參考文獻 |
[1] Philip, W., Brien, R. L., & William, E. L. (Eds.), Osseointegration in dentistry: An Introduction., Quintessence Publishing Co. Inc., Chicago, 1994.
[2] Brånemark, P-I., Zarb, G. A., & Albrektsson, T. (Eds.), Tissue-integrated prostheses: Osseointegration in clinical dentistry., Quintessence Publishing Co. Inc., Chicago, 1985.
[3] Atsumi, M., Park, S. H. and Wang, H. L., “Methods used to assess implants stability: Current status,” The International Journal of Oral & Maxillofacial Implants, Vol. 22, No. 5, pp. 743-754 (2007).
[4] Javed, F. and Romanos, G. E., “The role of primary stability for successful immediate loading of dental implant: A literature review,” Journal of Dentistry, Vol. 38, No. 8, pp. 612-620 (2010).
[5] Araújo, M. G., Sukekava, F., Wennström, J. and Lindhe, J., “Ridge alterations following implant placement in fresh extraction sockets: An experimental study in the dog,” Journal of Clinical Periodontology, Vol. 32, No. 6, pp. 645-652 (2005).
[6] Huang, H. L., Chang, Y. Y., Lin, D. J., Li, Y. F., Chen, K. T. and Hsu, J. T., “Initial stability and bone strain evaluation of the immediately loaded dental implant: An in vitro model study,” Clinical Oral Implants Research, Vol. 22, No. 7, pp. 691-698 (2011).
[7] Berglundh, T., Abrahamsson, I., Lang, N. P. and Lindhe, J., “De novo alveolar bone formation adjacent to endosseous implants: A model study in the dog,” Clinical Oral Implants Research, Vol. 14, No. 3, pp. 251-262 (2003).
[8] Chang, P-C., Lang, N. P. and Giannobile, W. V., “Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants,” Clinical Oral Implants Research, Vol. 21, No. 1, pp. 1-12 (2010).
[9] Carlo, T. and Stefano, P-B., “Clinical classification of bone defects concerning the placement of dental implants,” The International Journal of Periodontics & Restorative Dentistry, Vol. 23, No. 2, pp. 147-155 (2003).
[10] Leonardo, V. B., “A proposal for the classification of bony defects adjacent to dental implants,” The International Journal of Periodontics & Restorative Dentistry, Vol. 24, No. 3, pp. 264-271 (2004).
[11] Schwarz, F., Herten, M., Sager, M., Bieling, K., Sculean, A. and Becker, J., “Comparison of naturally occurring and ligature-induced peri-implantitis bone defects in humans and dogs,” Clinical Oral Implants Research, Vol. 18, No. 2, pp. 161-170 (2007).
[12] Johansson, C. B., Han, C. H., Wennerberg, A. and Albrektsson, T., “A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone,” The International Journal of Oral & Maxillofacial Implants, Vol. 13, No. 3, pp. 315-321 (1998).
[13] Berzins, A., Shah, B., Weinans, H. and Summer, D. R., “Nondestructive measurements of implant-bone interface shear modulus and effects of implant geometry in pull-out tests,” Journal of Biomedical Materials Research Part A, Vol. 34, No. 3, pp. 337-340 (1997).
[14] Kitsugi, T., Nakamura, T., Oka, M., Yan, W. Q., Goto, T., Shibuya, T., Kokubo, T. and Miyaji, S., “Bone bonding behavior of titanium and its alloys when coated with titanium oxide (TiO2) and titanium silicate (Ti5Si3),” Journal of Biomedical Materials Research Part A, Vol. 32, No. 2, pp. 149-156 (1996).
[15] Brånemark, R., Ohrnell, L. O., Skalak, R., Carlsson, L. and Brånemark, P-I., “Biomechanical characterization of osseointegration: An experimental in vivo investigation in the beagle dog,” Journal of Orthopaedic Research, Vol. 16, No. 1, pp. 61-69 (1998).
[16] Brunski, J. B., Puleo, D. A. and Nanci, A., “Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments,” The International Journal of Oral & Maxillofacial Implants, Vol. 15, No. 1, pp. 15-46 (2000).
[17] Meredith, N., Shagaldi, F., Alleyne, D., Sennerby, L. and Cawley, P., “The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia,” Clinical Oral Implants Research, Vol. 8, No. 3, pp. 234-243 (1997).
