中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/72294
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 78852/78852 (100%)
造訪人次 : 38483366      線上人數 : 113
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/72294


    題名: 單手臂心電圖之脈波傳遞速度量測系統;A Single-arm Pulse-wave Velocity Measurement System
    作者: 陳亮宏;Chen,Liang-Hung
    貢獻者: 電機工程學系
    關鍵詞: 收縮壓;脈波傳遞速度;單手臂心電圖;systolic blood pressure;PWV;single arm ECG
    日期: 2016-08-29
    上傳時間: 2016-10-13 14:37:36 (UTC+8)
    出版者: 國立中央大學
    摘要: 目前一般市售電子血壓計皆使用振盪法,使用壓脈帶阻斷血管血流,以壓力感測器偵測壓脈帶內微小之壓力變化,為提升舒適度與監測血壓變化趨勢,近幾年有學者使用脈波傳遞速度原理開發連續非加壓式的血壓量測系統。這些系統使用雙手量測ECG的Lead I心電訊號,配合指夾式PPG,測量心電圖R波與PPG特徵點之間的時間差,推估血管收縮壓。然而,這種雙手ECG與指夾式PPG的量測方法,會造成雙手不便與指尖長時間壓迫,而感到不方便與不舒服。
    因此,我們提出單手臂心電圖取代傳統Lead I 心電圖,手臂反射式光體積變化(Photoplethysmogram , PPG)取代手指穿透式PPG。我們先在9位健康受測者(25.1±4.3321歲)建立脈波傳遞速率之血壓模型,然後以10 位正常人( 41.6±14.2歲)與12為高血壓患者(52.75±10.1歲) 作為驗證,估測血壓誤差結果在正常人與病人分別為1.71±1.34%與5.71±4.54%。本研究已經可以達到接近實際使用的程度,未來期待本論文之研究方法能改良後套用在穿戴式裝置上,使血壓量測更便利與更準確。
    ;Most of the current commercial electronic sphygmomanometers use the oscillometric method. The oscillometic method occludes blood flow by using the inflatable cuff, and using a piezoelectric pressure sensor to detected the pulsatility in arterial wall. To improve the user’s comfort and monitor the short term trend of blood pressure, in recent years, some researchers propose a novel cuffless blood pressure measurement system by using the pulse wave velocity (PWV) technique. These measurement system measure Lead I ECG from both hands and the fingertip PPG, and then calculate the Systolic blood pressure (SBP) by compute the time delay between the electrocardiogram (ECG) R peak and the Photo-plethysmography (PPG) characteristics. However, the measurement of ECG from both hands is inconvenient and the clip of fingertip PPG is uncomfortable after long-time use.
    Therefore, in this study, we proposed a novel system by measuring single-arm ECG and wrist reflectance-based PPG. We first create a SBP estimation model from nine health subjects (mean ages = 25.1±4.3321 years-old), and the apply the model on ten normal subjects (mean ages = 41.6±14.2 years-old) and twelve hypertension patients (mean ages = 52.75±10.1 years-old). The estimated error in the ten normal subjects and the twelve hypertension patients are 1.71±1.34% and 5.71±4.54%, respectively, which demonstrate the feasibility of the proposed system. Future work will apply our method on wearable devices in order to provide a convenient and accurate way for long-term SBP monitoring.
    顯示於類別:[電機工程研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML523檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明