博碩士論文 109326601 完整後設資料紀錄

DC 欄位 語言
DC.contributor環境工程研究所zh_TW
DC.creator阮國慶zh_TW
DC.creatorNguyen Quoc Khanhen_US
dc.date.accessioned2023-7-25T07:39:07Z
dc.date.available2023-7-25T07:39:07Z
dc.date.issued2023
dc.identifier.urihttp://ir.lib.ncu.edu.tw:88/thesis/view_etd.asp?URN=109326601
dc.contributor.department環境工程研究所zh_TW
DC.description國立中央大學zh_TW
DC.descriptionNational Central Universityen_US
dc.description.abstract活性污泥模型(ASMs)在生物處理程序的多個面向中發揮著重要作用、包括研究、 設計、控制和優化。工程人員可使用這些模型來進行預測與評估。為了獲得可靠之結果、 模式模擬必須考慮水質之分解特性的細分類。本研究探討了臺灣生活污水和工業廢水之 進流水中的化學需氧量(COD)和總氧(TN)比率。COD 比率是通過呼吸測量法進行 量測、該方法量化了生物降解過程中的氧氣攝取率(OUR)、是一種廣泛應用的技術。 TN 比率是使用轉換係數和水環境研究基金會(WERF)所描述的直接測量方法進行評 估。對這些分析結果的比較和總結將確立臺灣廢污水之水質特性方法的適用性。此外、 將使用典型的 MLE 和 OAO 程序評估 COD 和 TN 比率、並觀察本土水質的脫硝速率、 從而調整操作參數來增強除氮成效。 對於本土水質的 COD 細分類結果顯示、未過初沉池的生活污水可以分為以下幾類: 易降解 COD(SS)約佔 12.6%、緩慢降解 COD(XS)約佔 45.6%、溶解性惰性 COD(SI) 約佔 3.7%和顆粒性惰性 COD(XI)約佔 38.1%。另一方面、工業廢水的特性為 SS 約 25.4%、XS約 11.6%、SI約 30.1%和 XI約 32.9%;已過初沉池的生活污水包含 SS約 18.4%、 XS 約 57.2%、SI 約 6.6%、XI 約 17.8%。另一方面、工業廢水的特性為 SS 約 25.4%、XS 約 11.6%、SI約 30.1%和 XI約 32.9%。 根據總氮(TN)的直接測量確立了進流水的分類。在這個分類中,氨氮(SNH)約 佔 72.9%、溶解性可生物降解有機氮(SND)約佔 5.5%、不可生物降解的顆粒性有機氮 (XND)約佔 14.2%、溶解性惰性有機氮(SNI)約佔 2.8%、顆粒性惰性有機氮(XNI)約 佔總氮含量的 4.6%。對於未過初沉池的生活污水樣品、氮比率包括約 62.8%的 SNH、約 2.9%的 SND、約 18.4%的 XND、約 1.0%的 SNI和約 14.9%的 XNI。在工業廢水中、氮形式 的分佈因行業類型而異。通常、總氮的主要貢獻為 NO3 - -N 和 NO2 - -N、其中 NO3 - -N 約 佔 34.1%、NO2 - -N 約佔 16.1%、SNH約佔 20.4%、SND約佔 1.1%、XND 約佔 5.4%、SNI約 佔 8.0%、XNI 約佔 14.9%。通過利用轉換係數與質量平衡、本研究建議了新的氮轉換係 數:未過初沉池之生活污水的iN,SS為 0.03、iN,XS為 0.07、iN,SI為 0.05、iN,XI為 0.07;已過 初沉池之生活污水的iN,SS為 0.06、iN,XS為 0.06、iN,SI為 0.1、iN,XI為 0.06;而工業廢水的 iN,SS為 0.01、iN,XS為 0.06、iN,SI為 0.02、iN,XI為 0.06。 當碳氮比(C/N)不足時、脫硝能力受限、由於進流水中碳源不足、從而降低除氮效率。zh_TW
dc.description.abstractActivated sludge models (ASMs) play a significant role in numerous aspects of biological treatment processes, including research, design, control, and optimization. Handlers employ these models to make forecasts and assessments. To ensure accurate results, the model simulation must consider the subdivisions of water quality characteristics. In this study, I investigated the proportions of chemical oxygen demand (COD) and total nitrogen (TN) in the influent water quality of Taiwanese domestic and industrial wastewater. The determination of COD fractions was accomplished through a respirometry assay, which quantifies the oxygen uptake rate (OUR) during biodegradation and is a widely employed technique. The TN fractions were assessed using the conversion coefficient and the direct measurement method described by Water Environment Research Foundation (WERF). The comparative and summarizing assessment of the outcomes of these analyses ascertained the suitability of water quality characteristic methodologies in Taiwan. Furthermore, the COD and TN fractions were evaluated using a typical Modified Ludzack Ettinger (MLE) and Oxic-Anoxic-Oxic (OAO) processes, while observing the denitrification rate of local water quality. Operating parameters were adjusted to enhance nitrogen removal. The detailed