參考文獻 |
[1] S. Wischnitzer, Introduction to Electron Microscopy (Pergamon Press, 1981).
[2] J. Chen, Introduction to Scanning Tunneling Microscopy (University Press, Oxford, 1993).
[3] D. W. Pohl and D. Courjon, eds., Near-Field Optics (Kluwer Academic, Dordrecht;Boston, 1993).
[4] M. Abramowitz, “Fluorescence Microscopy: The Essentials,” Olympus America, Inc., New York, 43 (1993).
[5] C. J. R. Sheppard and D. M. Shotton, “Confocal Laser Scanning Microscopy,” BIOS Scientific Publishers Ltd., Oxford, UK, 106 (1997).
[6] W. Denk, J. H. Strickler, and W. W. WEBB, “Two-Photon Laser Scanning Fluorescence Microscopy,” Science 248 , 73-76 (1990).
[7] E. Abbe, “Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung,” Arch. Mikrosk. Anat. 9, 413 (1873).
[8] S. W. Hell and J. Wichmann, “Breaking the diffraction resolution limit by stimulated emission:stimulated emission depletion fluorescence microscopy,“ Opt. Lett. 19, 780-782 (1994).
[9] S. W. Hell, M. Dyba1 and S. Jakobs, “Concepts for nanoscale resolution in fluorescence microscopy,” Curr. Opin. Neurobiol. 14, 599-609 (2004).
[10] S. W. Hell, “Far-field optical nanoscopy,” Science 316, 1153-1158 (2007).
[11] G. Vicidomini, G. Moneron, K. Y. Han, V. Westphal, H. Ta, M. Reuss, J. Engelhardt, C. Eggeling, and S. W. Hell, “Sharper low-power STED nanocopy by time gating,” Nat. Methods 4, 1-3 (2011).
[12] E. Abbe, “Beitrage zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung,” M. Schultze’s Archiv fur mikroskopische Anatomie 4, 413-468 (1873).
[13] http://www.doitpoms.ac.uk/tlplib/diffraction/image.php
[14] R. Heintzmann and C. Cremer, “Laterally modulated excitation microscopy: Improvement of resolution by using a diffraction grating,” Proc. SPIE 3568, 185-196 (1998).
[15] B. Fain and P. Milonni, “Classical stimulated emission,” J. Opt. Soc. Am. B 4, 78-85 (1987).
[16] M. J. Rust, M. Bates, and X. Zhuang, “Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM),” Nat. Methods 3, 793-796 (2006)
[17] G. Moneron and S. W. Hell, “Two-photon excitation STED microscopy,” Opt. Express 17, 14567-14573 (2009).
[18] B. Valeur, Molecular Fluorescence: Principles and Applications (Wiley-VCH, Weinheim, 2002).
[19] http://photochemistryportal.net/home/index.php/category/principles/
[20] S. W. Hell, ‘‘Increasing the resolution of far-field fluorescence light microscopy by point-spread-function engineering,’’ in Topics in Fluorescence Spectroscopy, J. R. Lakowicz, Ed. 5, 361-422 (2002).
[21] T. A. Klar, E. Engel, and S. W. Hell, “Breaking Abbe’s diffraction resolution limit in fluorescence microscopy,” Phys. Rev. E 64, 066613 (2001).
[22] B. Harke, J. Keller, C. K. Ullal, V. Westphal, A. Schönle, and S.W. Hell, “Resolution scaling in STED microscopy,” Opt. Express 16, 4154-4162 (2008).
[23] D. Wildanger, R. Medda, L. Kastrup, and S. W. Hell, “A compact STED microscope providing 3D nanoscale resolution” Jour. of Microcopy 236, 35-43 (2009).
[24] K. I Willig, B. Harke, R. Medda, and S.W. Hell, “STED microscopy with continuous wave beams,” Nat. Methods 4, 915-918 (2007).
[25] B. Richards and E. Wolf, “Electromagnetic diffraction in optical systems. II. Structure of the image field in an aplanatic system,” Proc. Roy. Soc. A 253, 358-379 (1959).
[26] B. Richards and E. Wolf, “Electromagnetic diffraction in optical systems. II. Structure of the image field in an aplanatic system,” Proc. Roy. Soc. A 253, 358–379 (1959).
[27] L. Allen, M. W. Beijersbergen, R. J. C. Spreeuw, and J. P. Woerdman, “Orbital angular-momentum of light and the transformation of Laguerre-Gaussian laser modes,” Phys. Rev. A 45, 8185-8189 (1992).
[28] M. W. Bejersbergen, L. Allen, H. E. L. O. van der Veen, and J. P. Woerdman, “Astigmatic laser mode converters and transfer of orbital angular momentum,” Opt. Commun. 96, 123-132 (1993).
[29] T. Watanabe, M. Fujii, Y. Watanabe, N. Toyama, and Y. Iketaki, “Generation of a doughnut-shaped beam using a spiral phase plate,” Rev. Sci. Instrum. 75, 5131-5135 (2004).
[30] K. S. Youngworth and T. G. Brown, “Focusing of high numerical aperture cylindrical-vector beams,” Opt. Express 7, No. 2, 77-87 (2000).
[31] Y. Y. Tzeng, S. W. Ke, C. L. Ting, Andy Y. G. Fuh, and T. H. Lin, “Axially symmetric polarization converters based on photo-aligned liquid crystal films,” Opt. Express 16, No. 6, 3768-3775 (2008).
[32] G. Moneron, R. Medda, B. Hein, A. Giske, V. Westphal, and S.W. Hell, “Fast STED microscopy with continuous wave fiber lasers,” Opt. Express 18, 1302-1309 (2010).
[33] A. Cser, K. Nagy and L. Biczok, “Fluorescence lifetime of Nile Red as a probe for the hydrogen bonding strength with its microenvironment,” Chem. Phys. Lett. 360, 473-478 (2002).
[34] http://products.invitrogen.com/ivgn/product/F8784?ICID==%3D%3D%3D%3D%3Dsearch-product |