[18] Friberg, B., Sennerby, L., Roos, J., Johansson, P., Strid, C. G. and Lekholm, U., “Evaluation of bone density using cutting resistance measurements and microradiography: An in vitro study in pig ribs,” Clinical Oral Implants Research, Vol. 6, No. 3, pp. 164-171 (1995).
[19] Ueda, M., Matsuki, M., Jacobsson, M. and Tjellström, A., “Relationship between insertion torque and removal torque analyzed in fresh temporal bone,” The International Journal of Oral & Maxillofacial Implants, Vol. 6, No. 4, pp. 442-447 (1991).
[20] O’Sullivan, D., Sennerby, L. and Meredith, N., “Measurements comparing the initial stability of five designs of dental implants: A human cadaver study,” Clinical Implant Dentistry and Related Research, Vol. 2, No. 2, pp. 85-92 (2000).
[21] Molly, L., “Bone density and primary stability in implant therapy,” Clinical Oral Implants Research, Vol. 17, No. S2, pp. 124-135 (2006).
[22] Aparicio, C., Lang, N. P. and Rangert, B., “Validity and clinical significance of biomechanical testing of implant/bone interface,” Clinical Oral Implants Research, Vol. 17, No. S2, pp. 2-7 (2006).
[23] Schulte, W. and Lukas, D., “Periotest to monitor osseointegration and to check the occlusion in oral implantology,” Journal of Oral Implantology, Vol. 19, No. 1, pp.23-32 (1993).
[24] Olivé, J. and Aparicio, C., “Periotest method as a measure of osseointegrated oral implant stability,” The International Journal of Oral & Maxillofacial Implants, Vol. 5, No. 4, pp. 390-400 (1990).
[25] Schulte, W. and Lukas, D., “The Periotest method,” International Dental Journal, Vol. 42, No. 6, pp. 433-440 (1992).
[26] Meredith, N., Alleyne, D. and Cawley. P., “Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis,” Clinical Oral Implants Research, Vol. 7, No. 3, pp. 261-267 (1996).
[27] Meredith, N., “A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants,” Critical Reviews in Biomedical Engineering, Vol. 26, No. 4, pp. 275-291 (1998).
[28] Sennerby, L. and Meredith, N., “Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications,” Periodontology 2000, Vol. 47, No. 1, pp. 51-66 (2008).
[29] Kay, M. W., Roe, S. C., Stikeleather, L. F., Mahmoud, A. and Abrams, C. F. Jr., “Axial vibration of threaded external fixation pins: Detection of pin loosening,” Annals of Biomedical Engineering, Vol. 26, No. 3, pp. 361-368 (1998).
[30] Huang, H. M., Lee, S. Y., Yeh, C. Y. and Lin, C. T., “Resonance frequency assessment of dental implant stability with various bone qualities: A numerical approach,” Clinical Oral Implants Research, Vol. 13, No. 1, pp. 65-74 (2002).
[31] Huang, H. M., Chiu, C. L., Yeh, C. Y. and Lee, S. Y., “Factors influencing the resonance frequency of dental implants,” Journal of Oral and Maxillofacial Surgery, Vol. 61, No. 10, pp. 1184-1188 (2003).
[32] Huang, H. M., Chiu, C. L., Yeh, C. Y., Lin, C. T., Lin, L. H. and Lee, S. Y., “Early detection of implant healing process using resonance frequency analysis,” Clinical Oral Implants Research, Vol. 14, No. 4, pp. 437-443 (2003).
[33] Huang, H. M., Cheng, K. Y., Lin, C. T., Huang, W. J., Yao, W. C., Cheng, P. Y. and Lee, S. Y., “Examination of a novel designed device used for dental implants stability detection - An animal study,” Journal of Medical and Biological Engineering, Vol. 24, No. 3, pp. 115-162 (2004).
[34] Huang, H. M., Cheng, K. Y., Chen, C. F., Ou, K. L., Lin, C. T. and Lee, S. Y., “Design of a stability-detecting device for dental implants,” Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine, Vol. 219, No. 3, pp. 203-211 (2005).
[35] Chang, W. J., Lee, S. Y., Wu, C. C., Lin, C. T., Abiko, Y., Yamamichi, N. and Huang, H. M., “A newly designed resonance frequency analysis device for dental implant stability detection,” Dental Materials Journal, Vol. 26, No. 5, pp. 665-671 (2007).