classification COD results of local water quality reveal that settled domestic wastewater could be categorized as follows: readily biodegradable COD (SS) accounted for approximately 18.4%, slowly biodegradable COD (XS) represented around 57.2%, soluble inert COD (SI) accounted for approximately 6.6%, and particulate inert COD (XI) contributed about 17.8%. Raw domestic wastewater, on the other hand, consisted of about 12.6% SS, approximately 45.6% XS, around 3.7% SI, and approximately 38.1% XI. Finally, ordinary industrial wastewater was characterized by approximately 25.4% SS, around 11.6% XS, approximately 30.1% SI, and about 32.9% XI. The classification of influent based on TN (Total nitrogen) was determined through direct measurement. In this classification, for settled domestic wastewater, ammonia nitrogen (SNH) accounted for approximately 72.9%, soluble biodegradable organic nitrogen (SND) accounted for around 5.5%, particulate biodegradable organic nitrogen (XND) contributed about 14.2%, soluble inert organic nitrogen (SNI) contributed approximately 2.8%, and particulate inert organic nitrogen (XNI) accounted for approximately 4.6% of the total nitrogen content. For raw domestic wastewater, the nitrogen fractions consisted of approximately 62.8% SNH, SND around 2.9%, XND about 18.4%, SNI approximately 1.0%, and XNI around 14.9%. In industrial wastewater, the distribution of nitrogen forms varied depending on the industry type. Generally, iii NO3 - -N and NO2 - -N were the major contributors to the total nitrogen content, with NO3 - -N accounted for approximately 34.1%, NO2 - -N for around 16.1%, SNH about 20.4%, SND around 1.1%, XND approximately 5.4%, SNI around 8.0%, and XNI about 14.9% of the total nitrogen content. By applying conversion factors and utilizing mass balance, this research had generated new nitrogen conversion factors: settled domestic wastewater 0.06 for iN,SS , 0.06 for iN,XS , 0.1 for iN,SI and 0.06 for iN,XI ; raw domestic wastewater 0.03 for iN,SS , 0.07 for iN,XS , 0.05 for iN,SI and 0.07 for iN,XI ; industrial wastewater 0.01 for iN,SS , 0.06 for iN,XS , 0.02 for iN,SI and 0.06 for iN,XI . The denitrification capacity was constrained when the carbon-nitrogen (C/N) ratio was insufficient, resulting in low nitrogen removal efficiency attributable to the low carbon source in the influent.en_US
DC.subjectCOD 細分類zh_TW
DC.subjectTN 細分類zh_TW
DC.subject廢水特性zh_TW
DC.subject生活廢水zh_TW
DC.subject工業廢水zh_TW
DC.subject脫硝zh_TW
DC.subjectCOD fractionsen_US
DC.subjectTN fractionsen_US
DC.subjectwastewater characteristicsen_US
DC.subjectdomestic wastewateren_US
DC.subjectindustrial wastewateren_US
DC.subjectdenitrificationen_US
DC.title廢水處理廠 COD 和 TN 水質細分類 與脫硝效率之研究zh_TW
dc.language.isozh-TWzh-TW
DC.titleA study on the determination of COD and TN fraction and denitrification performance of wastewater treatment plantsen_US
DC.type博碩士論文zh_TW
DC.typethesisen_US
DC.publisherNational Central Universityen_US

若有論文相關問題,請聯絡國立中央大學圖書館推廣服務組 TEL:(03)422-7151轉57407,或E-mail聯絡  - 隱私權政策聲明