參考文獻 |
[1]行政院衛生署國民健康局,民國97年癌症年度報告。
http://www.bhp.doh.gov.tw/BHPnet/Portal/StatisticsShow.aspx?No=200911300001
[2]美國癌症聯合委員會。
http://www.cancerstaging.org/mission/whatisajcc.html
[3]W. A. Berg, L. Gutierrez, M. S. NessAiver, W. B. Carter, M. Bhargavan, R. S. Lewis,O. B. Ioffe, “Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer,” Radiology, Vol. 233, pp. 830-849 (2004).
[4]A. Webb, Introduction to Biomedical Imaging, John Wiley & Sons, Inc., New Jersey (2003).
[5]M. Cutler, “Transillumination as an aid in the diagnosis of breast lesions,” Surgery, Gynecology and Obstetrics, Vol. 48, pp. 721-727 (1929).
[6]J. D. Hardy and C. Muschenheim, “The radiation of heat from the human body. IV. the emission, reflection, and transmission of infra-red radiation by the human skin,” Journal of Clinical Investigation, Vol. 13, No. 5, pp. 817-831 (1934).
[7]B. L. Horecker, “The absorption spectra of hemoglobin and its derivatives in the visible and near infra-red regions,” Journal of Biological Chemistry, Vol. 148, pp. 173-183 (1943).
[8]F. F. Jobsis, “Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters,” Science, Vol. 198, No. 4323, pp. 1264-1267 (1977).
[9]H. Q. Woodard and D. R. White, “The composition of body tissues,” British Journal of Radiology, Vol. 59, pp. 1209-1219 (1986).
[10]D. R. White, H. Q. Woodard and S. M. Hammond, “Average soft-tissue and bone models for use in radiation dosimetry,” British Journal of Radiology, Vol. 60, pp. 907-913 (1987).
[11]B. L. Hart, R. T. Steinbock, F. A. Mettler, D. R. Pathak and S. A. Bartlow, “Age and race changes in mammographic parenchymal patterns,” Cancer, Vol. 63, pp. 2537-2539 (1989).
[12]A. E. Profio and G.. A. Navarro, “Scientific basis of breast diaphanography,” Medical Physics, Vol. 16, pp. 60-65 (1989).
[13]S. Singh, “Refractive index measurement and its applications,” Physica Scripta, Vol. 65, pp. 167-180 (2002).
[14]H. J. van Staveren, C. J. M. Moes, J. van Marle, S. A Prahl and M. J. C van Gemert, “Light scattering in Intralipid-10% in the wavelength range of 400-1100 nm,” Applied Optics, Vol. 30, pp. 4507-4514 (1991).
[15]R. Michels, F. Foschum and A. Kienle, “Optical properties of fat emulsions,” Optical Express, Vol. 16, pp. 5907-5925 (2008).
[16]S. J. Madsen, M. S. Patterson and B. C. Wilson, “The use of India ink as an optical absorber in tissue-simulating phantoms,” Physics in Medicine and Biology, Vol. 37, Issue 4, pp. 985-993 (1992).
[17]J. Swartling, J. S. Dam and A. E. Stefan, ”Comparison of spatially and temporally resolved diffuse-reflectance measurement systems for determination of biomedical optical properties,” Applied Optics, Vol. 42, No. 22, pp. 4612-4620 (2003).
[18]B. A. Brooksby, ”Combining near infrared tomography and magnetic resonance imaging to improve breast tissue chromophore and scattering assessment,” Doctoral thesis, Dartmouth College (2005/5).
[19]J. B. Fishkin, E. Gratton, M. J. van de Ven and W. W. Mantulin, “Diffusion of intensity modulated near-infrared light in turbid media,” Proceedings of SPIE-The International Society for Optical Engineering, Vol. 1431, pp. 122-135 (1991).
[20]T. Tu, Y. Chen, J. Zhang, X. Intes and B. Chance, “Analysis on performance and optimization of frequency-domain near-infrared instruments,” Journal of Biomedical Optics, Vol. 7, No. 4, pp. 643-649 (2002).
[21]Q. Zhu, M. Huang, N. Chen, K. Zarfos, B. Jagjivan, M. Kane, P. Hedge and S. H. Kurtzman, “Ultrasound-guided optical tomographic imaging of malignant and benign breast lesions: initial clinical results of 19 cases,” Neoplasia, Vol. 5, No. 5, pp. 379-388 (2003).
[22]R. Choe, “Diffuse optical tomography and spectroscopy of breast and fetal brain,” Doctoral thesis, Pennsylvania University (2005).
[23]S. Jiang, B. W. Pogue and K. D. Paulsen, “Dynamic frequency domain tomography system and phantom test,” Proceedings of SPIE, Multimodal Biomedical Imaging II, Vol. 6431.pp. 64310G (2007).