[36] Yamane, M., Yamaoka, M., Hayashi, M., Furutoyo, I., Komori, N. and Ogiso, B., “Measuring tooth mobility with a no-contact vibration device,” Journal of Periodontal Research, Vol. 43, No. 1, pp.84-89 (2008).
[37] Hayashi, M., Kobayashi, C., Ogata, H., Yamaoka, M. and Ogiso, B., “A no-contact vibration device for measuring implant stability,” Clinical Oral Implants Research, Vol. 21, No. 9, pp. 931-936 (2010).
[38] Kim, D. S., Lee, W. J., Choi, S. C., Lee, S. S., Heo, M. S., Huh, K. H., Kim, T. I., Lee, I. B., Han, J. H. and Yi, W. J., “A new method for the evaluation of dental implant stability using an inductive sensor,” Medical Engineering & Physics, Vol. 34, No. 9, pp. 1247-1252 (2012).
[39] Ito, Y., Sato, D., Yoneda, S., Ito, D., Kondo, H. and Kasugai, S., “Relevance of resonance frequency analysis to evaluate dental implant stability: Simulation and histomorphometrical animal experiments,” Clinical Oral Implants Research, Vol. 19, No. 1, pp. 9-14 (2008).
[40] Tözüm, T. F., Turkyilmaz, I. and McGlumphy, E. A., “Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects: An in vitro study,” Journal of Oral Rehabilitation, Vol. 35, No. 10, pp. 739-744 (2008).
[41] Hsu, J. T., Fuh, L. J., Tu, M. G., Li, Y. F., Chen, K. T. and Huang, H. L., “The effects of cortical bone thickness and trabecular bone strength on noninvasive measures of the implant primary stability using synthetic bone models,” Clinical Implant Dentistry and Related Research, Vol. 15, No. 2, pp. 251-261 (2013).
[42] Toyoshima, T., Wagner, W., Klein, M. O., Stender, E., Wieland, M. and Al-Nawas, B., “Primary stability of a hybrid self-tapping implant compared to a cylindrical non-self-tapping implant with respect to drilling protocols in an ex vivo model,” Clinical Implant Dentistry and Related Research, Vol. 13, No. 1, pp. 71-78 (2011).
[43] Pattijn, V., Jaecques, S. V. N., De Smet, E., Muraru, L., Van Lierde, C., Van der Perre, G., Naret, I. and Vander Sloten, J., ”Resonance frequency analysis of implants in the guinea pig model: Influence of boundary conditions and orientation of the transducer,” Medical Engineering & Physics, Vol. 29, No. 2, pp. 182-190 (2007).
[44] Xiao, J. R., Li, Y. Q., Guan, S. M., Kong, L., Liu, B. and Li, D., “Effects of lateral cortical anchorage on the primary stability of implants subjected to controlled loads: An in vitro study,” British Journal of Oral and Maxillofacial Surgery, Vol. 50, No. 2, pp. 161-165 (2012).
[45] Dilek, O., Tezulas, E. and Dincel, M., “Required minimum primary stability and torque values for immediate loading of mini dental implants: An experimental study in nonviable bovine femoral bone,” Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, Vol. 105, No. 2, pp. e20-e27 (2008).
[46] Schouten, C., Meijer, G. J., van den Beucken, J. J. J. P., Spauwen, P. H. M. and Jansen, J. A., “A novel implantation model for evaluation of bone healing response to dental implants: The goat iliac crest,” Clinical Oral Implants Research, Vol. 21, No. 4, pp. 414-423 (2010).
[47] Turkyilmaz, I., Sennerby, L., Yilmaz, B., Bilecenoglu, B. and Ozbek, E. N., “Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: A human cadaver study,” Clinical Implant Dentistry and Related Research, Vol. 11, No. 1, pp. 52-58 (2009).
[48] Tözüm, T. F., Bal, B. T., Turkyilmaz, I., Gülay, G. and Tulunoglu, I., “Which device is more accurate to determine the stability/mobility of dental implants? A human cadaver study,” Journal of Oral Rehabilitation, Vol. 37, No. 3, pp. 217-224 (2010).
[49] Çehreli, M. C., Kökat, A. M., Cömert, A., Akkocaoğlu, M., Tekdemir, I. and Akça, K., “Implant stability and bone density: Assessment of correlation in fresh cadavers using conventional and osteotome implant sockets,” Clinical Oral Implants Research, Vol. 20, No. 10, pp. 1163-1169 (2009).
