博碩士論文 107223030 完整後設資料紀錄

DC 欄位 語言
DC.contributor化學學系zh_TW
DC.creator劉冠宜zh_TW
DC.creatorKuan-Yi Liuen_US
dc.date.accessioned2020-7-20T07:39:07Z
dc.date.available2020-7-20T07:39:07Z
dc.date.issued2020
dc.identifier.urihttp://ir.lib.ncu.edu.tw:88/thesis/view_etd.asp?URN=107223030
dc.contributor.department化學學系zh_TW
DC.description國立中央大學zh_TW
DC.descriptionNational Central Universityen_US
dc.description.abstract本研究開發了一種簡單、靈敏且對環境友好的方法以檢測水樣中 九種 parabens 防腐劑的殘留。此方法是以超音波輔助疏水性深共熔溶 劑 乳 化 微 萃 取 法 ( Deep eutectic solvent-based ultrasound- assisted emulsification microextraction , DES-USAEME ) 從水樣中萃取待測物,再透過超高效液相層析串聯電灑游離(-)-四極桿飛行時間質譜儀(UHPLC-ESI(-)-QTOF-MS)進行測定。選擇莫耳比為 2:1 的薄荷醇(作為氫受體)和十二烷酸(作為氫供體)的疏水性深共熔溶劑作為萃取劑,因其較便宜、容易在室溫下合成且對環境友善。本研究透過 Box-Behnken Design 實驗設計法(BBD)的多變量實驗設計及反應曲面法和多變量分析(ANOVA)進行各項因子的最佳化。 所得出的最佳條件為:在離心管中將 5 mL 水樣與 500 µL DES 混合。經過充分混和後加入 50 mg NaCl,並在 65°C 的超音波水浴中震盪 20 分鐘。再以 3000 rpm 離心 10 分鐘後,取出上層並用甲醇定溶至 500 µL,最後將 2 µL 提取物直接注入 UHPLC-QTOF-MS 中進行檢測。所開發方法的定量極限(LOQ)為 1 至 3.2 ng / mL。在 Intra-day及 Inter-day 的測試中,相對標準偏差 (RSD) 皆小於 10%,且回收率為82%至 99%,顯示此方法有良好的穩定性和再現性。最佳化後的 DES-USAEME 結合高選擇性和高靈敏度的 UHPLC-ESI(-)-QTOF-MS 已成功用於檢測水樣中的 parabens 防腐劑的微量殘留。zh_TW
dc.description.abstractIn this study, a simple, sensitive, and environmental-friendly method for determining the presence of nine paraben preservatives in water samples was developed. The target analytes were efficiently extracted from water samples using a deep eutectic solvent-based ultrasound- assisted emulsification microextraction (DES-USAEME), and their determination were then performed by the combination of ultrahigh- performance liquid chromatography and electrospray ionization (-)- quadrupole time-of-flight mass spectrometry (UHPLC-ESI(-)-QTOF-MS). Due to the cost and easy synthesis at room temperature, the hydrophobic DES of choice in this study was based on the mixture of menthol (as a hydrogen bond acceptor) and dodecanoic acid (as a corresponding hydrogen bond donor) at molar ratio of 2:1. The parameters of DES-USAEME were optimized by multivariate experimental design based on Box-Behnken design (BBD) plus with response surface design and analysis of variance (ANOVA). The optimal conditions were: 5 mL of water sample mixed with 500 µL of DES in a centrifuge tube. After vortex, 50 mg of NaCl were added and sonicated for 20 min in ultrasonic bath at 65 °C. After centrifugation at 3000 rpm for 10 min, the supernatant was collected and reconstituted with methanol to 500 μL, and then 2 μL of the extract was directly injected into UHPLC-QTOF-MS for detection. The limits of quantification (LOQs) of the developed method ranged from 1 to 3.2 ng/mL. High precisions were obtained for both intra- and inter-day analysis, and ranged from 1 to 10%.Satisfactory average spiked recovery ranged from 82 to 99%. Optimal DES- iv USAEME combined with highly selective and sensitive UHPLC-ESI(-)-QTOF-MS was successfully applied for the determination of selected parabens presenatives in various water samples at trace-level.en_US
DC.subject疏水性深共熔溶劑zh_TW
DC.subject超音波輔助疏水性深共熔溶劑乳化微萃取法zh_TW
DC.subject對-羥基苯甲酸酯zh_TW
DC.subjectdeep eutectic solventen_US
DC.subjectDES-USAEMEen_US
DC.subjectparabensen_US
DC.title利用綠色溶劑結合超音波輔助液液微萃取法檢測水體中防腐劑parabens的含量zh_TW
dc.language.isozh-TWzh-TW
DC.type博碩士論文zh_TW
DC.typethesisen_US
DC.publisherNational Central Universityen_US

若有論文相關問題,請聯絡國立中央大學圖書館推廣服務組 TEL:(03)422-7151轉57407,或E-mail聯絡  - 隱私權政策聲明