[24]J. Y. Chen, H. Z. Jiang, L. Y. Chen, M. C. Pan, C. T. Wu and M. C. Pan, “Breast tumor detection instrument through mammography based NIR DOT,” Journal of Medical Devices, Vol. 4, Issue 2, 027529 (2010).
[25]L. V. Wang, H. I. Wu, Biomedical optics: principles and imaging, John Wiley & Sons, Inc., New Jersey (2007).
[26]V. V. Tuchin, Tissue optics: light scattering methods and instruments for medical diagnosis, 2nd edition, SPIE Press, Bellingham, Washington, USA (2007).
[27]R. Nave , Rayleigh and Mie scattering of incident light
http://hyperphysics.phy-astr.gsu.edu/hbase/atmos/blusky.html
[28]乳癌健康中心。http://www.webmd.com/breast-cancer/guide/breast-cancer-normal-breast
[29]R. L. Egan, Breast Embryology, Anatomy and Physiology. Breast Imaging: Diagnosis and Morphology of Breast Diseases (1988)
[30]R. Cubeddu, A. Pifferi, P. Taroni, A. Torricelli, and G. Valentini, “Noninvasive absorption and scattering spectroscopy of bulk diffusive media: an application to the optical characterization of human breast,” Applied Optics, Vol. 74, No.6, pp 874-876 (1999).
[31]B. W. Pogue, S. Jiang, H. Dehghani, C. Kogel, S. Soho, S. Srinivasan, X. Song, T. D. Tosteson, S. P. Poplack, K. D. Paulsen, “Characterization of hemoglobin, water, and NIR scattering in breast tissue: analysis of intersubject variability and menstrual cycle changes,” Journal of Biomedical Optics, Vol. 9. No.3, pp 541-552 (2004).
[32]F. E. W. Schmidt, “Development of a time-resolved optical tomography system for neonatal brain imaging,” Doctoral thesis, London University (1999/11).
[33]B. J. Tromberg, A. E. Cerussi, D. Jakubowski, N. Shah, F. Bevilacqua, A. J. Berger, J. Butler, R. F. and Holcombe, “Functional diffuse optical spectroscopy of human breast tissue,” The 14th Annual Meeting of the IEEE, Vol. 1, pp. 259-260 (2001/01).
[34]V. G. Peters, D. R. Wyman, M. S. Patterson and G. L. Frank, “Optical properties of normal and diseased human breast tissues in the visible and near infrared, ” Physics in Medicine and Biology, Vol. 35, No 9, pp. 1317-1334 (1990).
[35]T. L. Troy, D. L. Page and E. M. Sevick-Muraca, “Optical properties of normal and diseased breast tissues, “Journal of the Optical Society of America, Vol. 3, pp. 59-66 (1996).
[36]L. Wang, P. P. Ho, C. Liu, G. Zhang, R. R. Alfano, “Ballistic 2-D imaging through scattering walls using an ultrafast optical kerr gate,” Science ,Vol. 253 No. 5021 pp. 769-771 (1991).
[37]J. B. Fishkin and E. Gratton, “Propagation of photon-density waves in strongly scattering media containing an absorbing semi-infinite plane bounded by a straight edge, ” Journal of the Optical Society of America ,Vol. 10, Issue 1, pp. 127-140 (1993).
[38]B. W. Pogue, M. Testorf, T. O. McBride, U. Osterberg and K. Paulsen, “Instrumentation and design of a Frequency-domain diffuse optical tomography imager for breast cancer detection,” Optical Express, Vol. 1, pp. 391-403 (1997).
[39]楊國輝,黃宏彥,雷射原理與量測概論,五南圖書出版公司,臺北 (2008)。
[40]B. Letus, “Wavelength tuneable Frequency domain photon migration spectrometer for tissue-like media,” Doctoral thesis, Waikato University (2010/5).
[41]B. W. Pogue, K. D. Paulsen, H. Kaufman and C. Abele, “Calibration of near-infrared frequency-domain tissue spectroscopy for absolute absorption coefficient quantitation in neonatal head-simulating phantoms,” Journal of Biomedical Optics, Vol. 5, pp. 185-193 (2000).
[42]B. W. Pouge and M. S. Patterson, “Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry, ”Journal of Biomedical Optics, Vol.11, No. 4, 041102 (2006).
[43]T. Moffitt, Y. C. Chen and S. A. Prahl, “Preparation and characterization of polyurethane optical phantoms”, Journal of Biomedical Optics, Vol.11, No. 4, 041103 (2006).
[44]S. A. Prahl, “Inverse adding-doubling for optical property measurements,” Oregon Medical Laser Center (2007).(http://omlc.ogi.edu/sitemap/index.html)
[45]T. O. McBride, “Spectroscopic reconstructed near infrared tomographic imaging for breast cancer diagnosis,” Dartmouth College, Ph.D. thesis (2001/5).
[46]W. F. Cheong, S. A. Prahl and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE Journal of Quantum Electronics, Vol.26, pp. 2166-2185 (1990)
|