯示,雙重自復位構架可較同尺度之抗彎構架提升 1.66~1.69 倍之構架強度,其勁度亦可提升約 2.91 倍。研究中亦發現,自復位梁柱接頭配置角鋼摩擦消能機制可較無配置者提升約2.38倍之能量消散。另構架在預力系統保持彈性階段時,皆具有良好之自復位能力,可有效降低結構之殘餘變形,且當雙重自復位構架之上層與下層梁柱接頭之結合彎矩比例為1:1.5時,在相同頂層位移下,較上層與下層梁柱接頭之結合彎矩比例為1:1時,提供構架較佳變形能力。研究結果證實,雙重自復位機制可提供構架良好之變形能力與強度,並可有效延後梁構件降伏時機,達到提升結構耐震性能之目的。;Knee braced moment resisting frame (KBRF) has been developed in recent years. The KBRF system possesses higher stiffness than the moment resisting frame (MRF) and larger ductility than the concentrically braced resisting frame (CBRF), thus is a suitable structural form for earthquake-resistant purposes. However, when the KBRF is subject to heavy cyclic load, the knee braces that contribute to the structural strength will reach the buckling stage, causing major loss in structural performance. In order to improve the structural performance of the KBRF system, a modified design using dual self-centering mechanisms in the knee brace members and the beam-to-column connections was proposed in this study. A set of copper plates were used in the beam-to-column connections to dissipate energy through friction mechanism. A series of cyclic loading tests were conducted on the multi-bay-multi-story KBRFs to evaluate their performance.
    It was found from the tests that the strength, stiffness and energy dissipation capacity of KBRF with dual self-centering mechanisms was higher than the MRF with equivalent dimensions. Test results also showed that the major structural members, including beams and columns, remained intact when the structural was subject to large drift, which justified the effectiveness of the proposed method. Further comparisons on the structural performance suggested that the ratio of joint decompression strength between lower and upper stories be approximately 1.5 so that higher structural performance could be achieved.
    显示于类别:[土木工程研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML484检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明