博碩士論文 100022007 完整後設資料紀錄

DC 欄位 語言
DC.contributor遙測科技碩士學位學程zh_TW
DC.creator張凱威zh_TW
DC.creatorKai-Wei Changen_US
dc.date.accessioned2013-7-17T07:39:07Z
dc.date.available2013-7-17T07:39:07Z
dc.date.issued2013
dc.identifier.urihttp://ir.lib.ncu.edu.tw:88/thesis/view_etd.asp?URN=100022007
dc.contributor.department遙測科技碩士學位學程zh_TW
DC.description國立中央大學zh_TW
DC.descriptionNational Central Universityen_US
dc.description.abstract高光譜紅外輻射儀以及掩星技術之觀測皆提供大量的大氣觀測,而先前研究指出此兩種觀測擁有互補之性質。來自高光譜紅外線觀測的溫度反演,在高對流層以及低平流層之區域常有較大的誤差,而掩星觀測在此高度則是擁有相對較高的準確度。因此,若結合掩星以及高光譜之觀測,則可能改善原單以紅外線反演得到的溫度與溼度垂直剖面。此研究提出一項同時使用掩星折射率以及紅外線亮溫之反演演算法,用於溫度以及溼度的垂直剖面反演。使用此研究中提出之反演法所得到的溫度剖面,在 100 百帕到 300 百帕之間,其均方根差之降低大約為 24%(0.36K;與再分析場比較時)與35%(0.66K;與探空感測比較時)。在高對流層對於溫度反演有所改進之外,溼度的反演上亦有改善,在100 百帕以下的平均均方根差之降低最大高達 43%(0.57g/kg)。研究中提出的演算法所得到的反演產品,與再分析場以及探空氣球觀測之各項比較後,其溼度反演之準確度於每項實驗皆優於單以紅外亮溫反演的產品,而其溫度反演則是在高層對流層上之改善最為顯著。zh_TW
dc.description.abstractHyperspectral infrared spectrometers and the radio occultation (RO) technique have become crucial for observing the atmosphere, and past studies showed that these two types of observations have complementary characteristics. Temperature retrievals from infrared sounders, such as the Atmospheric InfraRed Sounder (AIRS), tend to have higher error in the upper troposphere. In contrast, radio occultation measurements have a high vertical resolution, are highly accurate for temperature estimates in the upper troposphere and lower stratosphere, and can potentially be used to improve radiance-based temperature estimates. This study presents a physical-statistical algorithm which uses RO-derived refractivity and spectrometer radiances simultaneously to estimate temperature and humidity vertical profiles, demonstrated with measurements from FORMOSAT-3/COSMIC and AIRS. Comparison of simultaneously derived profiles and AIRS-alone derived profiles showed that the impact of RO observations to be most apparent in the upper troposphere between 100 hPa and 300hPa, where it reduced the root-mean-square difference of estimated temperature with a minimum reduction of 24\% (0.36 K) and a maximum of 35\% (0.66 K). In addition to having improved temperature profile retrievals in the upper troposphere, the humidity retrievals were also improved; the average root-mean-square difference below 100 hPa was reduced up to 43\% (0.57 g/kg) in comparison to radiosondes. In comparison to different reanalysis datasets and radiosonde soundings, the humidity profiles retrieved using the proposed algorithm were overall better than the infrared-only retrievals in all of the comparisons, and the temperature profiles improved upon the infrared-only most notably in the upper troposphere.en_US
DC.subject高光譜zh_TW
DC.subject掩星zh_TW
DC.subject溫度反演zh_TW
DC.subject溼度反演zh_TW
DC.subject遙測zh_TW
DC.subjecthyperspectralen_US
DC.subjectradio occlutationen_US
DC.subjecttemperature retrievalen_US
DC.subjecthumiditiy retrievalen_US
DC.subjectremote sensingen_US
DC.title結合掩星折射率與高光譜紅外線觀測之大氣溫溼度垂直剖面反演zh_TW
dc.language.isozh-TWzh-TW
DC.titleThe Retrieval of Atmospheric Temperature and Humidity Using Radio Occultation Refractivity and Hyperspectral Infrared Radiancesen_US
DC.type博碩士論文zh_TW
DC.typethesisen_US
DC.publisherNational Central Universityen_US

若有論文相關問題,請聯絡國立中央大學圖書館推廣服務組 TEL:(03)422-7151轉57407,或E-mail聯絡  - 隱私權政策聲明