[50] Akça, K., Kökat, A. M., Cömert, A., Akkocaoğlu, M., Tekdemir, I. and Çehreli, M. C., “Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro,” International Journal of Oral & Maxillofacial Surgery, Vol. 39, No. 2, pp. 169-173 (2010).
[51] De Smet, E., Jaecques, S., Vandamme, K., Vander Sloten, J. and Naert, I., “Positive effect of early loading on implant stability in the bi-cortical guinea-pig model,” Clinical Oral Implants Research, Vol. 16, No. 4, pp. 402-407 (2005).
[52] Valderrama, P. Oates, T. W., Jones, A. A., Simpson, J., Schoolfield, J. D. and Cochran, D. L., “Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial,” Journal of Periodontology, Vol. 78, No. 2, pp. 262-272 (2007).
[53] Geng, J. P., Tan, K. B. C. and Liu, G. R., “Application of finite element analysis in implant dentistry: A review of the literature,” The Journal of Prosthetic Dentistry, Vol. 85, No. 6, pp. 585-598 (2001).
[54] Van Staden, R. C., Guan, H. and Loo, Y. C., “Application of the finite element method in dental implant research,” Computer Methods in Biomechanics and Biomedical Engineering, Vol. 9, No. 4, pp. 257-270 (2006).
[55] Ladd, A. J. C. and Kinney, J. H., “Numerical errors and uncertainties in finite-element modeling of trabecular bone,” Journal of Biomechanics, Vol. 31, No. 10, pp. 941-945 (1998).
[56] Pattijn, V., Van Lierde, C., Van der Perre, G., Naert, I. and Vander Sloten, J., “The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach,” Journal of Biomechanics, Vol. 39, No. 5, pp. 939-947 (2006).
[57] Capek, L., Simunek, A., Slezak, R. and Dzan, L., “Influence of the orientation of the Osstell® transducer during measurement of dental implant stability using resonance frequency analysis: A numerical approach,” Medical Engineering & Physics, Vol. 31, No. 7, pp. 764-769 (2009).
[58] Natali, A. N., Pavan, P. G., Schileo, E. and Williams, K. R., “A numerical approach to resonance frequency analysis for investigation of oral implant osseointegration,” Journal of Oral Rehabilitation, Vol. 33, No. 9, pp. 674-681 (2006).
[59] Wang, K., Li, D. H., Guo, J. F., Liu, B. L. and Shi, S. Q., “Effects of buccal bi-cortical anchorages on primary stability of dental implants: A numerical approach of natural frequency analysis,” Journal of Oral Rehabilitation, Vol. 36, No. 4, pp. 284-291 (2009).
[60] Cawley, P. and Pettersson, A., “Method and arrangement relating to testing objects,” United States Patent, Patent No.: US 8,391,958 B2 (2013).
[61] Huang, H. M., Pan, L. C., Lee, S. Y., Chiu, C. L., Fan, K. H. and Ho, K. N., “Assessing the implant/bone interface by using natural frequency analysis,” Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, Vol. 90, No. 3, pp. 285-291 (2000).
[62] Yajima, T., “Measurement of mechanical impedance of the human tooth (quantitative measurements of the periodontal viscosity and elasticity relating to tooth mobility),” Kōkūbyō Gakkai Zasshi. The Journal of the Stomatological Society, Japan, Vol. 38, No. 4, pp. 556-573 (1971).
[63] Lee, H. H., Finite element simulations with ANSYS Workbench 12: Theory-applications-case studies., Gotop Information Inc., Taipei, 2010.
[64] SWBONES®, Custom orthopedic and medical models for training., Pacific Research Laboratories, Inc., USA, 2012.
[65] Vignoletti, F. and Abrahamsson, I., “Quality of reporting of experimental research in implant dentistry. Critical aspects in design, outcome assessment and model validation,” Journal of Clinical Periodontology, Vol. 39, Suppl. 12, pp. 6-27 (2012).
[66] Stadlinger, B., Pourmand, P., Locher, M. C. and Schulz, M. C., “Systematic review of animal models for the study of implant integration, assessing the influence of material, surface and design,” Journal of Clinical Periodontology, Vol. 39, Suppl. 12, pp. 28-36 (2012). |