DC.contributor機械工程學系zh_TW
DC.creator郭修瑋zh_TW
DC.creatorShiou-Wei Kuoen_US
dc.date.accessioned2007-7-23T07:39:07Z
dc.date.available2007-7-23T07:39:07Z
dc.date.issued2007
dc.identifier.urihttp://ir.lib.ncu.edu.tw:88/thesis/view_etd.asp?URN=943203088
dc.contributor.department機械工程學系zh_TW
DC.description國立中央大學zh_TW
DC.descriptionNational Central Universityen_US
dc.description.abstract全人工髖關節置換手術後發生植入物鬆脫現象,主要的可能原因有二: 一. 因磨耗而產生的磨屑,使周圍骨組織產生骨溶解等,造成固定失敗。 二. 因為應力遮蔽效應而造成骨質流失。 在人工髖關節的植入手術後,使得原本人體髖臼與股骨球頭之間接觸面積變小,單位面積上所承受的負荷相對提高,造成人工關節髖臼-球接觸面的磨損情形比起原本的人體髖關節更為嚴重,而人工髖關節中,髖臼-球之間的磨耗行為是造成鬆脫的一個相當重要的因素,為了降低人工髖關節在置換後的鬆脫情形,了解磨耗的行為過程進而設法改善磨耗情形,延長植入物使用的壽命,已成為現今骨科醫師與醫學工程人員的一個重大的研究方向。 本研究希望藉由簡化運動模式來製造Two-station的模擬磨耗機台。針對在生理解剖學上髖關節實際運動的情形,去設計開發一部人工髖關節的雙軸向磨耗模擬試驗平台。藉由此人工髖關節模擬磨耗試驗平台,將所得到磨耗結果,結合臨床上的磨耗數據,試圖接近人工髖關節的各種條件,例如荷重、角度,磨耗率等,實驗的結果更可以作為往後設計改進磨耗平台與人工髖關節抗磨耗材料選取之重要依據,有助於未來人工髖關節相關的研究與發展。zh_TW
dc.description.abstractThere are two main factors causing loosening after total hip joint replacement. 1. The wear debris which causes osteoclasis will make implant fixation failed. 2. The osseous loss because of stress shielding. The hip joint replacement makes acetabular cup and femur head exposing area diminish, and makes the load on unit area higher. Wearing becomes more serious than original human hip joint’s wearing. However, the behavior of wearing is a quite important factor to prosthetic loosening. In order to reduce loosening after replacing of artificial hip join, understanding the behavior of wearing and try to improve implants have become a great direction of researching orthopedists and the direction of the researchers in biomedical engineering. This dissertation deal with using simplified motion cycles to design a two-station wear simulator. To develop a dual-axial dynamic hip joint wear simulator according to the motion of hip joint when exercising. Using the results of the wearing from the simulator, and combining with the clinical wearing data makes it close to various kinds of conditions of the artificial hip joint, such as the loading, angle, and wear rate etc. The results of the experiment can be regarded as the important basis of improving simulator and prosthetic design even more, and it also makes contribution to the research and development that the artificial hip joint is correlated with in the future.en_US
DC.subject簡化運動zh_TW
DC.subject磨耗機zh_TW
DC.subject髖關節zh_TW
DC.subjecttwo-stationen_US
DC.subjectsimplified motionen_US
DC.subjectsimulatoren_US
DC.subjecthip jointen_US
DC.title人工髖關節雙軸向動態磨耗試驗平台開發zh_TW
dc.language.isozh-TWzh-TW
DC.titleDevelopment of Dual-axial Dynamic Hip Joint Simulatoren_US
DC.type博碩士論文zh_TW
DC.typethesisen_US
DC.publisherNational Central Universityen_US