中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/75089
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 41252228      線上人數 : 602
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/75089


    題名: 裝置於微流體晶片上的環狀超聲波共振壓電片套用於微流體技術與質譜儀分析之間的介面應用;Piezo-Ring-on-Chip Microfluidics Device for Mass Spectrometry Interfacing
    作者: 雷以兆;Lei, I-Chao
    貢獻者: 機械工程學系
    關鍵詞: 微流體;質譜儀;介面;microfluidic;MALDI - MS;interfacing
    日期: 2017-08-16
    上傳時間: 2017-10-27 16:19:57 (UTC+8)
    出版者: 國立中央大學
    摘要: 作為一個用於微流體技術與質譜儀分析的介面,該技術必須要能夠適用於現存已有的微流體晶片,使用外接式的裝置能夠在不改變微流體晶片本身的設計的情況下輕易地套用於微流體晶片上,在本研究中我們使用低成本的環狀超聲波共振壓電片達成直接從微流體晶片噴灑出樣本的結果,並且作為微流體晶片與質譜儀分析之間的介面儀器。我們設計了一個挟持器於微流體晶片的末端,使得微流體晶片能夠挟持住環狀超聲波共振壓電片並且在不需要任何媒介,如:毛細管,的情況下就能將樣本由微流體晶片的末端向外噴灑,液體樣本於微流體晶片出口端的擴散情形以及環狀超聲波共振壓電片間歇性的噴灑情形皆受到觀察與分析,為了能夠進一步的分析環狀超聲波共振壓電片對微流體晶片上的微流道的流場影響我們加入了流場可視化粒子,於質譜儀分析之前我們先使用了基質(matrix) 作為樣本噴灑與樣本沉積的測試,後續我們展示了胜肽樣本的質譜儀分析,並且比較藉由環狀超聲波共振壓電片噴灑與傳統的滴定管移液沉積之胜肽樣本於質譜儀下的訊號強度以及均勻度,藉由環狀超聲波共振壓電片噴灑之胜肽樣本的結果顯示低使用量以及高均勻性的優點。;The interfacing methods for microfluidics to mass spectrometry should be compatible for the microfluidic chips that are already in use. An external interfacing device can be easily applied to the microfluidic chips without changing the original designs on the chips. In this study, we achieved the spray from chip by introducing a ring-shaped piezoelectric acoustic atomizer (piezo-ring), which is commercially available and low-cost, and used it as the microfluidic to MALDI – MS interfacing device. We designed a holder pattern at the outlet of the PDMS chip, making the chip be able to mount the piezo-ring and directly spray samples from the outlet without any intermedium such as capillaries. The sample spreading issue on the fluidic outlet surface was discussed and the pulsatile spraying behavior of piezo-ring was observed as well. We also added the visualize particles into the microchannel for the further evaluation of pumping effects to the microchannel by piezo-ring actuation. The deposition process of matrix was obtained before the MS analysis. The MS signals of peptides were then demonstrated by mass spectrometry and we compared the signal intensity of peptides by piezo-ring with traditional pipetting method. The low use of sample volume and uniform signal intensity were achieved by the piezo-ring-on-chip device.
    顯示於類別:[機械工程研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML284檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明