中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/6795
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 80990/80990 (100%)
Visitors : 41250869      Online Users : 610
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/6795


    Title: 利用三角測量法量測人體脈搏;Using triangulation finds human's pulse
    Authors: 陳俊吉;Jun-Gi Chen
    Contributors: 光電科學研究所
    Keywords: 三角量測法;疊紋;moire;triangulation
    Date: 2005-06-30
    Issue Date: 2009-09-22 10:28:41 (UTC+8)
    Publisher: 國立中央大學圖書館
    Abstract: 摘要 本論文利用三角測量法量測人體脈搏中,首先我們先運用MOIRE(疊紋)定位脈搏位置,利用疊紋法可較準確定位出脈搏位置,再利用雷射打在脈搏上在使用CMOS(互補性氧化金屬半導體)影像擷取系統,擷取影像,再利用MATLAB軟體計算雷射質心變化,再利用系統中三角關係求出脈搏變化大小,再運用FFT(Fast Fourier Transfer 快速傅立葉轉換)求出脈搏波的頻率,此一系統結構簡單且精確(精確度可達10um)。 ABSTRACT There are a lot of measurement methods or equipments for measuring the pulse of human being, including palpation, stethoscope, sphygmomanometer, electrocardiogram (ECG), oximeter, pressure transducer, optical interferometer, Doppler-based instrumentation, and this optical triangulation pulse measurement system we proposed here. Arterial pulsation waveform has been considered as fundamental indicators in the diagnosis of cardiovascular disease and guide therapeutic decision in complex clinical situations. Abnormality of shapes and frequencies of palpation are symbols of certain cardiovascular disorders, thus how to pick up arterial pulse waveforms without distortion has become an important issue in biomedical signal processing. On the other hand, pulse diagnosis is the one of four kind diagnosis methods to determine the physiological condition of patients in Traditional Chinese Medicine (TCM). In clinic, most popular methods applied to measure pulse behavior include stethoscope, sphygmomanometer, and Doppler-based instrumentation. In TCM, most studies of pulse diagnosis machine use other devices to record pulse changes. A set of three pressure transducers to sense three location pulses has been proposed. Lu and Wang analyzed the harmonics from the frequency spectrum of pulse waves and related some illness condition to certain harmonics. The devices used in these studies could either interfere in the measurement because contacting or cost more as having additional sensors for multiple points probing. No touch pulse measurement with optical interferometer was proposed by Hong et.al, it can estimate skin vibration velocity. Echo-metric techniques which would make use of time-of-flight measurements of an energy pulse reflected from points on the object are not practical at short rangers due to very short time intervals that have to be measured. An optical non-contacting technology, which based on optical triangulation, is proposed in this study. Optical triangulation is well known in thickness and contour measurement, and applied to many industrial fields. This study will conduct the design of the pulse measurement system and verify the pulse measurement accuracy, then using this pulse measurement system to build a complete data base by measuring the patients. Moire’ will be used to locate the top of the pulse, then the vibration and frequency of the pulse will be record with this laser pulse measurement.
    Appears in Collections:[Graduate Institute of Optics and Photonics] Electronic Thesis & Dissertation

    Files in This Item:

    File SizeFormat


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明