中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/93847
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 41248750      在线人数 : 39
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/93847


    题名: 基於加速度計低功耗精確量測步數演算法在穿戴式裝置的實現;Low Power Implementation of an Accurate Accelerometer-Based Step Counting Algorithm in Wearable Device
    作者: 官敬堯;Kuan, Ching-Yao
    贡献者: 機械工程學系
    关键词: 量測步數;計算時間;自相關函數;穿戴式裝置;功耗;step counting;computation time;autocorrelation function;wearable device;power consumption
    日期: 2023-08-01
    上传时间: 2024-09-19 17:41:59 (UTC+8)
    出版者: 國立中央大學
    摘要: 近年來,每日的行走步數普遍被視為自我健康監測的指標,市面上已有許多穿戴式裝置都具計算行走步數的功能,若能開發一種低功耗且精確量測步數的演算法,則能夠減少裝置的充電次數,進而提升裝置的方便程度以及延長其電池壽命。我們以自適性自相關函數計步(Adaptive Autocorrelation Step Counting, APASC)演算法為基礎,分析並最佳化其核心演算法自相關函數的計算量,再簡化此演算法的流程,提出一種低功耗的自適性自相關函數計步(Low Power Adaptive Autocorrelation Step Counting, LPAPASC)演算法,我們對此演算法進行了準確度分析,並在穿戴式裝置上實現之。最終,本研究提出的LPAPASC演算法與APASC演算法相比,在長達22小時的資料測試中,其準確率僅降低0.86%。然而,LPAPASC演算法在穿戴式裝置上的執行所需的耗電量卻比APASC演算法降低了88%。;In recent years, the number of steps taken per day has generally been regarded as an indicator of self-health monitoring. There are many wearable devices on the market track user′s daily step count. If an algorithm with low power consumption and accurate step measurement can be developed, the charging times of the device can be reduced, thereby improving the convenience of the device and prolonging its battery life. Based on the Adaptive Autocorrelation Step Counting (APASC) algorithm, we analyze and optimize the calculation amount of the autocorrelation function of its core algorithm, then simplify the process of this algorithm, propose Low Power Adaptive Autocorrelation Step Counting (LPAPASC) algorithm and implemented it in wearable device. Finally, compared with the APASC algorithm, the accuracy of the LPAPASC algorithm proposed in this study is only reduced by 0.86% in the 22-hour data test. However, the power consumption required for the execution of the LPAPASC algorithm in wearable device is 88% lower than that of the APASC algorithm.
    显示于类别:[機械工程研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML15检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明